Search OEDI Data
Showing results 876 - 900 of 2174.
Show
results per page.
Order by:
Available Now:
Research Areas
Accessibility
Data Type
Organization
Source
Utah FORGE: Direct Shear Test Data for Investigating Seismic Precursors to Shear Failure of Fractures
This dataset includes results of direct shear tests to investigate the mechanical and geophysical response of dry and saturated fractures in Indiana limestone and Sierra White granite. Direct shear tests were performed on tensile-induced fractures in Indiana limestone and Sierra W...
Han, K. et al Purdue University
Jun 11, 2024
2 Resources
0 Stars
Publicly accessible
2 Resources
0 Stars
Publicly accessible
Pilgrim Hot Springs Building Dimensions and Energy Modeling
This dataset was created to model the anticipated heating load of a geothermal project in development for the historical site of Pilgrim Hot Springs, and adds to the history of geothermal studies at the site. Models include an historical building (Nun's Quarters), existing modern ...
Garber-Slaght, R. and Coakley, M. National Renewable Energy Laboratory (NREL)
Feb 28, 2024
2 Resources
0 Stars
Publicly accessible
2 Resources
0 Stars
Publicly accessible
Chemical, Calcium Phosphate Cements for Geothermal Wells Corrosion Protection, Bond Strength and Matrix Self-Healing
The data set shows performance of economical calcium phosphate cement (Fondu) blended with fly ash, class F (FAF) in carbon steel corrosion protection tests (corrosion rate, corrosion current and potential), bond and matrix strength, as well as matrix strength recovery after impos...
Sugama, T. Brookhaven National Laboratory
Sep 26, 2017
2 Resources
0 Stars
Publicly accessible
2 Resources
0 Stars
Publicly accessible
Commercial Reference Building: Hospital
Commercial reference buildings provide complete descriptions for whole building energy analysis using EnergyPlus (see "About EnergyPlus" resource link) simulation software. Included here is data pertaining to the reference building type "Hospital" for each of the 16 climate zones ...
Deru, M. et al National Renewable Energy Laboratory
Nov 25, 2014
8 Resources
0 Stars
Publicly accessible
8 Resources
0 Stars
Publicly accessible
Commercial Reference Building: Outpatient Health Care
Commercial reference buildings provide complete descriptions for whole building energy analysis using EnergyPlus (see "About EnergyPlus" resource link) simulation software. Included here is data pertaining to the reference building type "Outpatient Health Care" for each of the 16 ...
Deru, M. et al National Renewable Energy Laboratory
Nov 25, 2014
8 Resources
0 Stars
Publicly accessible
8 Resources
0 Stars
Publicly accessible
Commercial Reference Building: Quick Service Restaurant
Commercial reference buildings provide complete descriptions for whole building energy analysis using EnergyPlus (see "About EnergyPlus" resource link) simulation software. Included here is data pertaining to the reference building type "Quick Service Restaurant" for each of the 1...
Deru, M. et al National Renewable Energy Laboratory
Nov 25, 2014
8 Resources
0 Stars
Publicly accessible
8 Resources
0 Stars
Publicly accessible
Commercial Reference Building: Large Hotel
Commercial reference buildings provide complete descriptions for whole building energy analysis using EnergyPlus (see "About EnergyPlus" resource link) simulation software. Included here is data pertaining to the reference building type "Large Hotel" for each of the 16 climate zon...
Deru, M. et al National Renewable Energy Laboratory
Nov 25, 2014
8 Resources
0 Stars
Publicly accessible
8 Resources
0 Stars
Publicly accessible
Commercial Reference Building: Large Office
Commercial reference buildings provide complete descriptions for whole building energy analysis using EnergyPlus (see "About EnergyPlus" resource link) simulation software. Included here is data pertaining to the reference building type "Large Office" for each of the 16 climate zo...
Deru, M. et al National Renewable Energy Laboratory
Nov 25, 2014
8 Resources
0 Stars
Publicly accessible
8 Resources
0 Stars
Publicly accessible
Commercial Reference Building: Stand-alone Retail
Commercial reference buildings provide complete descriptions for whole building energy analysis using EnergyPlus (see "About EnergyPlus" resource link) simulation software. Included here is data pertaining to the reference building type "Stand-alone Retail" for each of the 16 clim...
