Search OEDI Data
Showing results 26 - 50 of 223.
Show
results per page.
Order by:
Available Now:
Research Areas
Accessibility
Data Type
Organization
Source
TP84227_FS83049_ECData
The data set represents the data used for the analysis of embodied carbon emissions for a carbon case study of a typical production builder's home in two common climate zones, Climate Zone 2 (Warm) and CZ 5 (Cold). A data set for operational carbon emissions analysis for the same...
RapportBuilding Technologies and Science Center
Jan 17, 2023
1 Resources
0 Stars
Publicly accessible
1 Resources
0 Stars
Publicly accessible
NorthernStar Zero Energy Ready Homes
This is a repository for all NorthernSTAR Zero Energy Ready certified homes.
Amaris Homes Model Home St. Paul, MN 55110
Description: Model home completed September 2013
The DOE Zero Energy Ready Home Case Study looks to study and eventually design zero net energy homes in cold we...
Huelman, P. University of Minnesota NorthernSTAR Building America Partnership
Apr 27, 2016
20 Resources
0 Stars
Publicly accessible
20 Resources
0 Stars
Publicly accessible
Measure Guideline: Deep Energy Enclosure Retrofit for Interior Insulation of Masonry Walls and Flat Roofs
Measure Guideline: Deep Energy Enclosure Retrofit for Zero Energy Ready House Flat Roofs
BSC TO5 Task 7.4 Deep Energy Enclosure Retrofit (DEER) for Interior Insulation of Masonry Walls
Lawrence, MA 01840
This Measure Guideline describes a deep energy enclosure retrofit solution ...
Musunuru, S. et al Building Science Corporation
Apr 27, 2016
5 Resources
0 Stars
Publicly accessible
5 Resources
0 Stars
Publicly accessible
Thermostatic Radiator Valve Evaluation and Demonstration
A large stock of multifamily buildings in the Northeast and Midwest uses hot water or steam for space heating. Typically, residents do not pay for heat directly (i.e., heating fuel serves a central plant and use is not submetered). Losses from these systems are typically high, and...
Dentz, J. and Ansanelli, E. The Levy Partnership, Inc Systems Building Research Alliance
Apr 27, 2016
2 Resources
0 Stars
Publicly accessible
2 Resources
0 Stars
Publicly accessible
Measured Performance of a Varied Airflow Small-Diameter Duct System
In this study, researchers with the U.S. Department of Energy's Building America team IBACOS built on research previously done in two new-construction unoccupied test houses-one in Pittsburgh, Pennsylvania (Poerschke and Stecher 2014) and one in Fresno, California (Stecher and Poe...
Poerschke, A. Ibacos Innovation
Apr 27, 2016
5 Resources
0 Stars
Publicly accessible
5 Resources
0 Stars
Publicly accessible
Comparative Performance of Four Prototype Mechanical Building Cooling Systems in a Desert Climate
Data and result of approximately fifteen months of monitoring of four houses located in the desert climate of Borrego Springs, California. Four houses were constructed using identical floor plans but differing wall materials, and different cooling systems that were designed to red...
Springer, D. et al Davis Energy
Jul 20, 2016
9 Resources
0 Stars
Publicly accessible
9 Resources
0 Stars
Publicly accessible
Evaluation of the U.S. Department of Energy Challenge Home Program Certification of Production Builders Chicago, IL and Devens, MA
TO4 Task 3.1 K Hovnanian Chicago, IL
DOE Challenge Home Program Certified
Home Constructed and Verified
Specifications
DOE Challenge Home
Building envelope
Ceiling R-49 blown fiberglass, Grade I
Walls 2x4 framing @ 16 o.c. with R-13 fiberglass batts, Grade I
and 1"" R-5 extrude...
Loomis, H. and Kerrigan, P. Building Science Corporation
Apr 27, 2016
6 Resources
0 Stars
Publicly accessible
6 Resources
0 Stars
Publicly accessible
Raleigh Housing Authority Duct Sealing Evaluation
In multifamily and attached buildings, manual duct sealing methods are often impractical or very costly and disruptive because of the difficulty in accessing leakage sites. In this project, two retrofit duct sealing techniques manually applied sealants and injecting a spray sealan...
