Search OEDI Data
Showing results 1 - 25 of 54.
Show
results per page.
Order by:
Available Now:
Research Areas
Accessibility
Data Type
Organization
Source
SiC Diode Test Data
Fabricated SiC diodes are tested in the temperature range of 300 degrees C to 600 degrees C.
Gilbert, G. Sandia National Laboratories
Aug 01, 2014
1 Resources
0 Stars
Publicly accessible
1 Resources
0 Stars
Publicly accessible
Preliminary performance of HT Datalink
Preliminary performance of high-temperature (HT) high-speed (HS) data link at room temperature over 5000 ft of wireline. The data shows ability of the data link to adapt by decreasing speed.
Cieslewski, G. Sandia National Laboratories
Feb 11, 2014
1 Resources
0 Stars
Publicly accessible
1 Resources
0 Stars
Publicly accessible
Laboratory Evaluation of EGS Shear Stimulation-Test 001
This is the results of an initial setup-shakedon test in order to develop the plumbing system for this test design. a cylinder of granite with offset holes was jacketed and subjected to confining pressure and low temperature (85C) and pore water pressure. Flow through the sample w...
Bauer, S. Sandia National Laboratories
Jul 29, 2014
1 Resources
0 Stars
Publicly accessible
1 Resources
0 Stars
Publicly accessible
Test Report for Detonation Velocity Measurements
Test report for detonation velocity measurements. A series of tests were conducted to determine reaction rate and general behavior of aluminum (AL) and magnesium (MG) powder mixtures (metalized explosives) with Bullseye double-base smokeless propellant. Given the indeterminate sen...
Grubelich, M. Sandia National Laboratories
Jan 13, 2014
1 Resources
0 Stars
Publicly accessible
1 Resources
0 Stars
Publicly accessible
Stability of Elastomers Subjected to Geothermal Well-Like Conditions
The aim of this study is to understand how commercially available elastomers perform under geothermal well-like conditions and make recommendations to the community based on these results. This poster highlights the mechanical performance of several elastomers (including EPDM, Vit...
Redline, E. et al Sandia National Laboratories
Aug 10, 2014
1 Resources
0 Stars
Publicly accessible
1 Resources
0 Stars
Publicly accessible
McGinness Hills Well 27A-10 Daily Drilling Report Data
This data should be used with the daily drilling record and other data which can be obtained from the contact listed below.
Knudsen, S. Sandia National Laboratories
Mar 25, 2014
2 Resources
0 Stars
Publicly accessible
2 Resources
0 Stars
Publicly accessible
USWAN Model Hindcast East Coast Regional Model (ECoRM)
Summary tables and plots of six International Electrotechnical Commission (IEC) wave parameters, including time series, scatter plots, and tables summarizing model performance.
Neary, V. Sandia National Laboratories
Sep 29, 2017
2 Resources
0 Stars
Publicly accessible
2 Resources
0 Stars
Publicly accessible
Hydroshear Simulation Lab Test 2, Additional Data Sheets
This file contains additional data for this test (hydroshear test 3.2). In this test a sample of granite with a pre-cut (man made fracture) is confined, heated and differential stress is applied. The max temperature in this this system development test is 95C. More test details ca...
Bauer, S. Sandia National Laboratories
Aug 01, 2014
2 Resources
0 Stars
Publicly accessible
2 Resources
0 Stars
Publicly accessible
High-Pressure Combustion and Deflagration-to-Detonation Transition in Ethylene/Nitrous Oxide Mixtures
In this paper, the combustion of nitrous oxide with a simple hydrocarbon, ethylene, at high initial pressures is investigated. A series of experiments were conducted using a stoichiometric C2H4-N2O mixture in a round, smooth-walled tube with initial pressures of 125 to 337 psi. ...
Grubelich, M. Sandia National Laboratories
Nov 01, 2013
1 Resources
0 Stars
Publicly accessible
1 Resources
0 Stars
Publicly accessible
Hydroshear Simulation Lab Test 2
This data file is for test 2. In this test a sample of granite with a pre-cut (man made fracture) is confined, heated and differential stress is applied. The max temperature in this this system development test is 95C. More test details can be found on the spreadsheets--note that ...
Bauer, S. Sandia National Laboratories
Aug 01, 2014
3 Resources
0 Stars
Publicly accessible
3 Resources
0 Stars
Publicly accessible
HT Flash and Tantalum Capacitor Report
Pushing the boundaries with geothermal tool development can often necessitate exceeding manufacturer specifications for temperature and pressure of individual circuit components. Detailed here are the efforts surrounding geothermal temperature characterization of commercially avai...
Cashion, A. and Cieslewski, G. Sandia National Laboratories
Oct 28, 2015
1 Resources
0 Stars
Publicly accessible
1 Resources
0 Stars
Publicly accessible
Centralizer for Use in Well Completions
Well completions are an integral part of providing safe, reliable and continuous access to underground resources such as oil, gas and geothermal resources. Completions are typically considered to be the final step of drilling engineering which includes processes such as setting c...
Su, J. Sandia National Laboratories
Apr 17, 2014
1 Resources
0 Stars
Publicly accessible
1 Resources
0 Stars
Publicly accessible
Extreme Significant Wave Heights for US Coastal Waters
Includes extreme significant wave heights, in meters, computed using peaks over threshold method on NOAA 30-year WWIII hindcast data. Extreme values for 5, 10, 25, 50, and 100 year return periods were computed. Sites cover US coastlines.
Column 1: Site identifier/name
Column 2: S...
