Search OEDI Data
Showing results 51 - 75 of 109.
Show
results per page.
Order by:
Available Now:
Research Areas
Accessibility
Data Type
Organization
Source
Thermostatic Radiator Valve Evaluation and Demonstration
A large stock of multifamily buildings in the Northeast and Midwest uses hot water or steam for space heating. Typically, residents do not pay for heat directly (i.e., heating fuel serves a central plant and use is not submetered). Losses from these systems are typically high, and...
Dentz, J. and Ansanelli, E. The Levy Partnership, Inc Systems Building Research Alliance
Apr 27, 2016
2 Resources
0 Stars
Publicly accessible
2 Resources
0 Stars
Publicly accessible
Field Testing of an Unvented Roof with Fibrous Insulation, Tiles, and Vapor Diffusion Venting
BSC TO5 Task 2.5 Field Testing of an Un-vented Roof with Fibrous Insulation and Tiles Winter Park, FL 32789
Field test data available for wood moisture contents, temperature, and relative humidity.
Un-vented roofs (aka cathedral-ized attics) are an established presence in Florida...
Ueno, K. and Lstiburek, J. Building Science Corporation
Apr 27, 2016
2 Resources
0 Stars
Publicly accessible
2 Resources
0 Stars
Publicly accessible
Field Testing Unvented Roofs with Asphalt Shingles in Cold and Hot-humid Climates
BSC TO5 Task 7.1 Field Testing Unvented Roofs with Asphalt Shingles in Cold Climates Bolingbrook, IL 60440
BSC TO5 Task 7.1 Field Testing Unvented Roofs with Asphalt Shingles in Hot-Humid Climates Friendswood, TX 77546
To understand the long-term moisture performance of unvented ...
Ueno, K. and Lstiburek, J. Building Science Corporation
Apr 27, 2016
3 Resources
0 Stars
Publicly accessible
3 Resources
0 Stars
Publicly accessible
Performance and Costs of Ductless Heat Pumps in Marine-Climate High-Performance Homes Habitat for Humanity The Woods
The Washington State University (WSU) Energy Program's Building America (BA) team conducted a case study of a high-performance affordable housing community: The Woods (Figure 1). This BA effort is part of a larger-scale study of 30 homes funded from 2013-2016 by Tacoma Public Util...
Lubliner, M. et al Washington State University
Apr 27, 2016
8 Resources
0 Stars
Publicly accessible
8 Resources
0 Stars
Publicly accessible
Approaches to 30% Energy Savings at the Community Scale in the Hot-Humid Climate
The Building America Partnership for Improved Residential Construction, formerly the Building America Industrialized Housing Partnership, has worked with several community-scale builders within the hot-humid climate zone to improve performance of production-, or community-scale, h...
Beal, D. et al University of Central Florida Florida Solar Energy Center
Apr 27, 2016
9 Resources
0 Stars
Publicly accessible
9 Resources
0 Stars
Publicly accessible
EcoVillage: A Net Zero Energy Ready Community Ithaca Crawlspace
The U.S. Department of Energy's (DOE) Building America team, Consortium for Residential Buildings (CARB), is working with the EcoVillage cohousing community in Ithaca, New York, on the Third Residential EcoVillage Experience neighborhood. This community-scale project consists of 4...
Arena, L. et al Steven Winter Associates of the Consortium for Advanced Residential Buildings
Apr 27, 2016
3 Resources
0 Stars
Publicly accessible
3 Resources
0 Stars
Publicly accessible
Curated Modeled Fault Data Set
The curated fault model simulation data set consists of tagged and fully-described time series representing simulated faults for the AFDD test building (ORNLs Flexible Research Platform (FRP)), including baseline performance, faulty performance, and corresponding energy impact. A ...
Kim, J. and Leach, M. National Renewable Energy Laboratory
Jun 24, 2019
7 Resources
0 Stars
Curated
7 Resources
0 Stars
Curated
Analysis of Joist Masonry Moisture Content Monitoring
BSC TO5 Task 7.2 Analysis of Joist Masonry Moisture Content Monitoring
House Lawrence, MA 01840
This work involved the field monitoring of embedded wood joist ends in a solid brick building in zone 5A that was retrofitted with interior insulation. Eleven joists throughout the bui...
