Search OEDI Data
Showing results 1 - 25 of 76.
Show
results per page.
Order by:
Available Now:
Research Areas
Accessibility
Data Type
Organization
Source
Ocean Thermal Energy Conversion (OTEC) | Seawater Cooling Depth Profile 14ºC (Annual Average)
This shapefile represents the annual average depth profile to reach water at a temperature of 14ºC.
Sea water cooling can be used for industrial or residential cooling needs where heat must be rejected. A typical resource for direct air-conditioning applications is no warmer t...
Langle, N. and Laboratory, N. National Renewable Energy Laboratory
Nov 25, 2014
2 Resources
0 Stars
In curation
2 Resources
0 Stars
In curation
Ocean Thermal Energy Conversion (OTEC) | Seawater Cooling Depth Profile 14ºC (Summer Average)
This shapefile represents the seasonal summer depth profile to reach water at a temperature of 14ºC.
Sea water cooling can be used for industrial or residential cooling needs where heat must be rejected. A typical resource for direct air-conditioning applications is no warmer ...
Langle, N. and Laboratory, N. National Renewable Energy Laboratory
Nov 25, 2014
2 Resources
0 Stars
In curation
2 Resources
0 Stars
In curation
Ocean Thermal Energy Conversion (OTEC) | Seawater Cooling Depth Profile 14ºC (Winter Average)
This shapefile represents the seasonal winter depth profile to reach water at a temperature of 14ºC.
Sea water cooling can be used for industrial or residential cooling needs where heat must be rejected. A typical resource for direct air-conditioning applications is no warmer ...
Langle, N. and Laboratory, N. National Renewable Energy Laboratory
Nov 25, 2014
2 Resources
0 Stars
In curation
2 Resources
0 Stars
In curation
Ocean Thermal Energy Conversion (OTEC) | Seawater Cooling Depth Profile 20ºC (Annual Average)
This shapefile represents the annual average depth profile to reach water at a temperature of 20ºC.
Sea water cooling can be used for industrial or residential cooling needs where heat must be rejected. A typical resource for direct air-conditioning applications is no warmer t...
Langle, N. and Laboratory, N. National Renewable Energy Laboratory
Nov 25, 2014
2 Resources
0 Stars
In curation
2 Resources
0 Stars
In curation
Ocean Thermal Energy Conversion (OTEC) | Seawater Cooling Depth Profile 20ºC (Summer Average)
This shapefile represents the seasonal summer depth profile to reach water at a temperature of 20ºC.
Sea water cooling can be used for industrial or residential cooling needs where heat must be rejected. A typical resource for direct air-conditioning applications is no warmer ...
Langle, N. and Laboratory, N. National Renewable Energy Laboratory
Nov 25, 2014
2 Resources
0 Stars
In curation
2 Resources
0 Stars
In curation
Ocean Thermal Energy Conversion (OTEC) | Seawater Cooling Depth Profile 20ºC (Winter Average)
This shapefile represents the seasonal winter depth profile to reach water at a temperature of 20ºC.
Sea water cooling can be used for industrial or residential cooling needs where heat must be rejected. A typical resource for direct air-conditioning applications is no warmer ...
Langle, N. and Laboratory, N. National Renewable Energy Laboratory
Nov 25, 2014
2 Resources
0 Stars
In curation
2 Resources
0 Stars
In curation
Ocean Thermal Energy Conversion (OTEC) | Seawater Cooling Depth Profile 8ºC (Annual Average)
This shapefile represents the annual average depth profile to reach water at a temperature of 8ºC.
Sea water cooling can be used for industrial or residential cooling needs where heat must be rejected. A typical resource for direct air-conditioning applications is no warmer th...
Langle, N. and Laboratory, N. National Renewable Energy Laboratory
Nov 25, 2014
2 Resources
0 Stars
In curation
2 Resources
0 Stars
In curation
Ocean Thermal Energy Conversion (OTEC) | Seawater Cooling Depth Profile 8ºC (Summer Average)
This shapefile represents the seasonal summer depth profile to reach water at a temperature of 8ºC.
