Hathaway Solar Patriot house
This Dataset contains field research raw data, analysis spreadsheet, photos, and final report from the Hathaway Solar Patriot House Building America Case Study project.
Norton, P. National Renewable Energy Laboratory
Jun 09, 2016
6 Resources
0 Stars
In curation
6 Resources
0 Stars
In curation
Hathaway Solar Patriot House
The Hathaway Solar Patriot House was a Building America field research case study from 2001 to 2004. A report on this project is available in this record or from the National Renewable Energy Laboratory.
http://www.nrel.gov/docs/fy05osti/37731.pdf
Norton, P. and Laboratory, N. National Renewable Energy Laboratory
Jun 10, 2016
4 Resources
0 Stars
In curation
4 Resources
0 Stars
In curation
Modeled Performance of the Hathaway Solar Patriot house Washington D.C
This Dataset contains field research raw data, analysis spreadsheet, photos, and final report from the Hathaway Solar Patriot House Building America Case Study project.
This dataset details the monitored and modeled performance of a solar home outside of Washington, D.C. We model...
Norton, P. et al National Renewable Energy Laboratory
Jun 20, 2016
5 Resources
0 Stars
Publicly accessible
5 Resources
0 Stars
Publicly accessible
Performance and Costs of Ductless Heat Pumps in Marine-Climate High-Performance Homes Habitat for Humanity The Woods
The Washington State University (WSU) Energy Program's Building America (BA) team conducted a case study of a high-performance affordable housing community: The Woods (Figure 1). This BA effort is part of a larger-scale study of 30 homes funded from 2013-2016 by Tacoma Public Util...
Lubliner, M. et al Washington State University
Apr 27, 2016
8 Resources
0 Stars
Publicly accessible
8 Resources
0 Stars
Publicly accessible
Air Leakage and Air Transfer Between Garage and Living Space
This research project focused on evaluation of air transfer between the garage and living space in a single-family detached home constructed by a production homebuilder in compliance with the 2009 International Residential Code and the 2009 International Energy Conservation Code. ...
Rudd, A. and Kerrigan, P. Advanced Building Systems
Apr 27, 2016
2 Resources
0 Stars
Publicly accessible
2 Resources
0 Stars
Publicly accessible
Field Testing of an Unvented Roof with Fibrous Insulation, Tiles, and Vapor Diffusion Venting
BSC TO5 Task 2.5 Field Testing of an Un-vented Roof with Fibrous Insulation and Tiles Winter Park, FL 32789
Field test data available for wood moisture contents, temperature, and relative humidity.
Un-vented roofs (aka cathedral-ized attics) are an established presence in Florida...
Ueno, K. and Lstiburek, J. Building Science Corporation
Apr 27, 2016
2 Resources
0 Stars
Publicly accessible
2 Resources
0 Stars
Publicly accessible
Excavationless Exterior Foundation Insulation Field Study Minnesota
The NorthernSTAR Building America Partnership team implemented an innovative, minimally invasive foundation insulation upgrade technique on an existing home. The approach consisted of using hydrovac excavation technology combined with a liquid insulating foam. Two houses were orig...
Jacobson, R. et al University of Minnesota NorthernSTAR Building America Partnership
Apr 27, 2016
11 Resources
0 Stars
Publicly accessible
11 Resources
0 Stars
Publicly accessible
Field Testing Unvented Roofs with Asphalt Shingles in Cold and Hot-humid Climates
BSC TO5 Task 7.1 Field Testing Unvented Roofs with Asphalt Shingles in Cold Climates Bolingbrook, IL 60440
BSC TO5 Task 7.1 Field Testing Unvented Roofs with Asphalt Shingles in Hot-Humid Climates Friendswood, TX 77546
To understand the long-term moisture performance of unvented ...
