Search OEDI Data
Showing results 1 - 18 of 18.
Show
results per page.
Order by:
Available Now:
Research Areas
Accessibility
Data Type
Organization
Source
Air Leakage and Air Transfer Between Garage and Living Space
This research project focused on evaluation of air transfer between the garage and living space in a single-family detached home constructed by a production homebuilder in compliance with the 2009 International Residential Code and the 2009 International Energy Conservation Code. ...
Rudd, A. and Kerrigan, P. Advanced Building Systems
Apr 27, 2016
2 Resources
0 Stars
Publicly accessible
2 Resources
0 Stars
Publicly accessible
Mechanical Ventilation and Indoor Air Quality in Recently Constructed U.S. Homes in Marine and Cold-Dry Climates Data from Building America Project
Data were collected to characterize whole-house mechanical ventilation (WHMV) and indoor air quality (IAQ) in 55 homes in the Marine climate of Oregon and Cold-Dry climate of Colorado in the U.S. Sixteen homes were monitored for two weeks, with and without WHMV operating. Ventilat...
Zhao, H. et al Lawrence Berkeley National Laboratory
Mar 22, 2023
2 Resources
0 Stars
Publicly accessible
2 Resources
0 Stars
Publicly accessible
Evaluation of the U.S. Department of Energy Challenge Home Program Certification of Production Builders Chicago, IL and Devens, MA
TO4 Task 3.1 K Hovnanian Chicago, IL
DOE Challenge Home Program Certified
Home Constructed and Verified
Specifications
DOE Challenge Home
Building envelope
Ceiling R-49 blown fiberglass, Grade I
Walls 2x4 framing @ 16 o.c. with R-13 fiberglass batts, Grade I
and 1"" R-5 extrude...
Loomis, H. and Kerrigan, P. Building Science Corporation
Apr 27, 2016
6 Resources
0 Stars
Publicly accessible
6 Resources
0 Stars
Publicly accessible
Monitoring of Double-Stud Wall Moisture Conditions in the Northeast
BSC TO5 Task 2.2 Monitoring of Double Stud Wall Moisture Conditions in the Northeast
Field test data available for wood moisture contents, temperature, and relative humidity.
STRUCTURE House Devens, MA 01432
Three double-stud assemblies were compared: 12-in. ocSPF, 12-in. cellulo...
Ueno, K. Building Science Corporation
Apr 27, 2016
2 Resources
0 Stars
Publicly accessible
2 Resources
0 Stars
Publicly accessible
Brookfield Homes Passive House Performance Evaluation
TO4 3.1.3: Brookfield Homes Short-Term Results
TO5 3.1.3: Brookfield Passive House Monitoring
To further define its market position on high performance homebuilding, Brookfield worked with IBACOS and the Building America program to design and construct a Passive House (PH) certif...
Beach, R. et al Ibacos Innovation
Apr 27, 2016
4 Resources
0 Stars
Publicly accessible
4 Resources
0 Stars
Publicly accessible
Simplified Space Conditioning in Low-Load Homes
TO3 2.1.6: Simplified Space Conditioning
IBACOS anticipates that houses achieving 50% whole-house source energy savings with respect to the Building America 2010 Benchmark (Hendron and Engebrecht 2010a) will be considered "low load." Low load is defined by IBACOS as a house with ...
Poerschke, A. and Stecher, D. Ibacos Innovation
Apr 27, 2016
2 Resources
0 Stars
Publicly accessible
2 Resources
0 Stars
Publicly accessible
Hathaway Solar Patriot House
The Hathaway Solar Patriot House was a Building America field research case study from 2001 to 2004. A report on this project is available in this record or from the National Renewable Energy Laboratory.
http://www.nrel.gov/docs/fy05osti/37731.pdf
Norton, P. and Laboratory, N. National Renewable Energy Laboratory
Jun 10, 2016
4 Resources
0 Stars
In curation
4 Resources
0 Stars
In curation
Performance and Costs of Ductless Heat Pumps in Marine-Climate High-Performance Homes Habitat for Humanity The Woods
The Washington State University (WSU) Energy Program's Building America (BA) team conducted a case study of a high-performance affordable housing community: The Woods (Figure 1). This BA effort is part of a larger-scale study of 30 homes funded from 2013-2016 by Tacoma Public Util...
Lubliner, M. et al Washington State University
Apr 27, 2016
8 Resources
0 Stars
Publicly accessible
8 Resources
0 Stars
Publicly accessible
Moisture Risk in Unvented Attics Due to Air Leakage Paths Minneapolis Minnesota
IBACOS completed an initial analysis of moisture damage potential in an unvented attic insulated with closed-cell spray polyurethane foam. To complete this analysis, the research team collected field data, used computational fluid dynamics to quantify the airflow rates through ind...
