OpenEI: Energy Information
  • Open Energy Data Initiative (OEDI)
  • My User
    • Sign Up
    • Login
OEDI logo
  • Data
    • View All Submissions
    • Data Lakes
    • Submit Data
  • Help
    • Frequently Asked Questions
    • Data Submission Best Practices
    • Data Submission Tutorial Videos
    • Contact OpenEI Help
  • About
  • Search

Search OEDI Data

Showing results 1 - 25 of 306.
Show results per page.
Order by:
Available Now:
Filters
Research Areas
Accessibility
Data Type
Organization
Source
"building types"×

Simulated Load Profiles for DOE Commercial Reference Buildings (17 Years Using NSRDB Data)

This data set consists of simulated load profiles (1998-2014, 30 minute profile) for commercial customers using the Pacific Northwest National Laboratory residential prototype building models and the US Department of Energy's (DOE) commercial reference building models made for Ene...
Darghouth, N. Lawrence Berkeley National Laboratory
Sep 16, 2016
23 Resources
1 Stars
In curation

Commercial Reference Building: Full Service Restaurant

Commercial reference buildings provide complete descriptions for whole building energy analysis using EnergyPlus (see "About EnergyPlus" resource link) simulation software. Included here is data pertaining to the reference building type "Full Service Restaurant" for each of the 16...
Deru, M. et al National Renewable Energy Laboratory
Nov 25, 2014
8 Resources
0 Stars
Publicly accessible

Commercial Reference Building: Supermarket

Commercial reference buildings provide complete descriptions for whole building energy analysis using EnergyPlus (see "About EnergyPlus" resource link) simulation software. Included here is data pertaining to the reference building type "Supermarket" for each of the 16 climate zon...
Deru, M. et al National Renewable Energy Laboratory
Nov 25, 2014
8 Resources
0 Stars
Publicly accessible

Commercial Reference Building: Warehouse

Commercial reference buildings provide complete descriptions for whole building energy analysis using EnergyPlus (see "About EnergyPlus" resource link) simulation software. Included here is data pertaining to the reference building type "Warehouse" for each of the 16 climate zones...
Deru, M. et al National Renewable Energy Laboratory
Nov 25, 2014
8 Resources
0 Stars
Publicly accessible

Commercial Reference Building: Midrise Apartment

Commercial reference buildings provide complete descriptions for whole building energy analysis using EnergyPlus (see "About EnergyPlus" resource link) simulation software. Included here is data pertaining to the reference building type "Midrise Apartment" for each of the 16 clima...
Deru, M. et al National Renewable Energy Laboratory
Nov 25, 2014
8 Resources
0 Stars
Publicly accessible

Commercial Reference Building: Secondary School

Commercial reference buildings provide complete descriptions for whole building energy analysis using EnergyPlus (see "About EnergyPlus" resource link) simulation software. Included here is data pertaining to the reference building type "Secondary School" for each of the 16 climat...
Deru, M. et al National Renewable Energy Laboratory
Nov 25, 2014
8 Resources
0 Stars
Publicly accessible

Commercial Reference Building: Primary School

Commercial reference buildings provide complete descriptions for whole building energy analysis using EnergyPlus (see "About EnergyPlus" resource link) simulation software. Included here is data pertaining to the reference building type "Primary School" for each of the 16 climate ...
Deru, M. et al National Renewable Energy Laboratory
Nov 25, 2014
8 Resources
0 Stars
Publicly accessible

Commercial Reference Building: Strip Mall

Commercial reference buildings provide complete descriptions for whole building energy analysis using EnergyPlus (see "About EnergyPlus" resource link) simulation software. Included here is data pertaining to the reference building type "Strip Mall" for each of the 16 climate zone...
Deru, M. et al National Renewable Energy Laboratory
Nov 25, 2014
8 Resources
0 Stars
Publicly accessible

