Analysis of Joist Masonry Moisture Content Monitoring
BSC TO5 Task 7.2 Analysis of Joist Masonry Moisture Content Monitoring
House Lawrence, MA 01840
This work involved the field monitoring of embedded wood joist ends in a solid brick building in zone 5A that was retrofitted with interior insulation. Eleven joists throughout the bui...
Ueno, K. Building Science Corporation
Apr 27, 2016
3 Resources
0 Stars
Publicly accessible
3 Resources
0 Stars
Publicly accessible
Monitoring of Double-Stud Wall Moisture Conditions in the Northeast
BSC TO5 Task 2.2 Monitoring of Double Stud Wall Moisture Conditions in the Northeast
Field test data available for wood moisture contents, temperature, and relative humidity.
STRUCTURE House Devens, MA 01432
Three double-stud assemblies were compared: 12-in. ocSPF, 12-in. cellulo...
Ueno, K. Building Science Corporation
Apr 27, 2016
2 Resources
0 Stars
Publicly accessible
2 Resources
0 Stars
Publicly accessible
Performance and Costs of Ductless Heat Pumps in Marine-Climate High-Performance Homes Habitat for Humanity The Woods
The Washington State University (WSU) Energy Program's Building America (BA) team conducted a case study of a high-performance affordable housing community: The Woods (Figure 1). This BA effort is part of a larger-scale study of 30 homes funded from 2013-2016 by Tacoma Public Util...
Lubliner, M. et al Washington State University
Apr 27, 2016
8 Resources
0 Stars
Publicly accessible
8 Resources
0 Stars
Publicly accessible
Solar Row Zero Energy Townhomes Boulder, CO
Wonderland Development has constructed a new "near zero energy" row home design in North Boulder consisting of 9 units: one 5-plex and two duplexes. NREL has performed short-term tests and installed long-term monitoring equipment in three of these units. Two of these units used a ...
Norton, P. et al National Renewable Energy Laboratory
Sep 27, 2016
11 Resources
0 Stars
Publicly accessible
11 Resources
0 Stars
Publicly accessible
Evaluation of the Performance of Houses With and Without Supplemental Dehumidification in a Hot-Humid Climate
Understanding indoor humidity conditions in low energy homes in hot-humid climates is critical to promoting long term occupant comfort, indoor air quality and building durability. The results of this study were expected to inform the residential building community on whether suppl...
Kerrigan, P. and Norton, P. National Renewable Energy Laboratory
Apr 27, 2016
7 Resources
0 Stars
Publicly accessible
7 Resources
0 Stars
Publicly accessible
Demand-Side Grid (dsgrid) Highly-resolved, Long-term Energy Demand Projections for the Contiguous United States: DECARB Scenarios
Input and compiled datasets describing projected energy use by sector and for the power sector as a whole. Data are developed by a multi-national lab team as part of the U.S. Department of Energy (DOE) Energy Efficiency and Renewable Energy (EERE) Office's DECARB project.
Hale, E. et al National Renewable Energy Laboratory
Jul 01, 2024
2 Resources
0 Stars
In progress
2 Resources
0 Stars
In progress
Oak Ridge National Laboratory NILMS Project FRP #2
DOE funded research for NILMS and Fault Detection for small and medium commercial buildings. This contains notes, documentation, and data from Flexible Research Platform #2. This data can be used to study Non-intrusive Load Monitoring approaches.
The data is 30 second sample p...
Fugate, D. and Laboratory, O. Oak Ridge National Laboratory
Mar 20, 2017
4 Resources
0 Stars
In curation
4 Resources
0 Stars
In curation
Oak Ridge National Laboratory NILMS Project FRP No #1
DOE funded research for NILMS and Fault Detection for small and medium commercial buildings. This contains notes, documentation, and data from Flexible Research Platform #1. This data can be used to study Non-intrusive Load Monitoring approaches.
The data is 30 second sample po...
Fugate, D. and Laboratory, O. Oak Ridge National Laboratory
Mar 20, 2017
4 Resources
0 Stars
In curation
4 Resources
0 Stars
In curation
Evaluation of Early Performance Results for Massachusetts Homes in the National Grid Pilot Deep Energy Retrofit Program
In 2009, National Grid started a DER pilot program that offered technical support and financial incentives to qualified Massachusetts homeowners who planned and successfully completed a retrofit that incorporated the performance requirements and goals of the National Grid DER meas...