Rapport, A. et al Ibacos Innovation
Apr 27, 2016
6 Resources
0 Stars
Publicly accessible
6 Resources
0 Stars
Publicly accessible
Advancing Replicable Solutions for High-Performance Homes in the Southeast JMC Patrick Square
The work presented in this report advances the goals of the U.S. Department of Energy Building America program by improving the energy peformance of affordable and market-rate housing. Southface Energy Institute (Southface), part of the U.S. Department of Energy Building America r...
Sweet, M. et al Southface
Apr 27, 2016
3 Resources
0 Stars
Publicly accessible
3 Resources
0 Stars
Publicly accessible
Field Testing Unvented Roofs with Asphalt Shingles in Cold and Hot-humid Climates
BSC TO5 Task 7.1 Field Testing Unvented Roofs with Asphalt Shingles in Cold Climates Bolingbrook, IL 60440
BSC TO5 Task 7.1 Field Testing Unvented Roofs with Asphalt Shingles in Hot-Humid Climates Friendswood, TX 77546
To understand the long-term moisture performance of unvented ...
Ueno, K. and Lstiburek, J. Building Science Corporation
Apr 27, 2016
3 Resources
0 Stars
Publicly accessible
3 Resources
0 Stars
Publicly accessible
New York State Energy Research and Development Authority Exterior Building Solutions To Insulation
TO4 8.2.2: Space Cond. for Deep Energy Retrofits
The purpose of this project for the New York State Energy Research and Development Authority (NYSERDA) is to find new or improved strategies for exterior building solutions in regard to insulation that will provide extensive energy...
Beach, R. et al Ibacos Innovation
Apr 27, 2016
14 Resources
0 Stars
Curated
14 Resources
0 Stars
Curated
Approaches to 30% Energy Savings at the Community Scale in the Hot-Humid Climate
The Building America Partnership for Improved Residential Construction, formerly the Building America Industrialized Housing Partnership, has worked with several community-scale builders within the hot-humid climate zone to improve performance of production-, or community-scale, h...
Beal, D. et al University of Central Florida Florida Solar Energy Center
Apr 27, 2016
9 Resources
0 Stars
Publicly accessible
9 Resources
0 Stars
Publicly accessible
Modeled Performance of the Hathaway Solar Patriot house Washington D.C
This Dataset contains field research raw data, analysis spreadsheet, photos, and final report from the Hathaway Solar Patriot House Building America Case Study project.
This dataset details the monitored and modeled performance of a solar home outside of Washington, D.C. We model...
Norton, P. et al National Renewable Energy Laboratory
Jun 20, 2016
5 Resources
0 Stars
Publicly accessible
5 Resources
0 Stars
Publicly accessible
Field Testing of Compartmentalization Methods for Multifamily Construction Washington DC
BSC TO5 Task 2.1 Field Testing of Compartmentalization Methods for Multifamily Construction Capitol Heights, MD 20743
A building comprising five vertical townhome units was built in the Washington, D.C., area; the townhomes were three-story slab-on-grade units (1700-2000 ft2) wit...
Ueno, K. and Lstiburek, J. Building Science Corporation
Apr 27, 2016
22 Resources
0 Stars
Publicly accessible
22 Resources
0 Stars
Publicly accessible
Evaluating an Exterior Insulation and Finish System for Deep Energy Retrofits
This report provides a case study of a deep energy retrofit using a site-applied exterior insulation and finish system (EIFS). Prefabricated EIFS panels are also discussed as a potential wall insulation retrofit solution. EIFSs are common in new and retrofit commercial constructio...
Dentz, J. and Podorson, D. The Levy Partnership, Inc Systems Building Research Alliance
Apr 27, 2016
2 Resources
0 Stars
Publicly accessible
2 Resources
0 Stars
Publicly accessible
Thermostatic Radiator Valve Evaluation and Demonstration
A large stock of multifamily buildings in the Northeast and Midwest uses hot water or steam for space heating. Typically, residents do not pay for heat directly (i.e., heating fuel serves a central plant and use is not submetered). Losses from these systems are typically high, and...
Dentz, J. and Ansanelli, E. The Levy Partnership, Inc Systems Building Research Alliance
Apr 27, 2016
2 Resources
0 Stars
Publicly accessible
2 Resources
0 Stars
Publicly accessible
Greenbuilt Construction Energy Efficiency Retrofit House Demonstration Sacramento
One of the homes that was part of Sacramento Municipal Utility District's (SMUD) Energy Efficiency Retrofit Demonstration (EERD) project was a 1980's era home in Fair Oaks, California, referred to as the Greenbuilt house, as Greenbuilt Construction completed the retrofit of the h...
Sparn, B. et al Mountain Energy Partnership
Aug 27, 2018
8 Resources
0 Stars
Publicly accessible
8 Resources
0 Stars
Publicly accessible