National Renewable Energy Laboratory/Habitat for Humanity Zero Energy Home: A Cold Climate Case Study for Affordable Zero Energy Homes
The design of this 1,280-square-foot, three-bedroom Habitat for Humanity of Metro Denver zero energy home carefully combines envelope efficiency, efficient equipment, appliances and lighting, and passive and active solar features to reach the zero energy goal. The home was designe...
Norton, P. et al National Renewable Energy Laboratory
Jul 21, 2016
4 Resources
0 Stars
Publicly accessible
4 Resources
0 Stars
Publicly accessible
Sacramento Deep Energy Retrofit (DER) Home Study
This project was part of the Sacramento Municipal Utility District (SMUD) Deep Energy Retrofit (DER) Project which included several other homes in addition to the the subject of this study. Some of the reports and presentations included in this dataset cover the whole DER project....
Keesee, M. Sacramento Municipal Utility District
Aug 10, 2016
8 Resources
0 Stars
Publicly accessible
8 Resources
0 Stars
Publicly accessible
Conway St Apartments Olive Street Development
In Greenfield, Massachusetts, Olive Street Development transformed an old elementary school building into 12 high-end rental apartments. The developer aimed to get as close to net-zero performance as practical, installing: (1) R-30 high-density spray foam against the brick walls (...
Aldrich, R. and Williamson, J. Steven Winter Associates of the Consortium for Advanced Residential Buildings
Apr 27, 2016
2 Resources
0 Stars
In curation
2 Resources
0 Stars
In curation
BuildingsBench: A Large-Scale Dataset of 900K Buildings and Benchmark for Short-Term Load Forecasting
The BuildingsBench datasets consist of:
Buildings-900K: A large-scale dataset of 900K buildings for pretraining models on the task of short-term load forecasting (STLF). Buildings-900K is statistically representative of the entire U.S. building stock.
7 real residential and com...
Emami, P. and Graf, P. National Renewable Energy Laboratory
Dec 31, 2018
6 Resources
0 Stars
Publicly accessible
6 Resources
0 Stars
Publicly accessible
Demand-Side Grid (dsgrid) Highly-resolved, Long-term Energy Demand Projections for the Contiguous United States: DECARB Scenarios
Input and compiled datasets describing projected energy use by sector and for the power sector as a whole. Data are developed by a multi-national lab team as part of the U.S. Department of Energy (DOE) Energy Efficiency and Renewable Energy (EERE) Office's DECARB project.
Hale, E. et al National Renewable Energy Laboratory
Jul 01, 2024
2 Resources
0 Stars
In progress
2 Resources
0 Stars
In progress
Mini-Split Heat Pump Evaluation and Zero Energy Ready Home Support
This project was created from a partnership between the U.S. Department of Energy's (DOE's) Building America research team, IBACOS, Inc., and a production builder of high-performance homes called Imagine Homes, which is located in San Antonio, Texas-a hot-humid climate. The primar...
Rapport, A. and Herk, A. Ibacos Innovation
Apr 27, 2016
5 Resources
0 Stars
Publicly accessible
5 Resources
0 Stars
Publicly accessible
Evaluating an Exterior Insulation and Finish System for Deep Energy Retrofits
This report provides a case study of a deep energy retrofit using a site-applied exterior insulation and finish system (EIFS). Prefabricated EIFS panels are also discussed as a potential wall insulation retrofit solution. EIFSs are common in new and retrofit commercial constructio...
Dentz, J. and Podorson, D. The Levy Partnership, Inc Systems Building Research Alliance
Apr 27, 2016
2 Resources
0 Stars
Publicly accessible
2 Resources
0 Stars
Publicly accessible
Commercial and Residential Hourly Load Profiles for all TMY3 Locations in the United States
Note: This dataset has been superseded by the dataset found at "End-Use Load Profiles for the U.S. Building Stock" (submission 4520; linked in the submission resources), which is a comprehensive and validated representation of hourly load profiles in the U.S. commercial and reside...
Ong, S. and Clark, N. National Renewable Energy Laboratory
Nov 25, 2014
22 Resources
0 Stars
Curated
22 Resources
0 Stars
Curated
Field Testing of Compartmentalization Methods for Multifamily Construction Washington DC
BSC TO5 Task 2.1 Field Testing of Compartmentalization Methods for Multifamily Construction Capitol Heights, MD 20743
A building comprising five vertical townhome units was built in the Washington, D.C., area; the townhomes were three-story slab-on-grade units (1700-2000 ft2) wit...
Ueno, K. and Lstiburek, J. Building Science Corporation
Apr 27, 2016
22 Resources
0 Stars
Publicly accessible
22 Resources
0 Stars
Publicly accessible
State Energy Efficient Appliance Rebate Program (SEEARP) Reports
The State Energy Efficient Appliance Rebate Program (SEEARP) reports database includes rebate reports (xls) and summary factsheets (pdf) from states and territories that participated in SEEARP. With funding provided by the American Recovery and Reinvestment Act of 2009 (ARRA), the...
Hoffmeyer, D. Office of Energy Efficiency and Renewable Energy
Jun 18, 2015
5 Resources
0 Stars
Publicly accessible
5 Resources
0 Stars
Publicly accessible
Evaluation of the Performance of Houses With and Without Supplemental Dehumidification in a Hot-Humid Climate
Understanding indoor humidity conditions in low energy homes in hot-humid climates is critical to promoting long term occupant comfort, indoor air quality and building durability. The results of this study were expected to inform the residential building community on whether suppl...