Bredin, S. Sandia National Laboratories
Sep 01, 2016
1 Resources
0 Stars
Publicly accessible
1 Resources
0 Stars
Publicly accessible
MASK2B Initial Results from Wave Tank Test of Closed-Loop WEC Control
This dataset covers the MASK2B wave tank experiment focused on a more complete study of one degree of freedom (1DOF) control of the WEC was considered, including maximization of electrical power, multi-objective performance mapping, and implementation of a novel predictionless con...
Coe, R. et al Sandia National Laboratories
May 25, 2018
3 Resources
0 Stars
Publicly accessible
3 Resources
0 Stars
Publicly accessible
Testing for Controlled Rapid Pressurization
Borehole W1 is a NQ core hole drilled at our test site in Socorro. The rock is rhyolite. Borehole W1 which was used to test gas-gas explosive mixtures is 55 feet deep with casing (pinkish in the drawing) set to 35 feet. The model is a representation of the borehole and the hol...
Knudsen, S. Sandia National Laboratories
Sep 03, 2014
1 Resources
0 Stars
Publicly accessible
1 Resources
0 Stars
Publicly accessible
State Estimation for advanced control of wave energy converters
A report on state estimation for advanced control of wave energy converters (WECs), with supporting data models and slides from the overview presentation. The methods discussed are intended for use to enable real-time closed loop control of WECs.
Coe, R. and Bacelli, G. Sandia National Laboratories
Apr 25, 2017
6 Resources
0 Stars
Publicly accessible
6 Resources
0 Stars
Publicly accessible
Development of a Downhole Tracer and pH Measurement Instrument for Application in Geothermal Wells
Due the high temperature and pressure conditions found in geothermal wells, tracer studies designed to elucidate properties of geothermal reservoirs are traditionally conducted by pulling liquid samples from the wellhead. These samples are then sent off for analysis in a fixed lab...
Hess, R. et al Sandia National Laboratories
Sep 11, 2013
1 Resources
0 Stars
Publicly accessible
1 Resources
0 Stars
Publicly accessible
Applications of Fractured Continuum Model to Enhanced Geothermal System Heat Extraction Problems
This paper describes the applications of the fractured continuum model to the different enhanced geothermal systems reservoir conditions. The capability of the fractured continuum model to generate fracture characteristics expected in enhanced geothermal systems reservoir environm...
Kalinina, E. et al Sandia National Laboratories
May 06, 2014
1 Resources
0 Stars
Publicly accessible
1 Resources
0 Stars
Publicly accessible
High Temperature Chemical Sensing Tool: Preliminary pH and reference electrode test results
Project: High Temperature Chemical Sensing Tool for Distributed Mapping of Fracture Flow in EGS. Preliminary pH and reference electrode test results.
Cieslewski, G. Sandia National Laboratories
Sep 30, 2014
6 Resources
0 Stars
Publicly accessible
6 Resources
0 Stars
Publicly accessible
Modeling and Performance Data for Heaving Buoy Wave Energy Converter with a Compressible Degree of Freedom (CDOF)
Modeling and performance data in Matlab data file (.mat) containing 3 structures (WEC model, simRes_sr and simRes_fix), and a pdf document describing the model, the simulations, and the analysis that has been carried out.
Bacelli, G. Sandia National Laboratories
Sep 28, 2016
2 Resources
0 Stars
Publicly accessible
2 Resources
0 Stars
Publicly accessible
Experimental Testing of a Floating Oscillating Surge Wave Energy Converter at Hinsdale Wave Research Laboratory
In order to generate a public data set that can be used to validate Wave Energy Converter (WEC) numerical codes, such as WEC-Sim, Sandia National Laboratories led an experimental testing campaign of a 1:33 scale Floating Oscillating Surge Wave Energy Converter (FOSWEC) in the Dire...
Ruehl, K. et al Sandia National Laboratories
Jun 15, 2016
3 Resources
0 Stars
Publicly accessible
3 Resources
0 Stars
Publicly accessible
Advanced Geothermal Drilling and Logging Technologies
The objective of advanced drilling and logging technologies is to promote ways and means to reduce the cost of geothermal drilling through an integrated effort which involves developing an understanding of geothermal drilling and logging needs, elucidating best practices, and fost...
Raymond, D. et al Sandia National Laboratories
Dec 15, 2013
1 Resources
0 Stars
Publicly accessible
1 Resources
0 Stars
Publicly accessible
Microhole Test Data
Drilling results from the microhole project at the Sandia High Operating Temperature test facility. The project is seeking to help reduce the cost of exploration and monitoring of geothermal wells and formations by drilling smaller holes. The tests were part of a control algorith...
Su, J. Sandia National Laboratories
May 23, 2016
5 Resources
0 Stars
Publicly accessible
5 Resources
0 Stars
Publicly accessible
Physical and Numerical Modeling Open Source Files and Datasets for 1:6 Scale Reference Model 2 (RM2) Cross-Flow Turbine
This submission includes Github links to open source files and data sets, including the numerical model, CACTUS, input files, source code and output files, CAD files of the 1:6 scale model DOE's RM2 cross-flow turbine, power performance data and wake flow measurements from the 1:6...
Neary, V. Sandia National Laboratories
Jun 30, 2015
3 Resources
0 Stars
Publicly accessible
3 Resources
0 Stars
Publicly accessible
Advanced WEC Dynamics and Controls, Test 1
Numerous studies have shown that advanced control of a wave energy converter's (WEC's) power take off (PTO) can provide significant increases (on the order of 200-300%) in WEC energy absorption. Transitioning these control approaches from simplified paper studies to application in...
Coe, R. Sandia National Laboratories
Feb 26, 2016
3 Resources
0 Stars
Publicly accessible
3 Resources
0 Stars
Publicly accessible