The Performance House: A Cold Climate Challenge Home Old Greenwich
Working with builder partners on test homes allows for vetting of whole-house building strategies to eliminate any potential unintended consequences prior to implementing these solution packages on a production scale. To support this research, the Consortium for Advanced Residenti...
Williamson, J. et al Steven Winter Associates of the Consortium for Advanced Residential Buildings
Apr 27, 2016
4 Resources
0 Stars
Publicly accessible
4 Resources
0 Stars
Publicly accessible
Evaluation of the U.S. Department of Energy Challenge Home Program Certification of Production Builders Chicago, IL and Devens, MA
TO4 Task 3.1 K Hovnanian Chicago, IL
DOE Challenge Home Program Certified
Home Constructed and Verified
Specifications
DOE Challenge Home
Building envelope
Ceiling R-49 blown fiberglass, Grade I
Walls 2x4 framing @ 16 o.c. with R-13 fiberglass batts, Grade I
and 1"" R-5 extrude...
Loomis, H. and Kerrigan, P. Building Science Corporation
Apr 27, 2016
6 Resources
0 Stars
Publicly accessible
6 Resources
0 Stars
Publicly accessible
Modular Zero Energy Ready Homes: Bright Built Maine
Kaplan Thompson Architects (KTA) has specialized in sustainable, energy-efficient buildings, and they have designed several custom, zero-energy homes in New England. These zero-energy projects have generally been high-end, custom homes with budgets that could accommodate advanced ...
Aldrich, R. and Butterfield, K. Steven Winter Associates of the Consortium for Advanced Residential Buildings
Apr 27, 2016
2 Resources
0 Stars
Publicly accessible
2 Resources
0 Stars
Publicly accessible
NorthernSTAR Project Overcoat: Exterior Insulation Strategies for 1.5-Story Roof Applications in Cold Climates
This is a repository for all NorthernSTAR Overcoat insulation retrofit projects. Both houses received Overcoat insulation retrofit on roof only, performed by Cocoon Insulation.
1 St. Louis Park house St. Louis Park, MN
2 Edina house Edina, MN
In this second study, the team wishe...
Jacobson, R. et al University of Minnesota NorthernSTAR Building America Partnership
Apr 27, 2016
10 Resources
0 Stars
Publicly accessible
10 Resources
0 Stars
Publicly accessible
Air Leakage and Air Transfer Between Garage and Living Space
This research project focused on evaluation of air transfer between the garage and living space in a single-family detached home constructed by a production homebuilder in compliance with the 2009 International Residential Code and the 2009 International Energy Conservation Code. ...
Rudd, A. and Kerrigan, P. Advanced Building Systems
Apr 27, 2016
2 Resources
0 Stars
Publicly accessible
2 Resources
0 Stars
Publicly accessible
EcoVillage: A Net Zero Energy Ready Community Ithaca Crawlspace
The U.S. Department of Energy's (DOE) Building America team, Consortium for Residential Buildings (CARB), is working with the EcoVillage cohousing community in Ithaca, New York, on the Third Residential EcoVillage Experience neighborhood. This community-scale project consists of 4...
Arena, L. et al Steven Winter Associates of the Consortium for Advanced Residential Buildings
Apr 27, 2016
3 Resources
0 Stars
Publicly accessible
3 Resources
0 Stars
Publicly accessible
Better Buildings Neighborhood Program Single-Family Home Upgrade Project Dataset
Building project data for 75,110 single-family homes upgraded between July 1, 2010, and September 30, 2013 from the Better Building Neighborhood Program. This dataset includes a documentation file and three data tables. Reported data for some elements have been transformed and dat...
Hoffmeyer, D. U.S. Department of Energy, Office of Energy Efficiency and Renewable Energy
May 01, 2015
5 Resources
0 Stars
Curated
5 Resources
0 Stars
Curated
Field Testing Unvented Roofs with Asphalt Shingles in Cold and Hot-humid Climates
BSC TO5 Task 7.1 Field Testing Unvented Roofs with Asphalt Shingles in Cold Climates Bolingbrook, IL 60440
BSC TO5 Task 7.1 Field Testing Unvented Roofs with Asphalt Shingles in Hot-Humid Climates Friendswood, TX 77546
To understand the long-term moisture performance of unvented ...