Commercial Reference Building: Small Office

Commercial reference buildings provide complete descriptions for whole building energy analysis using EnergyPlus (see "About EnergyPlus" resource link) simulation software. Included here is data pertaining to the reference building type "Small Office" for each of the 16 climate zo...
Deru, M. et al National Renewable Energy Laboratory
Nov 25, 2014
8 Resources
0 Stars
Publicly accessible

Commercial Reference Building: Outpatient Health Care

Commercial reference buildings provide complete descriptions for whole building energy analysis using EnergyPlus (see "About EnergyPlus" resource link) simulation software. Included here is data pertaining to the reference building type "Outpatient Health Care" for each of the 16 ...
Deru, M. et al National Renewable Energy Laboratory
Nov 25, 2014
8 Resources
0 Stars
Publicly accessible

Commercial Reference Building: Quick Service Restaurant

Commercial reference buildings provide complete descriptions for whole building energy analysis using EnergyPlus (see "About EnergyPlus" resource link) simulation software. Included here is data pertaining to the reference building type "Quick Service Restaurant" for each of the 1...
Deru, M. et al National Renewable Energy Laboratory
Nov 25, 2014
8 Resources
0 Stars
Publicly accessible

Commercial Reference Building: Large Office

Commercial reference buildings provide complete descriptions for whole building energy analysis using EnergyPlus (see "About EnergyPlus" resource link) simulation software. Included here is data pertaining to the reference building type "Large Office" for each of the 16 climate zo...
Deru, M. et al National Renewable Energy Laboratory
Nov 25, 2014
8 Resources
0 Stars
Publicly accessible

Commercial Reference Building: Small Hotel

Commercial reference buildings provide complete descriptions for whole building energy analysis using EnergyPlus (see "About EnergyPlus" resource link) simulation software. Included here is data pertaining to the reference building type "Small Hotel" for each of the 16 climate zon...
Deru, M. et al National Renewable Energy Laboratory
Nov 25, 2014
8 Resources
0 Stars
Publicly accessible

Commercial Reference Building: Hospital

Commercial reference buildings provide complete descriptions for whole building energy analysis using EnergyPlus (see "About EnergyPlus" resource link) simulation software. Included here is data pertaining to the reference building type "Hospital" for each of the 16 climate zones ...
Deru, M. et al National Renewable Energy Laboratory
Nov 25, 2014
8 Resources
0 Stars
Publicly accessible

Commercial Reference Building: Stand-alone Retail

Commercial reference buildings provide complete descriptions for whole building energy analysis using EnergyPlus (see "About EnergyPlus" resource link) simulation software. Included here is data pertaining to the reference building type "Stand-alone Retail" for each of the 16 clim...
Deru, M. et al National Renewable Energy Laboratory
Nov 25, 2014
8 Resources
0 Stars
Publicly accessible

Commercial Reference Building: Large Hotel

Commercial reference buildings provide complete descriptions for whole building energy analysis using EnergyPlus (see "About EnergyPlus" resource link) simulation software. Included here is data pertaining to the reference building type "Large Hotel" for each of the 16 climate zon...
Deru, M. et al National Renewable Energy Laboratory
Nov 25, 2014
8 Resources
0 Stars
Publicly accessible

Commercial Reference Building: Medium Office

Commercial reference buildings provide complete descriptions for whole building energy analysis using EnergyPlus (see "About EnergyPlus" resource link) simulation software. Included here is data pertaining to the reference building type "Medium Office" for each of the 16 climate z...
Deru, M. et al National Renewable Energy Laboratory
Nov 25, 2014
8 Resources
0 Stars
Publicly accessible

Control Strategies to Reduce the Energy Consumption of Central Domestic Hot Water Systems

Domestic hot water (DHW) is the second-largest energy end use in U.S. buildings; it is exceeded only by space conditioning. In this study, the U.S. Department of Energy's Building America research team Advanced Research Integrated Energy Solutions installed and tested two types o...
Dentz, J. et al The Levy Partnership, Inc Systems Building Research Alliance
Apr 27, 2016
3 Resources
0 Stars
Publicly accessible