Ueno, K. and Lstiburek, J. Building Science Corporation
Apr 27, 2016
3 Resources
0 Stars
Publicly accessible
3 Resources
0 Stars
Publicly accessible
Mass Customization of Prefabricated Panel Blocks for Deep Wall Insulation Retrofits
The project this data comes from looks to make building wall retrofits less expensive and easier to install by using exterior insulating panels. This is done to make buildings more energy efficient without expensive wall retrofits or reconstruction. The "Measurement and Verificati...
Sharon, A. et al Fraunhofer Center for Manufacturing Innovation CMI
Dec 14, 2021
2 Resources
0 Stars
Publicly accessible
2 Resources
0 Stars
Publicly accessible
Solar Row Zero Energy Townhomes Boulder, CO
Wonderland Development has constructed a new "near zero energy" row home design in North Boulder consisting of 9 units: one 5-plex and two duplexes. NREL has performed short-term tests and installed long-term monitoring equipment in three of these units. Two of these units used a ...
Norton, P. et al National Renewable Energy Laboratory
Sep 27, 2016
11 Resources
0 Stars
Publicly accessible
11 Resources
0 Stars
Publicly accessible
Moisture Risk in Unvented Attics Due to Air Leakage Paths Minneapolis Minnesota
IBACOS completed an initial analysis of moisture damage potential in an unvented attic insulated with closed-cell spray polyurethane foam. To complete this analysis, the research team collected field data, used computational fluid dynamics to quantify the airflow rates through ind...
Rapport, A. et al Ibacos Innovation
Apr 27, 2016
6 Resources
0 Stars
Publicly accessible
6 Resources
0 Stars
Publicly accessible
Spray Foam Exterior Insulation with Stand-Off Furring New York
IBACOS and Green Homes America 1 (GHA) collaborated with the New York State Energy Research and Development Authority (NYSERDA) Advanced Buildings Program to research a variation of a commercial curtain wall assembly for residential construction as part of a comprehensive whole-ho...
Rapport, A. et al Ibacos Innovation
Apr 27, 2016
2 Resources
0 Stars
Publicly accessible
2 Resources
0 Stars
Publicly accessible
Advancing Replicable Solutions for High-Performance Homes in the Southeast JMC Patrick Square
The work presented in this report advances the goals of the U.S. Department of Energy Building America program by improving the energy peformance of affordable and market-rate housing. Southface Energy Institute (Southface), part of the U.S. Department of Energy Building America r...
Sweet, M. et al Southface
Apr 27, 2016
3 Resources
0 Stars
Publicly accessible
3 Resources
0 Stars
Publicly accessible
Multifamily Programmable Thermostat Data
This data set, compiled by the Fraunhofer Center for Sustainable Energy Systems, includes long-term 10-minute temperature and relative humidity data, and HVAC system state data for 79 apartments in a low-income housing complex in Revere, MA. The monitoring period spans two winters...
Urban, B. et al Fraunhofer USA
Jul 27, 2015
2 Resources
0 Stars
Publicly accessible
2 Resources
0 Stars
Publicly accessible
Phased Retrofits in Existing Homes in Florida Phase I: Shallow and Deep Retrofits
The U.S. Department of Energy's Building America research team Building America Partnership for Improved Residential Construction is collaborating with Florida Power & Light (FPL) to conduct a phased residential energy-efficiency retrofit program. This research seeks to establish ...
Beal, D. et al University of Central Florida Florida Solar Energy Center
Apr 27, 2016
10 Resources
0 Stars
Publicly accessible
10 Resources
0 Stars
Publicly accessible
Evaluation of the Performance of Houses With and Without Supplemental Dehumidification in a Hot-Humid Climate
Understanding indoor humidity conditions in low energy homes in hot-humid climates is critical to promoting long term occupant comfort, indoor air quality and building durability. The results of this study were expected to inform the residential building community on whether suppl...