Sea water cooling can be used for industrial or residential cooling needs where heat must be rejected. A typical resource for direct air-conditioning applications is no warmer t...
Langle, N. and Laboratory, N. National Renewable Energy Laboratory
Nov 25, 2014
2 Resources
0 Stars
In curation
2 Resources
0 Stars
In curation
Ocean Thermal Energy Conversion (OTEC) | Seawater Cooling Depth Profile 8ºC (Winter Average)
This shapefile represents the seasonal winter depth profile to reach water at a temperature of 8ºC.
Sea water cooling can be used for industrial or residential cooling needs where heat must be rejected. A typical resource for direct air-conditioning applications is no warmer t...
Langle, N. and Laboratory, N. National Renewable Energy Laboratory
Nov 25, 2014
2 Resources
0 Stars
In curation
2 Resources
0 Stars
In curation
City and County Vehicle Inventories
This light-duty vehicle inventory dataset provides information on vehicle registrations by vehicle type (car vs. truck), fuel type, and model year showing the changes in adoption trends over time and average fuel economies.
This data is part of a suite of state and local energy ...
Day, M. National Renewable Energy Laboratory
Dec 21, 2019
4 Resources
1 Stars
Curated
4 Resources
1 Stars
Curated
City and County Commercial Building Inventories
The Commercial Building Inventories provide modeled data on commercial building type, vintage, and area for each U.S. city and county. Please note this data is modeled and more precise data may be available through county assessors or other sources. Commercial building stock data ...
Day, M. et al National Renewable Energy Laboratory
Apr 01, 2020
9 Resources
0 Stars
Curated
9 Resources
0 Stars
Curated
City and County Energy Profiles
The City and County Energy Profiles lookup table provides modeled electricity and natural gas consumption and expenditures, on-road vehicle fuel consumption, vehicle miles traveled, and associated emissions for each U.S. city and county. Please note this data is modeled and more p...
Day, M. National Renewable Energy Laboratory
Dec 20, 2019
5 Resources
1 Stars
Curated
5 Resources
1 Stars
Curated
Renewable Electricity Procurement Options Data
The Procurement Analysis Tool (PAT) was developed at NREL to help organizations explore renewable energy options that align with their goals. Users input facility data and answer goal-oriented questions. PAT analyzes this information to identify potential wind, solar, or storage r...
Day, M. National Renewable Energy Laboratory
Nov 12, 2019
5 Resources
0 Stars
Curated
5 Resources
0 Stars
Curated
Commercial and Residential Hourly Load Profiles for all TMY3 Locations in the United States
Note: This dataset has been superseded by the dataset found at "End-Use Load Profiles for the U.S. Building Stock" (submission 4520; linked in the submission resources), which is a comprehensive and validated representation of hourly load profiles in the U.S. commercial and reside...
Ong, S. and Clark, N. National Renewable Energy Laboratory
Nov 25, 2014
22 Resources
0 Stars
Curated
22 Resources
0 Stars
Curated
AASG Wells Data for the EGS Test Site Planning and Analysis Task
AASG Wells Data for the EGS Test Site Planning and Analysis Task
Temperature measurement data obtained from boreholes for the Association of American State Geologists (AASG) geothermal data project. Typically bottomhole temperatures are recorded from log headers, and this informat...
Augustine, C. National Renewable Energy Laboratory
Oct 09, 2013
1 Resources
0 Stars
Publicly accessible
1 Resources
0 Stars
Publicly accessible
Low-Temperature Geothermal Geospatial Datasets: An Example from Alaska
This project is a component of a broader effort focused on geothermal heating and cooling (GHC) with the aim of illustrating the numerous benefits of incorporating GHC and geothermal heat exchange (GHX) into community energy planning and national decarbonization strategies. To bet...
Davalos Elizondo, E. et al National Renewable Energy Laboratory
Feb 06, 2023
6 Resources
0 Stars
Publicly accessible
6 Resources
0 Stars
Publicly accessible
US Low-Temperature EGS Resource Potential Estimate
Shapefile of shallow, low-temperature EGS resources for the United States, and accompanying paper (submitted to GRC 2016) describing the methodology and analysis. These data are part of a very rough estimate created for use in the U.S. Department of Energy Geothermal Technology O...
