Modular Zero Energy Ready Homes: Bright Built Maine
Kaplan Thompson Architects (KTA) has specialized in sustainable, energy-efficient buildings, and they have designed several custom, zero-energy homes in New England. These zero-energy projects have generally been high-end, custom homes with budgets that could accommodate advanced ...
Aldrich, R. and Butterfield, K. Steven Winter Associates of the Consortium for Advanced Residential Buildings
Apr 27, 2016
2 Resources
0 Stars
Publicly accessible
2 Resources
0 Stars
Publicly accessible
Field Testing Unvented Roofs with Asphalt Shingles in Cold and Hot-humid Climates
BSC TO5 Task 7.1 Field Testing Unvented Roofs with Asphalt Shingles in Cold Climates Bolingbrook, IL 60440
BSC TO5 Task 7.1 Field Testing Unvented Roofs with Asphalt Shingles in Hot-Humid Climates Friendswood, TX 77546
To understand the long-term moisture performance of unvented ...
Ueno, K. and Lstiburek, J. Building Science Corporation
Apr 27, 2016
3 Resources
0 Stars
Publicly accessible
3 Resources
0 Stars
Publicly accessible
The Performance House: A Cold Climate Challenge Home Old Greenwich
Working with builder partners on test homes allows for vetting of whole-house building strategies to eliminate any potential unintended consequences prior to implementing these solution packages on a production scale. To support this research, the Consortium for Advanced Residenti...
Williamson, J. et al Steven Winter Associates of the Consortium for Advanced Residential Buildings
Apr 27, 2016
4 Resources
0 Stars
Publicly accessible
4 Resources
0 Stars
Publicly accessible
Demand Response Across the Continental US for 2006
This project estimates hourly demand response availability across the continental U.S. for the year 2006. The resulting data set is disaggregated by balancing authority area, end use, and grid application. End uses include 14 categories across residential, commercial, industrial a...
Ma, S. Office of Energy Efficiency and Renewable Energy
Sep 12, 2016
6 Resources
0 Stars
Publicly accessible
6 Resources
0 Stars
Publicly accessible
ResStock: Annual Baseline Results with Component Loads
The ResStock Analysis Tool was developed by NREL with support from the U.S. Department of Energy to provide a new approach to large-scale residential analysis by combining large public and private data sources, statistical sampling, detailed sub hourly building simulations, and hi...
Speake, A. et al National Renewable Energy Lab
Mar 03, 2023
6 Resources
0 Stars
Curated
6 Resources
0 Stars
Curated
Field Testing of an Unvented Roof with Fibrous Insulation, Tiles, and Vapor Diffusion Venting
BSC TO5 Task 2.5 Field Testing of an Un-vented Roof with Fibrous Insulation and Tiles Winter Park, FL 32789
Field test data available for wood moisture contents, temperature, and relative humidity.
Un-vented roofs (aka cathedral-ized attics) are an established presence in Florida...
Ueno, K. and Lstiburek, J. Building Science Corporation
Apr 27, 2016
2 Resources
0 Stars
Publicly accessible
2 Resources
0 Stars
Publicly accessible
National Renewable Energy Laboratory/Habitat for Humanity Zero Energy Home: A Cold Climate Case Study for Affordable Zero Energy Homes
The design of this 1,280-square-foot, three-bedroom Habitat for Humanity of Metro Denver zero energy home carefully combines envelope efficiency, efficient equipment, appliances and lighting, and passive and active solar features to reach the zero energy goal. The home was designe...
Norton, P. et al National Renewable Energy Laboratory
Jul 21, 2016
4 Resources
0 Stars
Publicly accessible
4 Resources
0 Stars
Publicly accessible
Approaches to 30% Energy Savings at the Community Scale in the Hot-Humid Climate
The Building America Partnership for Improved Residential Construction, formerly the Building America Industrialized Housing Partnership, has worked with several community-scale builders within the hot-humid climate zone to improve performance of production-, or community-scale, h...
Beal, D. et al University of Central Florida Florida Solar Energy Center
Apr 27, 2016
9 Resources
0 Stars
Publicly accessible
9 Resources
0 Stars
Publicly accessible
Energy Innovation Portal
About the Energy Innovation Portal. The Energy Innovation Portal is a one-stop resource for Department of Energy (DOE) Energy Efficiency and Renewable Energy (EERE) technologies. This application enables users to locate technologies developed with DOE funding and available for lic...
Webmaster, . and Laboratory, N. National Renewable Energy Laboratory
Nov 25, 2014
1 Resources
0 Stars
In curation
1 Resources
0 Stars
In curation
Monitoring of Double-Stud Wall Moisture Conditions in the Northeast
BSC TO5 Task 2.2 Monitoring of Double Stud Wall Moisture Conditions in the Northeast
Field test data available for wood moisture contents, temperature, and relative humidity.
STRUCTURE House Devens, MA 01432
Three double-stud assemblies were compared: 12-in. ocSPF, 12-in. cellulo...