Ueno, K. and Lstiburek, J. Building Science Corporation
Apr 27, 2016
3 Resources
0 Stars
Publicly accessible
3 Resources
0 Stars
Publicly accessible
Evaluation of the Performance of Houses With and Without Supplemental Dehumidification in a Hot-Humid Climate
Understanding indoor humidity conditions in low energy homes in hot-humid climates is critical to promoting long term occupant comfort, indoor air quality and building durability. The results of this study were expected to inform the residential building community on whether suppl...
Kerrigan, P. and Norton, P. National Renewable Energy Laboratory
Apr 27, 2016
7 Resources
0 Stars
Publicly accessible
7 Resources
0 Stars
Publicly accessible
Advancing Replicable Solutions for High-Performance Homes in the Southeast JMC Patrick Square
The work presented in this report advances the goals of the U.S. Department of Energy Building America program by improving the energy peformance of affordable and market-rate housing. Southface Energy Institute (Southface), part of the U.S. Department of Energy Building America r...
Sweet, M. et al Southface
Apr 27, 2016
3 Resources
0 Stars
Publicly accessible
3 Resources
0 Stars
Publicly accessible
Performance and Costs of Ductless Heat Pumps in Marine-Climate High-Performance Homes Habitat for Humanity The Woods
The Washington State University (WSU) Energy Program's Building America (BA) team conducted a case study of a high-performance affordable housing community: The Woods (Figure 1). This BA effort is part of a larger-scale study of 30 homes funded from 2013-2016 by Tacoma Public Util...
Lubliner, M. et al Washington State University
Apr 27, 2016
8 Resources
0 Stars
Publicly accessible
8 Resources
0 Stars
Publicly accessible
Mechanical Ventilation and Indoor Air Quality in Recently Constructed U.S. Homes in Marine and Cold-Dry Climates Data from Building America Project
Data were collected to characterize whole-house mechanical ventilation (WHMV) and indoor air quality (IAQ) in 55 homes in the Marine climate of Oregon and Cold-Dry climate of Colorado in the U.S. Sixteen homes were monitored for two weeks, with and without WHMV operating. Ventilat...
Zhao, H. et al Lawrence Berkeley National Laboratory
Mar 22, 2023
2 Resources
0 Stars
Publicly accessible
2 Resources
0 Stars
Publicly accessible
Brookfield Homes Passive House Performance Evaluation
TO4 3.1.3: Brookfield Homes Short-Term Results
TO5 3.1.3: Brookfield Passive House Monitoring
To further define its market position on high performance homebuilding, Brookfield worked with IBACOS and the Building America program to design and construct a Passive House (PH) certif...
Beach, R. et al Ibacos Innovation
Apr 27, 2016
4 Resources
0 Stars
Publicly accessible
4 Resources
0 Stars
Publicly accessible
Long-term occupancy data for residential and commercial building
Includes information about occupancy status (1 occupied; 0 unoccupied) of three rooms in a residential home and six commercial offices. The residential and commercial occupancy data files cover one month with at least a fifteen minute measurement time interval. Raw data are in C...
Dong, B. Lawrence Berkeley National Laboratory
Jul 24, 2015
2 Resources
0 Stars
In curation
2 Resources
0 Stars
In curation
Simplified Space Conditioning in Low-Load Homes
TO3 2.1.6: Simplified Space Conditioning
IBACOS anticipates that houses achieving 50% whole-house source energy savings with respect to the Building America 2010 Benchmark (Hendron and Engebrecht 2010a) will be considered "low load." Low load is defined by IBACOS as a house with ...
Poerschke, A. and Stecher, D. Ibacos Innovation
Apr 27, 2016
2 Resources
0 Stars
Publicly accessible
2 Resources
0 Stars
Publicly accessible
Solar Row Zero Energy Townhomes Boulder, CO
Wonderland Development has constructed a new "near zero energy" row home design in North Boulder consisting of 9 units: one 5-plex and two duplexes. NREL has performed short-term tests and installed long-term monitoring equipment in three of these units. Two of these units used a ...