Ueno, K. Building Science Corporation
Apr 27, 2016
3 Resources
0 Stars
Publicly accessible
3 Resources
0 Stars
Publicly accessible
Brookfield Homes Passive House Performance Evaluation
TO4 3.1.3: Brookfield Homes Short-Term Results
TO5 3.1.3: Brookfield Passive House Monitoring
To further define its market position on high performance homebuilding, Brookfield worked with IBACOS and the Building America program to design and construct a Passive House (PH) certif...
Beach, R. et al Ibacos Innovation
Apr 27, 2016
4 Resources
0 Stars
Publicly accessible
4 Resources
0 Stars
Publicly accessible
NorthernSTAR 1.5-Story Demonstration House of Cold Climate Solutions for Affordable Housing
This is a NorthernSTAR renovation project for Urban Homeworks incorporating installation of a combination space and water heater, Overcoat insulation retrofit on the roof, and Excavationless foundation insulation retrofit.
STRUCTURE 1401 North 16th Ave Minneapolis, MN 55411
Var...
Jacobson, R. et al University of Minnesota NorthernSTAR Building America Partnership
Apr 27, 2016
12 Resources
0 Stars
Publicly accessible
12 Resources
0 Stars
Publicly accessible
NorthernSTAR Project Overcoat: Exterior Insulation Strategies for 1.5-Story Roof Applications in Cold Climates
This is a repository for all NorthernSTAR Overcoat insulation retrofit projects. Both houses received Overcoat insulation retrofit on roof only, performed by Cocoon Insulation.
1 St. Louis Park house St. Louis Park, MN
2 Edina house Edina, MN
In this second study, the team wishe...
Jacobson, R. et al University of Minnesota NorthernSTAR Building America Partnership
Apr 27, 2016
10 Resources
0 Stars
Publicly accessible
10 Resources
0 Stars
Publicly accessible
Evaluation of the U.S. Department of Energy Challenge Home Program Certification of Production Builders Chicago, IL and Devens, MA
TO4 Task 3.1 K Hovnanian Chicago, IL
DOE Challenge Home Program Certified
Home Constructed and Verified
Specifications
DOE Challenge Home
Building envelope
Ceiling R-49 blown fiberglass, Grade I
Walls 2x4 framing @ 16 o.c. with R-13 fiberglass batts, Grade I
and 1"" R-5 extrude...
Loomis, H. and Kerrigan, P. Building Science Corporation
Apr 27, 2016
6 Resources
0 Stars
Publicly accessible
6 Resources
0 Stars
Publicly accessible
Buildings Energy Data Book
The Building Energy Data Book (2011) is a compendium of data from a variety of data sets and includes statistics on residential and commercial building energy consumption. Data tables contain statistics related to construction, building technologies, energy consumption, and buildi...
Mayernik, J. and (EERE), O. National Renewable Energy Laboratory
Jun 11, 2015
4 Resources
0 Stars
In curation
4 Resources
0 Stars
In curation
Buildings Performance Database
The Buildings Performance Database (BPD) unlocks the power of building energy performance data. The platform enables users to perform statistical analysis on an anonymous dataset of tens of thousands of commercial and residential buildings from across the country. Users can compar...
Contact, B. and (EERE), O. Office of Energy Efficiency & Renewable Energy
Nov 25, 2014
2 Resources
0 Stars
In curation
2 Resources
0 Stars
In curation
Hathaway Solar Patriot house
This Dataset contains field research raw data, analysis spreadsheet, photos, and final report from the Hathaway Solar Patriot House Building America Case Study project.
Norton, P. National Renewable Energy Laboratory
Jun 09, 2016
6 Resources
0 Stars
In curation
6 Resources
0 Stars
In curation
Greenbelt Homes Pilot Program: Summary of Building Envelope Retrofits, Planned HVAC Equipment Upgrades, and Energy Savings
In fall 2010, Greenbelt Homes, Inc. (GHI) a 1,566-home cooperative of circa 1930-1940 homes in Greenbelt, Maryland, undertook a multiyear pilot energy efficiency retrofit project. GHI established this pilot project as a basis for decision making for the rollout of a decade-long co...