Deru, M. et al National Renewable Energy Laboratory
Nov 25, 2014
8 Resources
0 Stars
Publicly accessible
8 Resources
0 Stars
Publicly accessible
Commercial Reference Building: Full Service Restaurant
Commercial reference buildings provide complete descriptions for whole building energy analysis using EnergyPlus (see "About EnergyPlus" resource link) simulation software. Included here is data pertaining to the reference building type "Full Service Restaurant" for each of the 16...
Deru, M. et al National Renewable Energy Laboratory
Nov 25, 2014
8 Resources
0 Stars
Publicly accessible
8 Resources
0 Stars
Publicly accessible
Commercial Reference Building: Medium Office
Commercial reference buildings provide complete descriptions for whole building energy analysis using EnergyPlus (see "About EnergyPlus" resource link) simulation software. Included here is data pertaining to the reference building type "Medium Office" for each of the 16 climate z...
Deru, M. et al National Renewable Energy Laboratory
Nov 25, 2014
8 Resources
0 Stars
Publicly accessible
8 Resources
0 Stars
Publicly accessible
Commercial Reference Building: Small Hotel
Commercial reference buildings provide complete descriptions for whole building energy analysis using EnergyPlus (see "About EnergyPlus" resource link) simulation software. Included here is data pertaining to the reference building type "Small Hotel" for each of the 16 climate zon...
Deru, M. et al National Renewable Energy Laboratory
Nov 25, 2014
8 Resources
0 Stars
Publicly accessible
8 Resources
0 Stars
Publicly accessible
Mini-Split Heat Pump Evaluation and Zero Energy Ready Home Support
This project was created from a partnership between the U.S. Department of Energy's (DOE's) Building America research team, IBACOS, Inc., and a production builder of high-performance homes called Imagine Homes, which is located in San Antonio, Texas-a hot-humid climate. The primar...
Rapport, A. and Herk, A. Ibacos Innovation
Apr 27, 2016
5 Resources
0 Stars
Publicly accessible
5 Resources
0 Stars
Publicly accessible
Improvements in 2016 to Natural Reservoir Analysis in Low-Temperature Geothermal Play Fairway Analysis for the Appalachian Basin
*These files add to and replace same-named files found within Submission 559 (hover over file display names to see actual file names in bottom-left corner of screen)*
The files included in this submission contain all data pertinent to the methods and results of a cohesive multi-st...
Camp, E. Cornell University
Aug 18, 2016
16 Resources
0 Stars
Publicly accessible
16 Resources
0 Stars
Publicly accessible
Utah FORGE 5-2419: Temperature Testing of Proppants for EGS and Stimulation of Electromagnetic Fracture Mapping Using Electrically-Conducive Proppants 2024 Annual Workshop Presentation
This is a presentation on the Temperature Testing of Proppants for EGS and Stimulation of Electromagnetic Fracture Mapping Using Electrically-Conducive Proppants by Stevens Institute of Technology, presented by Cheng Chen. This video slide presentation discusses well controlled la...
Chen, C. et al Energy and Geoscience Institute at the University of Utah
Sep 14, 2024
1 Resources
0 Stars
Publicly accessible
1 Resources
0 Stars
Publicly accessible
Wave Energy Prize 1/50th Testing IOwec Point Absorber
This submission of data includes all the 1/50th scale testing data completed on the Wave Energy Prize for the Iowec team, and includes:
1/50th test data (raw & processed)
1/50th test data video and pictures
1/50th Test plans and testing documents
SSTF_Submission (summarized re...
Scharmen, W. Ricardo Detroit Technical Center
Dec 18, 2015
5 Resources
0 Stars
Publicly accessible
5 Resources
0 Stars
Publicly accessible
Analyzed DTS Data, Guelph, ON Canada
Analyzed DTS datasets from active heat injection experiments in Guelph, ON Canada is included. A .pdf file of images including borehole temperature distributions, temperature difference distributions, temperature profiles, and flow interpretations is included as the primary analyz...