Norton, P. et al National Renewable Energy Laboratory
Sep 27, 2016
11 Resources
0 Stars
Publicly accessible
11 Resources
0 Stars
Publicly accessible
Evaluation of Crawlspace Retrofits in Multifamily Buildings
In 2011 and early 2012, Building Science Corporation (BSC) collaborated with Innova Services Corporation on a multifamily community un-vented crawlspace retrofit project at Oakwood Gardens in Lansdale, Pennsylvania. BSC provided design consulting services and pre and post-retrofit...
Rudd, A. Advanced Building Systems
Apr 27, 2016
41 Resources
0 Stars
Publicly accessible
41 Resources
0 Stars
Publicly accessible
Comfort in High-Performance Homes in a Hot-Humid Climate
TO5 2.3.2: Large-Scale Temperature Study
Although space-conditioning systems are required to meet standards such as those in the Air Conditioning Contractors of America (ACCA) Manual RS (Rutkowski 1997) and the ASHRAE Standard 55 (ASHRAE 2013) comfort criteria, little is known ab...
Poerschke, A. and Beach, R. Ibacos Innovation
Apr 27, 2016
3 Resources
0 Stars
Publicly accessible
3 Resources
0 Stars
Publicly accessible
Weatherization Assistance Program
The U.S. Department of Energy's Weatherization Assistance Program (WAP) was created in 1976 to assist low-income families who lacked resources to invest in energy efficiency. WAP is operated in all 50 states, the District of Columbia, Native American tribes, and U.S. Territories. ...
Adams, R. and (EERE), O. Office of Energy Efficiency & Renewable Energy
Nov 25, 2014
1 Resources
0 Stars
In curation
1 Resources
0 Stars
In curation
Pilgrim Hot Springs Building Dimensions and Energy Modeling
This dataset was created to model the anticipated heating load of a geothermal project in development for the historical site of Pilgrim Hot Springs, and adds to the history of geothermal studies at the site. Models include an historical building (Nun's Quarters), existing modern ...
Garber-Slaght, R. and Coakley, M. National Renewable Energy Laboratory (NREL)
Feb 28, 2024
2 Resources
0 Stars
Curated
2 Resources
0 Stars
Curated
Measured Performance of a Varied Airflow Small-Diameter Duct System
In this study, researchers with the U.S. Department of Energy's Building America team IBACOS built on research previously done in two new-construction unoccupied test houses-one in Pittsburgh, Pennsylvania (Poerschke and Stecher 2014) and one in Fresno, California (Stecher and Poe...
Poerschke, A. Ibacos Innovation
Apr 27, 2016
5 Resources
0 Stars
Publicly accessible
5 Resources
0 Stars
Publicly accessible
National Hydropower Asset Assessment Program
The Oak Ridge National Laboratory (ORNL) National Hydropower Asset Assessment Program (NHAAP) is an integrated energy, water, and ecosystem research and geospatial data integration effort for efficient,
Webmaster, . and Laboratory, O. Oak Ridge National Laboratory
Nov 25, 2014
1 Resources
0 Stars
In curation
1 Resources
0 Stars
In curation
Occupant Behavior in Commercial Buildings: Synthetic Population, Co-Simulation with EnergyPlus and Agent Based Modeling
This technical manual serves as an outline of three separate research projects related to building energy performance modeling of occupant behavior, conducted at the Rutgers Center for Green Building (RCGB): a Synthetic Population project, a Co-Simulation of Synthetic Population w...
Andrews, C. National Renewable Energy Laboratory
Apr 26, 2016
1 Resources
0 Stars
In curation
1 Resources
0 Stars
In curation
U. S. Department of Energy's Compliance Certification Database
The Certification Database houses certification reports and compliance statements submitted by manufacturers for covered products and equipment subject to Federal conservation standards. The new database offers users an easy-to-use search function for existing records in an easily...
Armstrong, A. and (DOE), U. Office of Energy Efficiency & Renewable Energy
Nov 25, 2014
1 Resources
0 Stars
In curation
1 Resources
0 Stars
In curation
ResStock: Annual Baseline Results with Component Loads
The ResStock Analysis Tool was developed by NREL with support from the U.S. Department of Energy to provide a new approach to large-scale residential analysis by combining large public and private data sources, statistical sampling, detailed sub hourly building simulations, and hi...
Speake, A. et al National Renewable Energy Lab
Mar 03, 2023
6 Resources
0 Stars
Curated
6 Resources
0 Stars
Curated