UAE6 Wind Tunnel Tests Data UAE6 Sequence X Raw Data
**Overview**
Sequence X: Elevated RPM (F)
This test sequence used an upwind, rigid turbine with a 0° cone angle. The wind speed ranged
from 5 m/s to 12 m/s, and yaw angles of ±30° were obtained. The blade pitch angle was 3°. The
rotor rotated at 90 RPM. Blade pressure measur...
Fingersh, L. Wind Energy Technologies Office (WETO)
Nov 29, 2018
1 Resources
0 Stars
Publicly accessible
1 Resources
0 Stars
Publicly accessible
UAE6 Wind Tunnel Tests Data UAE6 Sequence 5 Raw Data
**Overview**
Sequence 5: Sweep Wind Speed (F,P)
This test sequence used an upwind, rigid turbine with a 0° cone angle. The wind speed was
ramped from 5 m/s to 25 m/s by the wind tunnel operator. This was repeated with a decreasing
ramp. The yaw angle was maintained at 0°. The ...
Fingersh, L. Wind Energy Technologies Office (WETO)
Nov 11, 2018
1 Resources
0 Stars
Publicly accessible
1 Resources
0 Stars
Publicly accessible
UAE6 Wind Tunnel Tests Data UAE6 Sequence 7 Raw Data
**Overview**
Sequence 7: Shroud Operating (P)
This test sequence used a downwind, rigid turbine with a 3.4° cone angle. The wind speed ranged
from 5 m/s to 25 m/s. Turntable angles from 0° to 30° were achieved, but the yaw error angle was
maintained at 0° by adjusting the na...
Fingersh, L. Wind Energy Technologies Office (WETO)
Nov 28, 2018
1 Resources
0 Stars
Publicly accessible
1 Resources
0 Stars
Publicly accessible
Visual Impact Assessment of the Existing Land-based Wind Turbine Fleet of the Contiguous United States
This data submission contains GIS raster datasets mapping the visual impacts of the land-based wind turbine fleet in the Contiguous United States (CONUS). Two datasets are included, each presenting a different quantification of visual impacts:
1. Cumulative visual magnitude, meas...
Gleason, M. et al National Renewable Energy Lab
Mar 19, 2024
3 Resources
0 Stars
Publicly accessible
3 Resources
0 Stars
Publicly accessible
Gearbox Reliability Collaborative Phase 3 Gearbox 2 Test
The National Renewable Energy Laboratory (NREL) Gearbox Reliability Collaborative (GRC) was established by the U.S. Department of Energy in 2006; its key goal is to understand the root causes of premature gearbox failures and improve their reliability. The GRC uses a combined gear...
Keller and RobbNational Renewable Energy Laboratory
May 02, 2016
17 Resources
0 Stars
Publicly accessible
17 Resources
0 Stars
Publicly accessible
UAE6 Wind Tunnel Tests Data UAE6 Sequence V Raw Data
**Overview**
Sequence V: Tip Plate (F)
This test sequence used an upwind, rigid turbine with a 0° cone angle. The wind speed ranged
from 5 m/s to 25 m/s, and the yaw angle was held at 0°. The blade pitch angle was 3°. The rotor
rotated at 72 RPM. Blade pressure measurements w...
Fingersh, L. Wind Energy Technologies Office (WETO)
Nov 28, 2018
1 Resources
0 Stars
Publicly accessible
1 Resources
0 Stars
Publicly accessible
UAE6 Wind Tunnel Tests Data UAE6 Sequence W Raw Data
**Overview**
Sequence W: Extended Blade (F)
This test sequence used an upwind, rigid turbine with a 0° cone angle. The wind speed ranged
from 5 m/s to 21 m/s, and the yaw angle was held at 0°. The blade pitch angle was 3°. The rotor
rotated at 72 RPM. Blade pressure measureme...
Fingersh, L. Wind Energy Technologies Office (WETO)
Nov 11, 2018
1 Resources
0 Stars
Publicly accessible
1 Resources
0 Stars
Publicly accessible
PNNL MET #1 pre-campaign / Raw Data
**Overview**
This dataset tests the data transfer and processing for a surface flux station, which includes low-speed weather information and high-speed sonic anemometer data.
Goldberger, L. Wind Energy Technologies Office (WETO)
Sep 22, 2015
1 Resources
0 Stars
Publicly accessible
1 Resources
0 Stars
Publicly accessible
UAE6 Wind Tunnel Tests Data UAE6 Sequence N Raw Data
**Overview**
Sequence N: Sin AOA, Rotating (P)
This sequence was designed to quantify the blade 3-D unsteady aerodynamic response in the
presence of rotational influences by varying blade pitch angle. Test sequence N used an upwind,
rigid turbine with a 0° cone angle. The wind ...
