Search OEDI Data
Showing results 1 - 5 of 5.
Show
results per page.
Order by:
Available Now:
Research Areas
Accessibility
Data Type
Organization
Source
Field Testing of an Unvented Roof with Fibrous Insulation, Tiles, and Vapor Diffusion Venting
BSC TO5 Task 2.5 Field Testing of an Un-vented Roof with Fibrous Insulation and Tiles Winter Park, FL 32789
Field test data available for wood moisture contents, temperature, and relative humidity.
Un-vented roofs (aka cathedral-ized attics) are an established presence in Florida...
Ueno, K. and Lstiburek, J. Building Science Corporation
Apr 27, 2016
2 Resources
0 Stars
Publicly accessible
2 Resources
0 Stars
Publicly accessible
Monitoring of Double-Stud Wall Moisture Conditions in the Northeast
BSC TO5 Task 2.2 Monitoring of Double Stud Wall Moisture Conditions in the Northeast
Field test data available for wood moisture contents, temperature, and relative humidity.
STRUCTURE House Devens, MA 01432
Three double-stud assemblies were compared: 12-in. ocSPF, 12-in. cellulo...
Ueno, K. Building Science Corporation
Apr 27, 2016
2 Resources
0 Stars
Publicly accessible
2 Resources
0 Stars
Publicly accessible
Evaluation of the U.S. Department of Energy Challenge Home Program Certification of Production Builders Chicago, IL and Devens, MA
TO4 Task 3.1 K Hovnanian Chicago, IL
DOE Challenge Home Program Certified
Home Constructed and Verified
Specifications
DOE Challenge Home
Building envelope
Ceiling R-49 blown fiberglass, Grade I
Walls 2x4 framing @ 16 o.c. with R-13 fiberglass batts, Grade I
and 1"" R-5 extrude...
Loomis, H. and Kerrigan, P. Building Science Corporation
Apr 27, 2016
6 Resources
0 Stars
Publicly accessible
6 Resources
0 Stars
Publicly accessible
Field Testing Unvented Roofs with Asphalt Shingles in Cold and Hot-humid Climates
BSC TO5 Task 7.1 Field Testing Unvented Roofs with Asphalt Shingles in Cold Climates Bolingbrook, IL 60440
BSC TO5 Task 7.1 Field Testing Unvented Roofs with Asphalt Shingles in Hot-Humid Climates Friendswood, TX 77546
To understand the long-term moisture performance of unvented ...
Ueno, K. and Lstiburek, J. Building Science Corporation
Apr 27, 2016
3 Resources
0 Stars
Publicly accessible
3 Resources
0 Stars
Publicly accessible
Analysis of Joist Masonry Moisture Content Monitoring
BSC TO5 Task 7.2 Analysis of Joist Masonry Moisture Content Monitoring
House Lawrence, MA 01840
This work involved the field monitoring of embedded wood joist ends in a solid brick building in zone 5A that was retrofitted with interior insulation. Eleven joists throughout the bui...
Ueno, K. Building Science Corporation
Apr 27, 2016
3 Resources
0 Stars
Publicly accessible
3 Resources
0 Stars
Publicly accessible