Mullane, M. et al National Renewable Energy Laboratory
Jun 30, 2016
2 Resources
0 Stars
Publicly accessible
2 Resources
0 Stars
Publicly accessible
Low Temperature Geothermal Resource Assessment for Desalination in United States
This data is a compilation of well observations from the Southern Methodist University (SMU) and Association of American State Geologists (AASG), location of identified low temperature geothermal systems from United States Geological Survey (USGS), and low temperature geothermal w...
Akar, S. and Turchi, C. National Renewable Energy Laboratory
Sep 30, 2016
6 Resources
0 Stars
Publicly accessible
6 Resources
0 Stars
Publicly accessible
Low-Temperature Hydrothermal Resource Potential Estimate
Compilation of data (spreadsheet and shapefiles) for several low-temperature resource types, including isolated springs and wells, delineated area convection systems, sedimentary basins and coastal plains sedimentary systems. For each system, we include estimates of the accessible...
Mullane, M. et al National Renewable Energy Laboratory
Jun 30, 2016
3 Resources
0 Stars
Publicly accessible
3 Resources
0 Stars
Publicly accessible
Indoor and Outdoor Temperature data
We have used three LM35 temperature sensors to sense indoor and outdoor temperature at Bangkok University , Thailand. Two sensors (Sensor A and B)were placed in a air-conditioned room in the Engineering Building (6th Floor) and kept once sensor outside (Sensor C)
Maduranga, P. National Renewable Energy Laboratory
Jan 21, 2018
1 Resources
0 Stars
In curation
1 Resources
0 Stars
In curation
Low-Temperature Hydrothermal Resource Potential Estimate
Compilation of data (spreadsheet and shapefiles) for several low-temperature resource types, including isolated springs and wells, delineated area convection systems, sedimentary basins and coastal plains sedimentary systems. For each system, we include estimates of the accessibl...
Mullane, M. et al National Renewable Energy Laboratory
Jun 30, 2016
4 Resources
0 Stars
Publicly accessible
4 Resources
0 Stars
Publicly accessible
Hourly Dynamic Line Ratings for Existing Transmission Across the Contiguous United States (Preliminary)
This dataset provides estimated hourly dynamic line ratings for ~84,000 transmission lines across the contiguous United States from 2007-2013. The calculation methods are described in the presentation linked below, and the associated open-source Python code repository is linked in...
Obika, K. et al National Renewable Energy Laboratory
Sep 25, 2024
16 Resources
0 Stars
Curated
16 Resources
0 Stars
Curated
Sedimentary Geothermal Feasibility in Eastern Nevada and Millard County, Utah Well Databases
In order to gather data to assess sedimentary geothermal feasibility in Nevada and Utah, state oil and gas and geothermal databases were serached for well files and well logs. Well data from the Nevada Bureau of Mines and Geology oil and gas and geothermal databases was mined for ...
Taverna, N. National Renewable Energy Laboratory
Nov 30, 2019
12 Resources
0 Stars
Publicly accessible
12 Resources
0 Stars
Publicly accessible
Updated U.S. Low-Temperature Heating and Cooling Demand by County and Sector
This dataset includes U.S. low-temperature heating and cooling demand at the county level in major end-use sectors: residential, commercial, manufacturing, agricultural, and data centers. Census division-level end-use energy consumption, expenditure, and commissioned power databas...
Oh, H. and Beckers, K. National Renewable Energy Laboratory
Dec 31, 2022
6 Resources
0 Stars
Publicly accessible
6 Resources
0 Stars
Publicly accessible
Long-term Average Surface Temperatures in England (1772 2009)
This dataset, made available by the UK Department of Energy and Climate Change (DECC), shows the difference between the yearly central England temperature for years 1772 through 2009 and the 1961 1990 baseline (1961 1990 Central England average after smoothing). It also shows the ...
Hallett, K. and (DECC), U. National Renewable Energy Laboratory
Mar 11, 2010
2 Resources
0 Stars
In curation
2 Resources
0 Stars
In curation