Dentz, J. et al The Levy Partnership, Inc Systems Building Research Alliance
Apr 27, 2016
18 Resources
0 Stars
Publicly accessible
18 Resources
0 Stars
Publicly accessible
Evaluation of Early Performance Results for Massachusetts Homes in the National Grid Pilot Deep Energy Retrofit Program
In 2009, National Grid started a DER pilot program that offered technical support and financial incentives to qualified Massachusetts homeowners who planned and successfully completed a retrofit that incorporated the performance requirements and goals of the National Grid DER meas...
Neuhauser, K. and Gates, C. Building Science Corporation
Apr 27, 2016
29 Resources
0 Stars
Publicly accessible
29 Resources
0 Stars
Publicly accessible
Comfort in High-Performance Homes in a Hot-Humid Climate
TO5 2.3.2: Large-Scale Temperature Study
Although space-conditioning systems are required to meet standards such as those in the Air Conditioning Contractors of America (ACCA) Manual RS (Rutkowski 1997) and the ASHRAE Standard 55 (ASHRAE 2013) comfort criteria, little is known ab...
Poerschke, A. and Beach, R. Ibacos Innovation
Apr 27, 2016
3 Resources
0 Stars
Publicly accessible
3 Resources
0 Stars
Publicly accessible
Field Testing of Compartmentalization Methods for Multifamily Construction Washington DC
BSC TO5 Task 2.1 Field Testing of Compartmentalization Methods for Multifamily Construction Capitol Heights, MD 20743
A building comprising five vertical townhome units was built in the Washington, D.C., area; the townhomes were three-story slab-on-grade units (1700-2000 ft2) wit...
Ueno, K. and Lstiburek, J. Building Science Corporation
Apr 27, 2016
22 Resources
0 Stars
Publicly accessible
22 Resources
0 Stars
Publicly accessible
Performance and Costs of Ductless Heat Pumps in Marine-Climate High-Performance Homes Habitat for Humanity The Woods
The Washington State University (WSU) Energy Program's Building America (BA) team conducted a case study of a high-performance affordable housing community: The Woods (Figure 1). This BA effort is part of a larger-scale study of 30 homes funded from 2013-2016 by Tacoma Public Util...
Lubliner, M. et al Washington State University
Apr 27, 2016
8 Resources
0 Stars
Publicly accessible
8 Resources
0 Stars
Publicly accessible
Community-Scale Attic Retrofit and Home Energy Upgrade Data Mining Hot Dry Climate
Retrofitting is an essential element of any comprehensive strategy for improving residential energy efficiency. The residential retrofit market is still developing, and program managers must develop innovative strategies to increase uptake and promote economies of scale. Residenti...
Jackson, J. et al Davis Energy
Apr 27, 2016
46 Resources
0 Stars
Publicly accessible
46 Resources
0 Stars
Publicly accessible
Evaluation of Crawlspace Retrofits in Multifamily Buildings
In 2011 and early 2012, Building Science Corporation (BSC) collaborated with Innova Services Corporation on a multifamily community un-vented crawlspace retrofit project at Oakwood Gardens in Lansdale, Pennsylvania. BSC provided design consulting services and pre and post-retrofit...
Rudd, A. Advanced Building Systems
Apr 27, 2016
41 Resources
0 Stars
Publicly accessible
41 Resources
0 Stars
Publicly accessible
Greenbuilt Construction Energy Efficiency Retrofit House Demonstration Sacramento
One of the homes that was part of Sacramento Municipal Utility District's (SMUD) Energy Efficiency Retrofit Demonstration (EERD) project was a 1980's era home in Fair Oaks, California, referred to as the Greenbuilt house, as Greenbuilt Construction completed the retrofit of the h...
Sparn, B. et al Mountain Energy Partnership
Aug 27, 2018
8 Resources
0 Stars
Publicly accessible
8 Resources
0 Stars
Publicly accessible
Analysis of Pre-Retrofit Building and Utility Data Southeast United States
TO4 9.1.2: Comm. Scale Military Housing Upgrades
This project delves into the workflow and results of regression models on monthly and daily utility data (meter readings of electricity consumption), outlining a process for screening and gathering useful results from inverse model...