Ueno, K. Building Science Corporation
Apr 27, 2016
2 Resources
0 Stars
Publicly accessible
2 Resources
0 Stars
Publicly accessible
Mechanical Ventilation and Indoor Air Quality in Recently Constructed U.S. Homes in Marine and Cold-Dry Climates Data from Building America Project
Data were collected to characterize whole-house mechanical ventilation (WHMV) and indoor air quality (IAQ) in 55 homes in the Marine climate of Oregon and Cold-Dry climate of Colorado in the U.S. Sixteen homes were monitored for two weeks, with and without WHMV operating. Ventilat...
Zhao, H. et al Lawrence Berkeley National Laboratory
Mar 22, 2023
2 Resources
0 Stars
Publicly accessible
2 Resources
0 Stars
Publicly accessible
NorthernSTAR Project Overcoat: Exterior Insulation Strategies for 1.5-Story Roof Applications in Cold Climates
This is a repository for all NorthernSTAR Overcoat insulation retrofit projects. Both houses received Overcoat insulation retrofit on roof only, performed by Cocoon Insulation.
1 St. Louis Park house St. Louis Park, MN
2 Edina house Edina, MN
In this second study, the team wishe...
Jacobson, R. et al University of Minnesota NorthernSTAR Building America Partnership
Apr 27, 2016
10 Resources
0 Stars
Publicly accessible
10 Resources
0 Stars
Publicly accessible
Evaluation of Early Performance Results for Massachusetts Homes in the National Grid Pilot Deep Energy Retrofit Program
In 2009, National Grid started a DER pilot program that offered technical support and financial incentives to qualified Massachusetts homeowners who planned and successfully completed a retrofit that incorporated the performance requirements and goals of the National Grid DER meas...
Neuhauser, K. and Gates, C. Building Science Corporation
Apr 27, 2016
29 Resources
0 Stars
Publicly accessible
29 Resources
0 Stars
Publicly accessible
Evaluation of the U.S. Department of Energy Challenge Home Program Certification of Production Builders Chicago, IL and Devens, MA
TO4 Task 3.1 K Hovnanian Chicago, IL
DOE Challenge Home Program Certified
Home Constructed and Verified
Specifications
DOE Challenge Home
Building envelope
Ceiling R-49 blown fiberglass, Grade I
Walls 2x4 framing @ 16 o.c. with R-13 fiberglass batts, Grade I
and 1"" R-5 extrude...
Loomis, H. and Kerrigan, P. Building Science Corporation
Apr 27, 2016
6 Resources
0 Stars
Publicly accessible
6 Resources
0 Stars
Publicly accessible
Analysis of Pre-Retrofit Building and Utility Data Southeast United States
TO4 9.1.2: Comm. Scale Military Housing Upgrades
This project delves into the workflow and results of regression models on monthly and daily utility data (meter readings of electricity consumption), outlining a process for screening and gathering useful results from inverse model...
Beach, R. and Prahl, D. Ibacos Innovation
Apr 27, 2016
12 Resources
0 Stars
In curation
12 Resources
0 Stars
In curation
Raleigh Housing Authority Duct Sealing Evaluation
In multifamily and attached buildings, manual duct sealing methods are often impractical or very costly and disruptive because of the difficulty in accessing leakage sites. In this project, two retrofit duct sealing techniques manually applied sealants and injecting a spray sealan...
Dentz, J. et al The Levy Partnership, Inc Systems Building Research Alliance
Apr 27, 2016
18 Resources
0 Stars
Publicly accessible
18 Resources
0 Stars
Publicly accessible
Field Testing of Compartmentalization Methods for Multifamily Construction Washington DC
BSC TO5 Task 2.1 Field Testing of Compartmentalization Methods for Multifamily Construction Capitol Heights, MD 20743
A building comprising five vertical townhome units was built in the Washington, D.C., area; the townhomes were three-story slab-on-grade units (1700-2000 ft2) wit...
Ueno, K. and Lstiburek, J. Building Science Corporation
Apr 27, 2016
22 Resources
0 Stars
Publicly accessible
22 Resources
0 Stars
Publicly accessible
Greenbuilt Construction Energy Efficiency Retrofit House Demonstration Sacramento
One of the homes that was part of Sacramento Municipal Utility District's (SMUD) Energy Efficiency Retrofit Demonstration (EERD) project was a 1980's era home in Fair Oaks, California, referred to as the Greenbuilt house, as Greenbuilt Construction completed the retrofit of the h...
Sparn, B. et al Mountain Energy Partnership
Aug 27, 2018
8 Resources
0 Stars
Publicly accessible
8 Resources
0 Stars
Publicly accessible
Commercial and Residential Hourly Load Profiles for all TMY3 Locations in the United States
Note: This dataset has been superseded by the dataset found at "End-Use Load Profiles for the U.S. Building Stock" (submission 4520; linked in the submission resources), which is a comprehensive and validated representation of hourly load profiles in the U.S. commercial and reside...
Ong, S. and Clark, N. National Renewable Energy Laboratory
Nov 25, 2014
22 Resources
0 Stars
Curated
22 Resources
0 Stars
Curated