Evaluating an Exterior Insulation and Finish System for Deep Energy Retrofits

This report provides a case study of a deep energy retrofit using a site-applied exterior insulation and finish system (EIFS). Prefabricated EIFS panels are also discussed as a potential wall insulation retrofit solution. EIFSs are common in new and retrofit commercial constructio...
Dentz, J. and Podorson, D. The Levy Partnership, Inc Systems Building Research Alliance
Apr 27, 2016
2 Resources
0 Stars
Publicly accessible

DOE Challenge Home Multifamily Development Mixed Climate

The U.S. Department of Energys Zero Energy Ready Home (ZERH) recognition program builds upon the building science requirements of ENERGY STAR Certified Homes, Version 3 and best practices tested by the Building America research and demonstration program. Multifamily units (units i...
Dentz, J. and Alaigh, K. The Levy Partnership, Inc Systems Building Research Alliance
Apr 27, 2016
5 Resources
0 Stars
Publicly accessible

TP84227_FS83049_OPData

The data set represents the data used for the analysis of operational carbon emissions for a carbon case study of a typical production builder's home in two common climate zones, Climate Zone 2 (Warm) and CZ 5 (Cold). A data set for embodied carbon emissions analysis for the sam...
RapportBuilding Technologies and Science Center
Jan 17, 2023
1 Resources
0 Stars
Publicly accessible

TP84227_FS83049_ECData

The data set represents the data used for the analysis of embodied carbon emissions for a carbon case study of a typical production builder's home in two common climate zones, Climate Zone 2 (Warm) and CZ 5 (Cold). A data set for operational carbon emissions analysis for the same...
RapportBuilding Technologies and Science Center
Jan 17, 2023
1 Resources
0 Stars
Publicly accessible

Moisture Risk in Unvented Attics Due to Air Leakage Paths Minneapolis Minnesota

IBACOS completed an initial analysis of moisture damage potential in an unvented attic insulated with closed-cell spray polyurethane foam. To complete this analysis, the research team collected field data, used computational fluid dynamics to quantify the airflow rates through ind...
Rapport, A. et al Ibacos Innovation
Apr 27, 2016
6 Resources
0 Stars
Publicly accessible

Long-run Marginal CO2 Emission Rates Workbooks for 2020 Standard Scenarios Cambium Data

This dataset has been superseded by a new set of workbooks that can be found here: https://data.nrel.gov/submissions/183 These workbooks contain modeled estimates of long-run marginal CO2 emission rates (LRMER) for the contiguous United States. The LRMER is an estimate of the...
Gagnon. . et al National Renewable Energy Laboratory
Aug 12, 2021
12 Resources
0 Stars
Publicly accessible

Monitoring of Double-Stud Wall Moisture Conditions in the Northeast

BSC TO5 Task 2.2 Monitoring of Double Stud Wall Moisture Conditions in the Northeast Field test data available for wood moisture contents, temperature, and relative humidity. STRUCTURE House Devens, MA 01432 Three double-stud assemblies were compared: 12-in. ocSPF, 12-in. cellulo...
Ueno, K. Building Science Corporation
Apr 27, 2016
2 Resources
0 Stars
Publicly accessible

Field Testing of an Unvented Roof with Fibrous Insulation, Tiles, and Vapor Diffusion Venting

BSC TO5 Task 2.5 Field Testing of an Un-vented Roof with Fibrous Insulation and Tiles Winter Park, FL 32789 Field test data available for wood moisture contents, temperature, and relative humidity. Un-vented roofs (aka cathedral-ized attics) are an established presence in Florida...
Ueno, K. and Lstiburek, J. Building Science Corporation
Apr 27, 2016
2 Resources
0 Stars
Publicly accessible

Long-Run Marginal Emission Rates for Electricity Workbooks for 2021 Cambium Data

These workbooks contain modeled estimates of long-run marginal emission rates (LRMER) for the contiguous United States. The LRMER is an estimate of the rate of emissions that would be either induced or avoided by a long-term (i.e., more than several years) change in electrical dem...
Gagnon. . et al National Renewable Energy Laboratory
Jan 05, 2022
4 Resources
0 Stars
Publicly accessible

Big Box Retail Grocery Store and Electric Vehicle Station Load Profiles

This dataset includes yearlong, one-minute resolution time series profiles for the big box retail grocery stores stores simulated in Phoenix, Houston, Denver, and Minneapolis, as well as electric vehicle charging time series profiles for the various ports, charging levels, and sta...
Gilleran. . et al National Renewable Energy Laboratory
Oct 22, 2021
3 Resources
0 Stars
Publicly accessible

Measure Guideline: Deep Energy Enclosure Retrofit for Interior Insulation of Masonry Walls and Flat Roofs