Kerrigan, P. and Norton, P. National Renewable Energy Laboratory
Apr 27, 2016
7 Resources
0 Stars
Publicly accessible
7 Resources
0 Stars
Publicly accessible
NorthernSTAR Project Overcoat: Exterior Insulation Strategies for 1.5-Story Roof Applications in Cold Climates
This is a repository for all NorthernSTAR Overcoat insulation retrofit projects. Both houses received Overcoat insulation retrofit on roof only, performed by Cocoon Insulation.
1 St. Louis Park house St. Louis Park, MN
2 Edina house Edina, MN
In this second study, the team wishe...
Jacobson, R. et al University of Minnesota NorthernSTAR Building America Partnership
Apr 27, 2016
10 Resources
0 Stars
Publicly accessible
10 Resources
0 Stars
Publicly accessible
Public Housing: A Tailored Approach to Energy Retrofits Raleigh
More than 1 million U.S. Department of Housing and Urban Development-supported public housing units provide rental housing for eligible low-income families across the country. These units range from scattered single-family houses to high-rise apartments. In this project, the Advan...
Dentz, J. et al The Levy Partnership, Inc Systems Building Research Alliance
Apr 27, 2016
7 Resources
0 Stars
Publicly accessible
7 Resources
0 Stars
Publicly accessible
Monitoring of Double-Stud Wall Moisture Conditions in the Northeast
BSC TO5 Task 2.2 Monitoring of Double Stud Wall Moisture Conditions in the Northeast
Field test data available for wood moisture contents, temperature, and relative humidity.
STRUCTURE House Devens, MA 01432
Three double-stud assemblies were compared: 12-in. ocSPF, 12-in. cellulo...
Ueno, K. Building Science Corporation
Apr 27, 2016
2 Resources
0 Stars
Publicly accessible
2 Resources
0 Stars
Publicly accessible
Analysis of Joist Masonry Moisture Content Monitoring
BSC TO5 Task 7.2 Analysis of Joist Masonry Moisture Content Monitoring
House Lawrence, MA 01840
This work involved the field monitoring of embedded wood joist ends in a solid brick building in zone 5A that was retrofitted with interior insulation. Eleven joists throughout the bui...
Ueno, K. Building Science Corporation
Apr 27, 2016
3 Resources
0 Stars
Publicly accessible
3 Resources
0 Stars
Publicly accessible
Measure Guideline: Deep Energy Enclosure Retrofit for Interior Insulation of Masonry Walls and Flat Roofs
Measure Guideline: Deep Energy Enclosure Retrofit for Zero Energy Ready House Flat Roofs
BSC TO5 Task 7.4 Deep Energy Enclosure Retrofit (DEER) for Interior Insulation of Masonry Walls
Lawrence, MA 01840
This Measure Guideline describes a deep energy enclosure retrofit solution ...
Musunuru, S. et al Building Science Corporation
Apr 27, 2016
5 Resources
0 Stars
Publicly accessible
5 Resources
0 Stars
Publicly accessible
Measured Performance of a Varied Airflow Small-Diameter Duct System
In this study, researchers with the U.S. Department of Energy's Building America team IBACOS built on research previously done in two new-construction unoccupied test houses-one in Pittsburgh, Pennsylvania (Poerschke and Stecher 2014) and one in Fresno, California (Stecher and Poe...
Poerschke, A. Ibacos Innovation
Apr 27, 2016
5 Resources
0 Stars
Publicly accessible
5 Resources
0 Stars
Publicly accessible
Low-Income Energy Affordability Data LEAD Tool 2018 Update
The Low-Income Energy Affordability Data (LEAD) Tool was created by the Better Building's Clean Energy for Low Income Communities Accelerator (CELICA) to help state and local partners understand housing and energy characteristics for the low and moderate-income (LMI) communities t...
Ma, O. U.S. Department of Energy, Office of Energy Efficiency and Renewable Energy
Jul 01, 2020
55 Resources
0 Stars
Publicly accessible
55 Resources
0 Stars
Publicly accessible
Comfort in High-Performance Homes in a Hot-Humid Climate
TO5 2.3.2: Large-Scale Temperature Study
Although space-conditioning systems are required to meet standards such as those in the Air Conditioning Contractors of America (ACCA) Manual RS (Rutkowski 1997) and the ASHRAE Standard 55 (ASHRAE 2013) comfort criteria, little is known ab...
Poerschke, A. and Beach, R. Ibacos Innovation
Apr 27, 2016
3 Resources
0 Stars
Publicly accessible
3 Resources
0 Stars
Publicly accessible
Greenbuilt Construction Energy Efficiency Retrofit House Demonstration Sacramento
One of the homes that was part of Sacramento Municipal Utility District's (SMUD) Energy Efficiency Retrofit Demonstration (EERD) project was a 1980's era home in Fair Oaks, California, referred to as the Greenbuilt house, as Greenbuilt Construction completed the retrofit of the h...
Sparn, B. et al Mountain Energy Partnership
Aug 27, 2018
8 Resources
0 Stars
Publicly accessible
8 Resources
0 Stars
Publicly accessible