Kerrigan, P. and Norton, P. National Renewable Energy Laboratory
Apr 27, 2016
7 Resources
0 Stars
Publicly accessible
7 Resources
0 Stars
Publicly accessible
Commercial Reference Building: Midrise Apartment
Commercial reference buildings provide complete descriptions for whole building energy analysis using EnergyPlus (see "About EnergyPlus" resource link) simulation software. Included here is data pertaining to the reference building type "Midrise Apartment" for each of the 16 clima...
Deru, M. et al National Renewable Energy Laboratory
Nov 25, 2014
7 Resources
0 Stars
In curation
7 Resources
0 Stars
In curation
Commercial Reference Building: Primary School
Commercial reference buildings provide complete descriptions for whole building energy analysis using EnergyPlus (see "About EnergyPlus" resource link) simulation software. Included here is data pertaining to the reference building type "Primary School" for each of the 16 climate ...
Deru, M. et al National Renewable Energy Laboratory
Nov 25, 2014
7 Resources
0 Stars
In curation
7 Resources
0 Stars
In curation
Commercial Reference Building: Quick Service Restaurant
Commercial reference buildings provide complete descriptions for whole building energy analysis using EnergyPlus (see "About EnergyPlus" resource link) simulation software. Included here is data pertaining to the reference building type "Quick Service Restaurant" for each of the 1...
Deru, M. et al National Renewable Energy Laboratory
Nov 25, 2014
7 Resources
0 Stars
In curation
7 Resources
0 Stars
In curation
Commercial Reference Building: Secondary School
Commercial reference buildings provide complete descriptions for whole building energy analysis using EnergyPlus (see "About EnergyPlus" resource link) simulation software. Included here is data pertaining to the reference building type "Secondary School" for each of the 16 climat...
Deru, M. et al National Renewable Energy Laboratory
Nov 25, 2014
7 Resources
0 Stars
In curation
7 Resources
0 Stars
In curation
Commercial Reference Building: Small Hotel
Commercial reference buildings provide complete descriptions for whole building energy analysis using EnergyPlus (see "About EnergyPlus" resource link) simulation software. Included here is data pertaining to the reference building type "Small Hotel" for each of the 16 climate zon...
Deru, M. et al National Renewable Energy Laboratory
Nov 25, 2014
7 Resources
0 Stars
In curation
7 Resources
0 Stars
In curation
Commercial Reference Building: Small Office
Commercial reference buildings provide complete descriptions for whole building energy analysis using EnergyPlus (see "About EnergyPlus" resource link) simulation software. Included here is data pertaining to the reference building type "Small Office" for each of the 16 climate zo...
Deru, M. et al National Renewable Energy Laboratory
Nov 25, 2014
7 Resources
0 Stars
In curation
7 Resources
0 Stars
In curation
Commercial Reference Building: Strip Mall
Commercial reference buildings provide complete descriptions for whole building energy analysis using EnergyPlus (see "About EnergyPlus" resource link) simulation software. Included here is data pertaining to the reference building type "Strip Mall" for each of the 16 climate zone...
Deru, M. et al National Renewable Energy Laboratory
Nov 25, 2014
7 Resources
0 Stars
In curation
7 Resources
0 Stars
In curation
Commercial Reference Building: Supermarket
Commercial reference buildings provide complete descriptions for whole building energy analysis using EnergyPlus (see "About EnergyPlus" resource link) simulation software. Included here is data pertaining to the reference building type "Supermarket" for each of the 16 climate zon...
Deru, M. et al National Renewable Energy Laboratory
Nov 25, 2014
7 Resources
0 Stars
In curation
7 Resources
0 Stars
In curation
Commercial Reference Building: Warehouse
Commercial reference buildings provide complete descriptions for whole building energy analysis using EnergyPlus (see "About EnergyPlus" resource link) simulation software. Included here is data pertaining to the reference building type "Warehouse" for each of the 16 climate zones...
Deru, M. et al National Renewable Energy Laboratory
Nov 25, 2014
7 Resources
0 Stars
In curation
7 Resources
0 Stars
In curation