Search OEDI Data
Showing results 1 - 10 of 10.
Show
results per page.
Order by:
Available Now:
Research Areas
Accessibility
Data Type
Organization
Source
Mini-Split Heat Pump Evaluation and Zero Energy Ready Home Support
This project was created from a partnership between the U.S. Department of Energy's (DOE's) Building America research team, IBACOS, Inc., and a production builder of high-performance homes called Imagine Homes, which is located in San Antonio, Texas-a hot-humid climate. The primar...
Rapport, A. and Herk, A. Ibacos Innovation
Apr 27, 2016
5 Resources
0 Stars
Publicly accessible
5 Resources
0 Stars
Publicly accessible
LBNL Fault Detection and Diagnostics Datasets
These datasets can be used to evaluate and benchmark the performance accuracy of Fault Detection and Diagnostics (FDD) algorithms or tools. It contains operational data from simulation, laboratory experiments, and field measurements from real buildings for seven HVAC systems/equip...
Granderson, J. et al Lawrence Berkeley National Laboratory
Aug 01, 2022
5 Resources
0 Stars
Publicly accessible
5 Resources
0 Stars
Publicly accessible
Bouira University Digital Space
Description archive of our university and/or Remarks:
The University of Bouira offers visitors from Bouira University Digital Space a free downloadable files (memories doctoral, master, master, courses in different technological and literary disciplines, proceedings of scientif...
Chettabi, . National Renewable Energy Laboratory
Jan 08, 2000
1 Resources
0 Stars
In curation
1 Resources
0 Stars
In curation
EPA: ENERGY STAR Labeled Buildings and Plants (2009)
This dataset contains Buildings and Plants labeled ENERGY STAR for 2009. It also contains a list of the buildings in the top 25 cities.
### License Info
From http://www.energystar.gov/index.cfm?c=home.privacy_policy
Information presented on this Web site is considered publi...
Brodt-Giles, D. and (EPA), E. National Renewable Energy Laboratory
Jul 29, 2014
2 Resources
0 Stars
In curation
2 Resources
0 Stars
In curation
NorthernStar Zero Energy Ready Homes
This is a repository for all NorthernSTAR Zero Energy Ready certified homes.
Amaris Homes Model Home St. Paul, MN 55110
Description: Model home completed September 2013
The DOE Zero Energy Ready Home Case Study looks to study and eventually design zero net energy homes in cold we...
Huelman, P. University of Minnesota NorthernSTAR Building America Partnership
Apr 27, 2016
20 Resources
0 Stars
Publicly accessible
20 Resources
0 Stars
Publicly accessible
Evaluation of the U.S. Department of Energy Challenge Home Program Certification of Production Builders Chicago, IL and Devens, MA
TO4 Task 3.1 K Hovnanian Chicago, IL
DOE Challenge Home Program Certified
Home Constructed and Verified
Specifications
DOE Challenge Home
Building envelope
Ceiling R-49 blown fiberglass, Grade I
Walls 2x4 framing @ 16 o.c. with R-13 fiberglass batts, Grade I
and 1"" R-5 extrude...
Loomis, H. and Kerrigan, P. Building Science Corporation
Apr 27, 2016
6 Resources
0 Stars
Publicly accessible
6 Resources
0 Stars
Publicly accessible
Super-Resolution for Renewable Resource Data and Urban Heat Islands (Sup3rUHI)
Super-Resolution for Renewable Resource Data and Urban Heat Islands (Sup3rUHI) introduces machine learning methods to incorporate high-resolution Urban Heat Island (UHI) effects into low-resolution historical reanalysis and future climate model datasets. The dataset includes model...
Buster, G. et al The National Renewable Energy Lab (NREL)
Oct 16, 2024
2 Resources
0 Stars
Curated
2 Resources
0 Stars
Curated
Spray Foam Exterior Insulation with Stand-Off Furring New York
IBACOS and Green Homes America 1 (GHA) collaborated with the New York State Energy Research and Development Authority (NYSERDA) Advanced Buildings Program to research a variation of a commercial curtain wall assembly for residential construction as part of a comprehensive whole-ho...
Rapport, A. et al Ibacos Innovation
Apr 27, 2016
2 Resources
0 Stars
Publicly accessible
2 Resources
0 Stars
Publicly accessible
Monitoring of Double-Stud Wall Moisture Conditions in the Northeast
BSC TO5 Task 2.2 Monitoring of Double Stud Wall Moisture Conditions in the Northeast
Field test data available for wood moisture contents, temperature, and relative humidity.
STRUCTURE House Devens, MA 01432
Three double-stud assemblies were compared: 12-in. ocSPF, 12-in. cellulo...
Ueno, K. Building Science Corporation
Apr 27, 2016
2 Resources
0 Stars
Publicly accessible
2 Resources
0 Stars
Publicly accessible
Field Testing of Compartmentalization Methods for Multifamily Construction Washington DC
BSC TO5 Task 2.1 Field Testing of Compartmentalization Methods for Multifamily Construction Capitol Heights, MD 20743
A building comprising five vertical townhome units was built in the Washington, D.C., area; the townhomes were three-story slab-on-grade units (1700-2000 ft2) wit...
Ueno, K. and Lstiburek, J. Building Science Corporation
Apr 27, 2016
22 Resources
0 Stars
Publicly accessible
22 Resources
0 Stars
Publicly accessible