Beach, R. and Prahl, D. Ibacos Innovation
Apr 27, 2016
12 Resources
0 Stars
In curation
12 Resources
0 Stars
In curation
Chemistry Data for Geothermometry Mapping of Deep Hydrothermal Reservoirs in Southeastern Idaho
This dataset includes chemistry of geothermal water samples of the Eastern Snake River Plain and surrounding area. The samples included in this dataset were collected during the springs and summers of 2014 and 2015. All chemical analysis of the samples were conducted in the Analyt...
Mattson, E. Idaho National Laboratory
Jan 18, 2016
1 Resources
0 Stars
Publicly accessible
1 Resources
0 Stars
Publicly accessible
SiC Diode Test Data
Fabricated SiC diodes are tested in the temperature range of 300 degrees C to 600 degrees C.
Gilbert, G. Sandia National Laboratories
Aug 01, 2014
1 Resources
0 Stars
Publicly accessible
1 Resources
0 Stars
Publicly accessible
Preliminary performance of HT Datalink
Preliminary performance of high-temperature (HT) high-speed (HS) data link at room temperature over 5000 ft of wireline. The data shows ability of the data link to adapt by decreasing speed.
Cieslewski, G. Sandia National Laboratories
Feb 11, 2014
1 Resources
0 Stars
Publicly accessible
1 Resources
0 Stars
Publicly accessible
Surprise Valley Water Geochemical Data
Chemical analyses of thermal and cold ground waters from Surprise Valley, California, compiled from publicly available sources, in collaboration with UC Davis.
Spycher, N. Lawrence Berkeley National Laboratory
Apr 13, 2015
1 Resources
0 Stars
Publicly accessible
1 Resources
0 Stars
Publicly accessible
Conway St Apartments Olive Street Development
In Greenfield, Massachusetts, Olive Street Development transformed an old elementary school building into 12 high-end rental apartments. The developer aimed to get as close to net-zero performance as practical, installing: (1) R-30 high-density spray foam against the brick walls (...
Aldrich, R. and Williamson, J. Steven Winter Associates of the Consortium for Advanced Residential Buildings
Apr 27, 2016
2 Resources
0 Stars
In curation
2 Resources
0 Stars
In curation
Pressure Data from Cranfield CO2 Thermosiphon Test
Pressure data recorded using PANEX pressure gauges at the bottom of wells CFU31-F2 and CFU31-F3.
Freifeld, B. Lawrence Berkeley National Laboratory
Jan 21, 2015
2 Resources
0 Stars
Publicly accessible
2 Resources
0 Stars
Publicly accessible
Shear Induced Permeability Test: Stripa Granite Temperature Pressure and Displacement Data
Spreadsheet containing the raw measured data, calibrated data, and brief explanation of data for Test1 Stripa Granite Geomechanical/Geochemical Test. Stress on fracture ~20.7 MPa.
Kneafsey, T. Lawrence Berkeley National Laboratory
Jun 21, 2014
1 Resources
0 Stars
Publicly accessible
1 Resources
0 Stars
Publicly accessible
Laboratory Evaluation of EGS Shear Stimulation-Test 001
This is the results of an initial setup-shakedon test in order to develop the plumbing system for this test design. a cylinder of granite with offset holes was jacketed and subjected to confining pressure and low temperature (85C) and pore water pressure. Flow through the sample w...
Bauer, S. Sandia National Laboratories
Jul 29, 2014
1 Resources
0 Stars
Publicly accessible
1 Resources
0 Stars
Publicly accessible
Electrification Futures Study Technology Report Figure Data
The file includes the data for figures in the Electrification Futures Study end-use electric technologies report. Additional information on the data can be found in the report.
Jadun. . et al National Renewable Energy Laboratory
Jul 16, 2018
1 Resources
0 Stars
Publicly accessible
1 Resources
0 Stars
Publicly accessible