Search OEDI Data
Showing results 51 - 57 of 57.
Show
results per page.
Order by:
Available Now:
Research Areas
Accessibility
Data Type
Organization
Source
Greenbelt Homes Pilot Program: Summary of Building Envelope Retrofits, Planned HVAC Equipment Upgrades, and Energy Savings
In fall 2010, Greenbelt Homes, Inc. (GHI) a 1,566-home cooperative of circa 1930-1940 homes in Greenbelt, Maryland, undertook a multiyear pilot energy efficiency retrofit project. GHI established this pilot project as a basis for decision making for the rollout of a decade-long co...
Mallay, D. et al Home Innovation Research Labs National Association of Home Builders
Jul 21, 2016
4 Resources
0 Stars
Publicly accessible
4 Resources
0 Stars
Publicly accessible
NorthernSTAR 1.5-Story Demonstration House of Cold Climate Solutions for Affordable Housing
This is a NorthernSTAR renovation project for Urban Homeworks incorporating installation of a combination space and water heater, Overcoat insulation retrofit on the roof, and Excavationless foundation insulation retrofit.
STRUCTURE 1401 North 16th Ave Minneapolis, MN 55411
Var...
Jacobson, R. et al University of Minnesota NorthernSTAR Building America Partnership
Apr 27, 2016
12 Resources
0 Stars
Publicly accessible
12 Resources
0 Stars
Publicly accessible
Measure Guideline: Deep Energy Enclosure Retrofit for Interior Insulation of Masonry Walls and Flat Roofs
Measure Guideline: Deep Energy Enclosure Retrofit for Zero Energy Ready House Flat Roofs
BSC TO5 Task 7.4 Deep Energy Enclosure Retrofit (DEER) for Interior Insulation of Masonry Walls
Lawrence, MA 01840
This Measure Guideline describes a deep energy enclosure retrofit solution ...
Musunuru, S. et al Building Science Corporation
Apr 27, 2016
5 Resources
0 Stars
Publicly accessible
5 Resources
0 Stars
Publicly accessible
Comparative Performance of Four Prototype Mechanical Building Cooling Systems in a Desert Climate
Data and result of approximately fifteen months of monitoring of four houses located in the desert climate of Borrego Springs, California. Four houses were constructed using identical floor plans but differing wall materials, and different cooling systems that were designed to red...
Springer, D. et al Davis Energy
Jul 20, 2016
9 Resources
0 Stars
Curated
9 Resources
0 Stars
Curated
Analysis of Pre-Retrofit Building and Utility Data Southeast United States
TO4 9.1.2: Comm. Scale Military Housing Upgrades
This project delves into the workflow and results of regression models on monthly and daily utility data (meter readings of electricity consumption), outlining a process for screening and gathering useful results from inverse model...
Beach, R. and Prahl, D. Ibacos Innovation
Apr 27, 2016
12 Resources
0 Stars
In curation
12 Resources
0 Stars
In curation
Raleigh Housing Authority Duct Sealing Evaluation
In multifamily and attached buildings, manual duct sealing methods are often impractical or very costly and disruptive because of the difficulty in accessing leakage sites. In this project, two retrofit duct sealing techniques manually applied sealants and injecting a spray sealan...
Dentz, J. et al The Levy Partnership, Inc Systems Building Research Alliance
Apr 27, 2016
18 Resources
0 Stars
Publicly accessible
18 Resources
0 Stars
Publicly accessible
Solar Row Zero Energy Townhomes Boulder, CO
Wonderland Development has constructed a new "near zero energy" row home design in North Boulder consisting of 9 units: one 5-plex and two duplexes. NREL has performed short-term tests and installed long-term monitoring equipment in three of these units. Two of these units used a ...
Norton, P. et al National Renewable Energy Laboratory
Sep 27, 2016
11 Resources
0 Stars
Publicly accessible
11 Resources
0 Stars
Publicly accessible