Coleman, T. University of Wisconsin
Jul 01, 2015
5 Resources
0 Stars
Publicly accessible
5 Resources
0 Stars
Publicly accessible
CO2 Push-Pull Dual (Conjugate) Faults Injection Simulations
This submission contains datasets and a final manuscript associated with a project simulating carbon dioxide push-pull into a conjugate fault system modeled after Dixie Valley-
sensitivity analysis of significant parameters and uncertainty prediction by data-worth analysis.
Datas...
Oldenburg, C. et al Lawrence Berkeley National Laboratory
Jul 20, 2017
2 Resources
0 Stars
Publicly accessible
2 Resources
0 Stars
Publicly accessible
Utah FORGE 5-2419: Seismicity-Permeability Relationships Probed via Nonlinear Acoustic Imaging 2024 Annual Workshop Presentation
This is a presentation on Seismicity-Permeability Relationships Probed via Nonlinear Acoustic Imaging by Pennsylvania State University, presented by Derek Elsworth. This video slide presentation discussed controls and acoustic signatures of aseismic through seismic evolution of re...
Elsworth, D. et al Energy and Geoscience Institute at the University of Utah
Sep 05, 2024
1 Resources
0 Stars
Publicly accessible
1 Resources
0 Stars
Publicly accessible
Ridgelines: Department of Interior Definition
This dataset represents ridgelines as defined by the Department of Interior (DOI): "Areas within 660 feet of the top of the ridgeline, where a ridgeline has at least 150 feet of vertical elevation gain with a minimum average slope of 10 percent between the ridgeline and the base."...
Geospatial Data Science, N. National Renewable Energy Laboratory (NREL)
Jan 01, 2024
3 Resources
0 Stars
Publicly accessible
3 Resources
0 Stars
Publicly accessible
National Marine Renewable Energy Center Upgrades LUPA
The data provided is part of a power take off damping optimization study. The power take off damping coefficient was swept from 0 to approximately 7000 N/m/s during a single regular wave test with a real time control of the motor/generator. The generated power from the LUPA (Lab U...
Robertson, B. et al Oregon State University
Oct 12, 2022
5 Resources
0 Stars
Publicly accessible
5 Resources
0 Stars
Publicly accessible
Utah FORGE 2-2439v2: Characterizing In-Situ Stress with Laboratory Modelling and Field Measurements 2024 Annual Workshop Presentation
This is a presentation on A Multi-Component Approach to Characterizing In-Situ Stress at the Utah FORGE Site: Laboratory Modelling and Field Measurements project by The University of Pittsburgh, presented by Andrew Bunger. The project characterizes the stress in the Utah FORGE EGS...
Bunger, A. Energy and Geoscience Institute at the University of Utah
Sep 04, 2024
1 Resources
0 Stars
Publicly accessible
1 Resources
0 Stars
Publicly accessible
Lancaster County Career and Technology Center (LCCTC) Green Homes
With the support of the U.S. Department of Energy (DOE) Building America Program, Home Innovation Research Labs partnered with Lancaster County Career and Technology Center (LCCTC) to build a third new construction test house (NCTH) in Apprentice Green, a community next to the sch...
Kochkin, V. et al Home Innovation Research Labs National Association of Home Builders
Apr 27, 2016
3 Resources
0 Stars
Publicly accessible
3 Resources
0 Stars
Publicly accessible
Snake River (Idaho) Geothermal Drilling Project: Innovative Approaches to Geothermal Exploration
The goal of our project was to test innovative exploration technologies using existing and new data, and to ground-truth these technologies using slim-hole core technology. The slim-hole core allowed us to understand subsurface stratigraphy and alteration in detail, and to correla...
Shervais, J. et al Utah State University
Feb 21, 2014
1 Resources
0 Stars
Publicly accessible
1 Resources
0 Stars
Publicly accessible
Wave Energy Prize 1/50th Testing WECCA Attenuator
This submission of data includes all the 1/50th scale testing data completed on the Wave Energy Prize for the WECCA team, and includes:
1/50th test data (raw & processed)
1/50th test data video and pictures
1/50th Test plans and testing documents
SSTF_Submission (summarized re...
Scharmen, W. Ricardo Detroit Technical Center
Jan 15, 2016
6 Resources
0 Stars
Publicly accessible
6 Resources
0 Stars
Publicly accessible