Mallay, D. et al Home Innovation Research Labs National Association of Home Builders
Jul 21, 2016
4 Resources
0 Stars
Publicly accessible
4 Resources
0 Stars
Publicly accessible
Evaluating an Exterior Insulation and Finish System for Deep Energy Retrofits
This report provides a case study of a deep energy retrofit using a site-applied exterior insulation and finish system (EIFS). Prefabricated EIFS panels are also discussed as a potential wall insulation retrofit solution. EIFSs are common in new and retrofit commercial constructio...
Dentz, J. and Podorson, D. The Levy Partnership, Inc Systems Building Research Alliance
Apr 27, 2016
2 Resources
0 Stars
Publicly accessible
2 Resources
0 Stars
Publicly accessible
NREL RSF Measured Data 2011
Modern buildings are complex energy systems that must be controlled for energy efficiency. The Research Support Facility (RSF) at the National Renewable Energy Laboratory (NREL) has hundreds of controllers computers that communicate with the building's various control systems to...
Sheppy, M. et al National Renewable Energy Laboratory
Nov 25, 2014
2 Resources
0 Stars
Publicly accessible
2 Resources
0 Stars
Publicly accessible
Modeled Performance of the Hathaway Solar Patriot house Washington D.C
This Dataset contains field research raw data, analysis spreadsheet, photos, and final report from the Hathaway Solar Patriot House Building America Case Study project.
This dataset details the monitored and modeled performance of a solar home outside of Washington, D.C. We model...
Norton, P. et al National Renewable Energy Laboratory
Jun 20, 2016
5 Resources
0 Stars
Publicly accessible
5 Resources
0 Stars
Publicly accessible
Long-term electricity and gas consumption for LBNL Building 74
15 minute electricity and 5 minute natural gas consumption data for Building 74 on the Lawrence Berkeley National Lab campus.
Langevin, J. Lawrence Berkeley National Laboratory
Jul 20, 2015
2 Resources
1 Stars
In curation
2 Resources
1 Stars
In curation
Phased Retrofits in Existing Homes in Florida Phase I: Shallow and Deep Retrofits
The U.S. Department of Energy's Building America research team Building America Partnership for Improved Residential Construction is collaborating with Florida Power & Light (FPL) to conduct a phased residential energy-efficiency retrofit program. This research seeks to establish ...
Beal, D. et al University of Central Florida Florida Solar Energy Center
Apr 27, 2016
10 Resources
0 Stars
Publicly accessible
10 Resources
0 Stars
Publicly accessible
Evaluation of the Performance of Houses With and Without Supplemental Dehumidification in a Hot-Humid Climate
Understanding indoor humidity conditions in low energy homes in hot-humid climates is critical to promoting long term occupant comfort, indoor air quality and building durability. The results of this study were expected to inform the residential building community on whether suppl...
Kerrigan, P. and Norton, P. National Renewable Energy Laboratory
Apr 27, 2016
7 Resources
0 Stars
Publicly accessible
7 Resources
0 Stars
Publicly accessible
Comparative Performance of Four Prototype Mechanical Building Cooling Systems in a Desert Climate
Data and result of approximately fifteen months of monitoring of four houses located in the desert climate of Borrego Springs, California. Four houses were constructed using identical floor plans but differing wall materials, and different cooling systems that were designed to red...
Springer, D. et al Davis Energy
Jul 20, 2016
9 Resources
0 Stars
Curated
9 Resources
0 Stars
Curated
Retrofitting a 1960s Split-Level Cold-Climate Home
The U.S. Department of Energy Building America research team Consortium for Advanced Residential Buildings (CARB) partnered with Preferred Builders, a previous CARB partner and builder of the Performance House (DOE 2013) and the owners of a 1960s split-level home in Westport, Conn...
Puttagunta, S. Steven Winter Associates of the Consortium for Advanced Residential Buildings
Apr 27, 2016
3 Resources
0 Stars
Publicly accessible
3 Resources
0 Stars
Publicly accessible
Moisture Risk in Unvented Attics Due to Air Leakage Paths Minneapolis Minnesota
IBACOS completed an initial analysis of moisture damage potential in an unvented attic insulated with closed-cell spray polyurethane foam. To complete this analysis, the research team collected field data, used computational fluid dynamics to quantify the airflow rates through ind...
Rapport, A. et al Ibacos Innovation
Apr 27, 2016
6 Resources
0 Stars
Publicly accessible
6 Resources
0 Stars
Publicly accessible