Neuhauser, K. and Gates, C. Building Science Corporation
Apr 27, 2016
29 Resources
0 Stars
Publicly accessible
29 Resources
0 Stars
Publicly accessible
Evaluating an Exterior Insulation and Finish System for Deep Energy Retrofits
This report provides a case study of a deep energy retrofit using a site-applied exterior insulation and finish system (EIFS). Prefabricated EIFS panels are also discussed as a potential wall insulation retrofit solution. EIFSs are common in new and retrofit commercial constructio...
Dentz, J. and Podorson, D. The Levy Partnership, Inc Systems Building Research Alliance
Apr 27, 2016
2 Resources
0 Stars
Publicly accessible
2 Resources
0 Stars
Publicly accessible
New York State Energy Research and Development Authority Exterior Building Solutions To Insulation
TO4 8.2.2: Space Cond. for Deep Energy Retrofits
The purpose of this project for the New York State Energy Research and Development Authority (NYSERDA) is to find new or improved strategies for exterior building solutions in regard to insulation that will provide extensive energy...
Beach, R. et al Ibacos Innovation
Apr 27, 2016
14 Resources
0 Stars
Curated
14 Resources
0 Stars
Curated
Evaluation of the U.S. Department of Energy Challenge Home Program Certification of Production Builders Chicago, IL and Devens, MA
TO4 Task 3.1 K Hovnanian Chicago, IL
DOE Challenge Home Program Certified
Home Constructed and Verified
Specifications
DOE Challenge Home
Building envelope
Ceiling R-49 blown fiberglass, Grade I
Walls 2x4 framing @ 16 o.c. with R-13 fiberglass batts, Grade I
and 1"" R-5 extrude...
Loomis, H. and Kerrigan, P. Building Science Corporation
Apr 27, 2016
6 Resources
0 Stars
Publicly accessible
6 Resources
0 Stars
Publicly accessible
Irradiation Data from NREL'S MDIC Stations
The Measurement and Instrumentation Data Center (MIDC) provides Irradiance and Meteorological Data from these stations: NREL Solar Radiation Research Lab, BSRN Prototype Station, Atmospheric Optical Calibration System, TSR-1, RSR Version 2, RSR Version 1, National Wind Technology...
Afshin, A. and Laboratory, N. National Renewable Energy Laboratory
Nov 25, 2014
1 Resources
0 Stars
In curation
1 Resources
0 Stars
In curation
Sacramento Deep Energy Retrofit (DER) Home Study
This project was part of the Sacramento Municipal Utility District (SMUD) Deep Energy Retrofit (DER) Project which included several other homes in addition to the the subject of this study. Some of the reports and presentations included in this dataset cover the whole DER project....
Keesee, M. Sacramento Municipal Utility District
Aug 10, 2016
8 Resources
0 Stars
Publicly accessible
8 Resources
0 Stars
Publicly accessible
NorthernSTAR Project Overcoat: Exterior Insulation Strategies for 1.5-Story Roof Applications in Cold Climates
This is a repository for all NorthernSTAR Overcoat insulation retrofit projects. Both houses received Overcoat insulation retrofit on roof only, performed by Cocoon Insulation.
1 St. Louis Park house St. Louis Park, MN
2 Edina house Edina, MN
In this second study, the team wishe...
Jacobson, R. et al University of Minnesota NorthernSTAR Building America Partnership
Apr 27, 2016
10 Resources
0 Stars
Publicly accessible
10 Resources
0 Stars
Publicly accessible
Federal Greenhouse Gas Inventories and Performance
The Federal Energy Management Program (FEMP) provides progress data tables illustrating Federal agency progress in meeting the greenhouse gas (GHG) reduction targets established under Executive Order (E.O.) 13514, as well as the comprehensive greenhouse gas inventories as reported...
Tremper, C. and (EERE), O. Office of Energy Efficiency & Renewable Energy
Nov 25, 2014
1 Resources
0 Stars
In curation
1 Resources
0 Stars
In curation
Conway St Apartments Olive Street Development
In Greenfield, Massachusetts, Olive Street Development transformed an old elementary school building into 12 high-end rental apartments. The developer aimed to get as close to net-zero performance as practical, installing: (1) R-30 high-density spray foam against the brick walls (...