Fingersh, L. Wind Energy Technologies Office (WETO)
Nov 28, 2018
1 Resources
0 Stars
Publicly accessible
1 Resources
0 Stars
Publicly accessible
Sodar ND Scintec MFAS Wind Profiler with RASS, Rufus Reviewed Data
**Overview**
These data provide vertical mean profiles of wind and direction (30 min time step and 10 m range gate).
**Data Details**
Data averaged over an interval of 30 minutes.
Wind Direction is from Geographic North.
Time stamp is included in each data file.
Location: Jo...
Fernando, J. et al Wind Energy Technologies Office (WETO)
Dec 01, 2015
1 Resources
0 Stars
Publicly accessible
1 Resources
0 Stars
Publicly accessible
UAE6 Wind Tunnel Tests Data UAE6 Sequence O Raw Data
**Overview**
Sequence O: Sin AOA, Parked (P)
This sequence was designed to quantify the blade 3-D unsteady aerodynamic response in the
absence of rotational influences by varying blade pitch angle. This test sequence used an upwind,
rigid turbine with a 0° cone angle. The wind ...
Fingersh, L. Wind Energy Technologies Office (WETO)
Nov 28, 2018
1 Resources
0 Stars
Publicly accessible
1 Resources
0 Stars
Publicly accessible
UAE6 Wind Tunnel Tests Data UAE6 Sequence K Raw Data
**Overview**
Sequence K: Step AOA, Probes (P)
This sequence was designed to quantify the 3-D blade static angle-of-attack response in the
presence of rotational influences by varying the blade pitch angle. Sequence K used an upwind,
rigid turbine with a 0° cone angle. The wind ...
Fingersh, L. Wind Energy Technologies Office (WETO)
Nov 27, 2018
1 Resources
0 Stars
Publicly accessible
1 Resources
0 Stars
Publicly accessible
UAE6 Wind Tunnel Tests Data UAE6 Sequence L Raw Data
**Overview**
Sequence L: Step AOA, Parked (P)
This sequence was designed to quantify the 3-D blade static angle-of-attack response in the
absence of rotational influences by varying the blade pitch angle. This test sequence used an
upwind, rigid turbine with a 0° cone angle. Wi...
Fingersh, L. Wind Energy Technologies Office (WETO)
Nov 28, 2018
1 Resources
0 Stars
Publicly accessible
1 Resources
0 Stars
Publicly accessible
UAE6 Wind Tunnel Tests Data UAE6 Sequence 8 Raw Data
**Overview**
Sequences 8 and 9: Downwind Sonics (F,P) and Downwind Sonics Parked
(P)
This test sequence used an upwind, rigid turbine with a 0° cone angle. The wind speed ranged
from 5 m/s to 25 m/s. Yaw angles of 0° to 60° were achieved. The blade tip pitch was 3°. The
roto...
Fingersh, L. Wind Energy Technologies Office (WETO)
Nov 28, 2018
1 Resources
0 Stars
Publicly accessible
1 Resources
0 Stars
Publicly accessible
UAE6 Wind Tunnel Tests Data UAE6 Sequence 9 Raw Data
**Overview**
Sequences 8 and 9: Downwind Sonics (F,P) and Downwind Sonics Parked
(P)
This test sequence used an upwind, rigid turbine with a 0° cone angle. The wind speed ranged
from 5 m/s to 25 m/s. Yaw angles of 0° to 60° were achieved. The blade tip pitch was 3°. The
roto...
Fingersh, L. Wind Energy Technologies Office (WETO)
Nov 28, 2018
1 Resources
0 Stars
Publicly accessible
1 Resources
0 Stars
Publicly accessible
UAE6 Wind Tunnel Tests Data UAE6 Sequence E Raw Data
**Overview**
Sequence E: Yaw Releases (P)
This test sequence used a downwind, rigid turbine with a 3.4° cone angle. The wind speeds
ranged from 7 m/s to 17 m/s. Initial yaw angles of ±90° were achieved. The blade tip pitch was
3°. The rotor rotated at 72 RPM. Blade and probe...
Fingersh, L. Wind Energy Technologies Office (WETO)
Nov 27, 2018
1 Resources
0 Stars
Publicly accessible
1 Resources
0 Stars
Publicly accessible
UAE6 Wind Tunnel Tests Data UAE6 Sequence R Raw Data
**Overview**
Sequence R: Step AOA, No Probes (P)
This sequence was designed to quantify the effect of the five-hole probes on the 3-D blade static
angle-of-attack response in the presence of rotational influences by repeating Sequence K without
five-hole probes. This test sequen...