Building Component Library

The Building Component Library (BCL) is the U.S. Department of Energy's comprehensive online searchable library of energy modeling building blocks and descriptive metadata. Novice users and seasoned practitioners can use the freely available and uniquely identifiable components to...
Long, N. and Fleming, K. National Renewable Energy Laboratory
Nov 25, 2014
1 Resources
0 Stars
Publicly accessible

Buildings Performance Database

The Buildings Performance Database (BPD) unlocks the power of building energy performance data. The platform enables users to perform statistical analysis on an anonymous dataset of tens of thousands of commercial and residential buildings from across the country. Users can compar...
Contact, B. and (EERE), O. Office of Energy Efficiency & Renewable Energy
Nov 25, 2014
2 Resources
0 Stars
In curation

Commercial and Residential Hourly Load Profiles for all TMY3 Locations in the United States

Note: This dataset has been superseded by the dataset found at "End-Use Load Profiles for the U.S. Building Stock" (submission 4520; linked in the submission resources), which is a comprehensive and validated representation of hourly load profiles in the U.S. commercial and reside...
Ong, S. and Clark, N. National Renewable Energy Laboratory
Nov 25, 2014
22 Resources
1 Stars
Publicly accessible

Raleigh Housing Authority Duct Sealing Evaluation

In multifamily and attached buildings, manual duct sealing methods are often impractical or very costly and disruptive because of the difficulty in accessing leakage sites. In this project, two retrofit duct sealing techniques manually applied sealants and injecting a spray sealan...
Dentz, J. et al The Levy Partnership, Inc Systems Building Research Alliance
Apr 27, 2016
18 Resources
0 Stars
Publicly accessible

NorthernSTAR 1.5-Story Demonstration House of Cold Climate Solutions for Affordable Housing

This is a NorthernSTAR renovation project for Urban Homeworks incorporating installation of a combination space and water heater, Overcoat insulation retrofit on the roof, and Excavationless foundation insulation retrofit. STRUCTURE 1401 North 16th Ave Minneapolis, MN 55411 Var...
Jacobson, R. et al University of Minnesota NorthernSTAR Building America Partnership
Apr 27, 2016
12 Resources
0 Stars
Publicly accessible

Analysis of Joist Masonry Moisture Content Monitoring

BSC TO5 Task 7.2 Analysis of Joist Masonry Moisture Content Monitoring House Lawrence, MA 01840 This work involved the field monitoring of embedded wood joist ends in a solid brick building in zone 5A that was retrofitted with interior insulation. Eleven joists throughout the bui...
Ueno, K. Building Science Corporation
Apr 27, 2016
3 Resources
0 Stars
Publicly accessible

End-Use Load Profiles for the U.S. Building Stock

The United States is embarking on an ambitious transition to a 100% clean energy economy by 2050, which will require improving the flexibility of electric grids. One way to achieve grid flexibility is to shed or shift demand to align with changing grid needs. To facilitate this, i...
Wilson, E. et al National Renewable Energy Laboratory (NREL)
Oct 14, 2021
8 Resources
2 Stars
Publicly accessible
12345Next >>
  • About the Open Energy Data Initiative
  • Partners & Sponsors
  • Disclaimers
  • Developer Services
  • The OEDI Data Lake is a centralized repository of datasets aggregated from the U.S. Department of Energy’s Programs, Offices, and National Laboratories.
  • Content is available under Creative Commons Attribution 4.0 unless otherwise noted.

Privacy Policy Notification

This site uses cookies to store and share user preferences with other OpenEI sites, and uses Google Analytics to collect anonymous user information such as which pages are visited, for how often, and what searches or other webpages may have led users here. You can prevent Google Analytics from recognizing you on return visits to this site by disabling cookies on your browser or by installing a Google Analytics Opt-out Browser Add-on. By clicking "Accept" you agree this site can store cookies on your device and disclose information to OpenEI and Google Analytics in accordance with our privacy policy.

OpenEI Privacy Policy Google Analytics Terms of Service