Aldrich, R. and Williamson, J. Steven Winter Associates of the Consortium for Advanced Residential Buildings
Apr 27, 2016
2 Resources
0 Stars
In curation
2 Resources
0 Stars
In curation
Spray Foam Exterior Insulation with Stand-Off Furring New York
IBACOS and Green Homes America 1 (GHA) collaborated with the New York State Energy Research and Development Authority (NYSERDA) Advanced Buildings Program to research a variation of a commercial curtain wall assembly for residential construction as part of a comprehensive whole-ho...
Rapport, A. et al Ibacos Innovation
Apr 27, 2016
2 Resources
0 Stars
Publicly accessible
2 Resources
0 Stars
Publicly accessible
Data of PV panel attached on building
To use these files, please read the "Readme" file and the following items:
There are seven files, six of which are ".xlsx" and the last one is ".m".
1. Code_building_2: This file contains the code base for data analysis, making and plotting mathematical models using Mathlab softwa...
Alvarez, L. University of Illinois
Oct 12, 2020
8 Resources
0 Stars
In progress
8 Resources
0 Stars
In progress
Technology Performance Exchange
The Technology Performance Exchange (TPEx) is a centralized, Web-based portal for finding and sharing energy performance data for commercial building technologies. Individuals who manufacture, supply, test, or evaluate technologies can use data entry forms to upload standardized, ...
Unruh, T. and (EERE), O. Office of Energy Efficiency & Renewable Energy
Nov 25, 2014
2 Resources
0 Stars
In curation
2 Resources
0 Stars
In curation
Innovative Technologies to Overcome Interface Challenges for Wall Retrofit Systems
In this project, we will develop a system of computer-assisted, automated workflows to specify, manufacture, and install panelized retrofit systems, focusing particularly on panel joints and interface detailing between the panels and facade openings. The proposed system will subst...
Harris, C. et al National Renewable Energy Laboratory (NREL)
Dec 13, 2021
3 Resources
0 Stars
Publicly accessible
3 Resources
0 Stars
Publicly accessible
State Energy Efficient Appliance Rebate Program (SEEARP) Reports
The State Energy Efficient Appliance Rebate Program (SEEARP) reports database includes rebate reports (xls) and summary factsheets (pdf) from states and territories that participated in SEEARP. With funding provided by the American Recovery and Reinvestment Act of 2009 (ARRA), the...
Hoffmeyer, D. Office of Energy Efficiency and Renewable Energy
Jun 18, 2015
5 Resources
0 Stars
Publicly accessible
5 Resources
0 Stars
Publicly accessible
Air Leakage and Air Transfer Between Garage and Living Space
This research project focused on evaluation of air transfer between the garage and living space in a single-family detached home constructed by a production homebuilder in compliance with the 2009 International Residential Code and the 2009 International Energy Conservation Code. ...
Rudd, A. and Kerrigan, P. Advanced Building Systems
Apr 27, 2016
2 Resources
0 Stars
Publicly accessible
2 Resources
0 Stars
Publicly accessible
Moisture Risk in Unvented Attics Due to Air Leakage Paths Minneapolis Minnesota
IBACOS completed an initial analysis of moisture damage potential in an unvented attic insulated with closed-cell spray polyurethane foam. To complete this analysis, the research team collected field data, used computational fluid dynamics to quantify the airflow rates through ind...
Rapport, A. et al Ibacos Innovation
Apr 27, 2016
6 Resources
0 Stars
Publicly accessible
6 Resources
0 Stars
Publicly accessible
Raleigh Housing Authority Duct Sealing Evaluation
In multifamily and attached buildings, manual duct sealing methods are often impractical or very costly and disruptive because of the difficulty in accessing leakage sites. In this project, two retrofit duct sealing techniques manually applied sealants and injecting a spray sealan...
Dentz, J. et al The Levy Partnership, Inc Systems Building Research Alliance
Apr 27, 2016
18 Resources
0 Stars
Publicly accessible
18 Resources
0 Stars
Publicly accessible