Fingersh, L. Wind Energy Technologies Office (WETO)
Nov 28, 2018
1 Resources
0 Stars
Publicly accessible
1 Resources
0 Stars
Publicly accessible
Sodar ND Scintec MFAS Wind Profiler with RASS, Rufus Raw Data
**Overview**
The data provide vertical mean profiles of wind and temperature.
**Data Details**
* Data averaged over an interval of 30 minutes.
* Time stamp is included in each data file.
* Location: John Day/Rufus Water Treatment Plant (45.690842,-120.745751).
* Site Elevat...
Fernando, J. et al Wind Energy Technologies Office (WETO)
Dec 01, 2015
1 Resources
0 Stars
Publicly accessible
1 Resources
0 Stars
Publicly accessible
Sodar NREL Scintec MFAS Wind Profiler, Decker Ranch Airstrip Raw Data
**Overview**
The dataset includes 15-minute average wind speed and direction records from 30 m to 330 m above ground level (AGL) in 10-m range gates. Data were collected by a Scintec MFAS wind profiler installed at the Decker Ranch in Oregon, about 4.4 km southeast of Kent, Ore.,...
Jager, D. and Scott, G. Wind Energy Technologies Office (WETO)
Oct 27, 2015
1 Resources
0 Stars
Publicly accessible
1 Resources
0 Stars
Publicly accessible
Sodar NREL Scintec MFAS Wind Profiler, Decker Ranch Airstrip Reviewed Data
**Overview**
The dataset includes 15-minute average wind speed and direction records from 30 m to 330 m above ground level (AGL) in 10-m range gates. Data were collected by a Scintec MFAS wind profiler installed at the Decker Ranch in Oregon, about 4.4 km southeast of Kent, Ore.,...
Jager, D. and Scott, G. Wind Energy Technologies Office (WETO)
Nov 19, 2015
1 Resources
0 Stars
Publicly accessible
1 Resources
0 Stars
Publicly accessible
Sodar NREL Scintex SFAS Wind Profiler, Condon Raw Data
**Overview**
The dataset includes 15-minute average wind speed and direction records from 10 m to 250 m above ground level (AGL) in 5-m range gates. Data were collected by a Scintec SFAS wind profiler installed at the Condon State Airport in Oregon, about 1.8 km northeast of the ...
Scott, G. and Jager, D. Wind Energy Technologies Office (WETO)
Nov 19, 2015
1 Resources
0 Stars
Publicly accessible
1 Resources
0 Stars
Publicly accessible
Sodar NREL Scintex SFAS Wind Profiler, Condon Reviewed Data
**Overview**
The dataset includes 15-minute average wind speed and direction records from 10 m to 250 m above ground level (AGL) in 5-m range gates. Data were collected by a Scintec SFAS wind profiler installed at the Condon State Airport in Oregon, about 1.8 km northeast of the ...
Scott, G. and Jager, D. Wind Energy Technologies Office (WETO)
Nov 19, 2015
1 Resources
0 Stars
Publicly accessible
1 Resources
0 Stars
Publicly accessible
Lidar HilFlowS LLNL ZephIR300 WOP Processed Data
**Overview**
The ZephIR300 is a continuous wave LIDAR with a range of 10 m to 300 m. During HilFlowS the ZephIR300 was programmed to measure from 10 m to 150 m. In addition, the ZephIR300 provided a measurement at 1 m height using an onboard meteorological sensor. The ZephIR300 ...
Wharton, S. and , . Wind Energy Technologies Office (WETO)
Jul 07, 2019
1 Resources
0 Stars
Publicly accessible
1 Resources
0 Stars
Publicly accessible
Lidar HilFlowS LLNL ZephIR300 MOP Processed Data
**Overview**
The ZephIR300 is a continuous wave LIDAR with a range of 10 m to 300 m. During HilFlowS the ZephIR300 was programmed to measure from 10 m to 150 m. In addition, the ZephIR300 provided a measurement at 1 m height using an onboard meteorological sensor. The ZephIR300 ...
Wharton, S. and , . Wind Energy Technologies Office (WETO)
Jul 07, 2019
1 Resources
0 Stars
Publicly accessible
1 Resources
0 Stars
Publicly accessible
Renewable Energy Finance Tracking Initiative 2009-2010
This dataset highlights key financing terms for U.S. renewable energy projects that closed financing between Q3 2009 and Q3 2010. Information tracked includes debt interest rates, equity returns, financial structure applied, PPA duration, and other information.
This dataset comes...
Kreycik, C. National Renewable Energy Laboratory
Nov 25, 2014
7 Resources
0 Stars
In curation
7 Resources
0 Stars
In curation