Measure Guideline: Deep Energy Enclosure Retrofit for Zero Energy Ready House Flat Roofs BSC TO5 Task 7.4 Deep Energy Enclosure Retrofit (DEER) for Interior Insulation of Masonry Walls Lawrence, MA 01840 This Measure Guideline describes a deep energy enclosure retrofit solution ...
Musunuru, S. et al Building Science Corporation
Apr 27, 2016
5 Resources
0 Stars
Publicly accessible

LBNL Fault Detection and Diagnostics Datasets

These datasets can be used to evaluate and benchmark the performance accuracy of Fault Detection and Diagnostics (FDD) algorithms or tools. It contains operational data from simulation, laboratory experiments, and field measurements from real buildings for seven HVAC systems/equip...
Granderson, J. et al Lawrence Berkeley National Laboratory
Aug 01, 2022
5 Resources
0 Stars
Publicly accessible

Thermostatic Radiator Valve Evaluation and Demonstration

A large stock of multifamily buildings in the Northeast and Midwest uses hot water or steam for space heating. Typically, residents do not pay for heat directly (i.e., heating fuel serves a central plant and use is not submetered). Losses from these systems are typically high, and...
Dentz, J. and Ansanelli, E. The Levy Partnership, Inc Systems Building Research Alliance
Apr 27, 2016
2 Resources
0 Stars
Publicly accessible

Advancing Replicable Solutions for High-Performance Homes in the Southeast JMC Patrick Square

The work presented in this report advances the goals of the U.S. Department of Energy Building America program by improving the energy peformance of affordable and market-rate housing. Southface Energy Institute (Southface), part of the U.S. Department of Energy Building America r...
Sweet, M. et al Southface
Apr 27, 2016
3 Resources
0 Stars
Publicly accessible

NorthernSTAR Project Overcoat: Exterior Insulation Strategies for 1.5-Story Roof Applications in Cold Climates

This is a repository for all NorthernSTAR Overcoat insulation retrofit projects. Both houses received Overcoat insulation retrofit on roof only, performed by Cocoon Insulation. 1 St. Louis Park house St. Louis Park, MN 2 Edina house Edina, MN In this second study, the team wishe...
Jacobson, R. et al University of Minnesota NorthernSTAR Building America Partnership
Apr 27, 2016
10 Resources
0 Stars
Publicly accessible

Evaluation of Early Performance Results for Massachusetts Homes in the National Grid Pilot Deep Energy Retrofit Program

In 2009, National Grid started a DER pilot program that offered technical support and financial incentives to qualified Massachusetts homeowners who planned and successfully completed a retrofit that incorporated the performance requirements and goals of the National Grid DER meas...
Neuhauser, K. and Gates, C. Building Science Corporation
Apr 27, 2016
29 Resources
0 Stars
Publicly accessible

Analysis of Joist Masonry Moisture Content Monitoring

BSC TO5 Task 7.2 Analysis of Joist Masonry Moisture Content Monitoring House Lawrence, MA 01840 This work involved the field monitoring of embedded wood joist ends in a solid brick building in zone 5A that was retrofitted with interior insulation. Eleven joists throughout the bui...
Ueno, K. Building Science Corporation
Apr 27, 2016
3 Resources
0 Stars
Publicly accessible

Performance and Costs of Ductless Heat Pumps in Marine-Climate High-Performance Homes Habitat for Humanity The Woods

The Washington State University (WSU) Energy Program's Building America (BA) team conducted a case study of a high-performance affordable housing community: The Woods (Figure 1). This BA effort is part of a larger-scale study of 30 homes funded from 2013-2016 by Tacoma Public Util...
Lubliner, M. et al Washington State University
Apr 27, 2016
8 Resources
0 Stars
Publicly accessible

Evaluation of Crawlspace Retrofits in Multifamily Buildings

In 2011 and early 2012, Building Science Corporation (BSC) collaborated with Innova Services Corporation on a multifamily community un-vented crawlspace retrofit project at Oakwood Gardens in Lansdale, Pennsylvania. BSC provided design consulting services and pre and post-retrofit...
Rudd, A. Advanced Building Systems
Apr 27, 2016
41 Resources
0 Stars
Publicly accessible
  • About the Open Energy Data Initiative
  • Partners & Sponsors
  • Disclaimers
  • Developer Services
  • The OEDI Data Lake is a centralized repository of datasets aggregated from the U.S. Department of Energy’s Programs, Offices, and National Laboratories.
  • Content is available under Creative Commons Attribution 4.0 unless otherwise noted.

Privacy Policy Notification

This site uses cookies to store and share user preferences with other OpenEI sites, and uses Google Analytics to collect anonymous user information such as which pages are visited, for how often, and what searches or other webpages may have led users here. You can prevent Google Analytics from recognizing you on return visits to this site by disabling cookies on your browser or by installing a Google Analytics Opt-out Browser Add-on. By clicking "Accept" you agree this site can store cookies on your device and disclose information to OpenEI and Google Analytics in accordance with our privacy policy.

OpenEI Privacy Policy Google Analytics Terms of Service