Raleigh Housing Authority Duct Sealing Evaluation
In multifamily and attached buildings, manual duct sealing methods are often impractical or very costly and disruptive because of the difficulty in accessing leakage sites. In this project, two retrofit duct sealing techniques manually applied sealants and injecting a spray sealan...
Dentz, J. et al The Levy Partnership, Inc Systems Building Research Alliance
Apr 27, 2016
18 Resources
0 Stars
Publicly accessible
18 Resources
0 Stars
Publicly accessible
Public Housing: A Tailored Approach to Energy Retrofits Raleigh
More than 1 million U.S. Department of Housing and Urban Development-supported public housing units provide rental housing for eligible low-income families across the country. These units range from scattered single-family houses to high-rise apartments. In this project, the Advan...
Dentz, J. et al The Levy Partnership, Inc Systems Building Research Alliance
Apr 27, 2016
7 Resources
0 Stars
Publicly accessible
7 Resources
0 Stars
Publicly accessible
SWA_Challenges_MF_ESMFNC_ZERH
This study completed by Steven Winter Associates documents the challenge that exist for existing multi family buildings to achieve Energy Star for new homes or Zero Energy Ready Home Certification.
Cindrich. . et al National Renewable Energy Laboratory
Jul 28, 2023
1 Resources
0 Stars
Publicly accessible
1 Resources
0 Stars
Publicly accessible
Greenbelt Homes Pilot Program: Summary of Building Envelope Retrofits, Planned HVAC Equipment Upgrades, and Energy Savings
In fall 2010, Greenbelt Homes, Inc. (GHI) a 1,566-home cooperative of circa 1930-1940 homes in Greenbelt, Maryland, undertook a multiyear pilot energy efficiency retrofit project. GHI established this pilot project as a basis for decision making for the rollout of a decade-long co...
Mallay, D. et al Home Innovation Research Labs National Association of Home Builders
Jul 21, 2016
4 Resources
0 Stars
Publicly accessible
4 Resources
0 Stars
Publicly accessible
Evaluation of the U.S. Department of Energy Challenge Home Program Certification of Production Builders Chicago, IL and Devens, MA
TO4 Task 3.1 K Hovnanian Chicago, IL
DOE Challenge Home Program Certified
Home Constructed and Verified
Specifications
DOE Challenge Home
Building envelope
Ceiling R-49 blown fiberglass, Grade I
Walls 2x4 framing @ 16 o.c. with R-13 fiberglass batts, Grade I
and 1"" R-5 extrude...
Loomis, H. and Kerrigan, P. Building Science Corporation
Apr 27, 2016
6 Resources
0 Stars
Publicly accessible
6 Resources
0 Stars
Publicly accessible
Analysis of Pre-Retrofit Building and Utility Data Southeast United States
TO4 9.1.2: Comm. Scale Military Housing Upgrades
This project delves into the workflow and results of regression models on monthly and daily utility data (meter readings of electricity consumption), outlining a process for screening and gathering useful results from inverse model...
Beach, R. and Prahl, D. Ibacos Innovation
Apr 27, 2016
12 Resources
0 Stars
In curation
12 Resources
0 Stars
In curation
Field Testing Unvented Roofs with Asphalt Shingles in Cold and Hot-humid Climates
BSC TO5 Task 7.1 Field Testing Unvented Roofs with Asphalt Shingles in Cold Climates Bolingbrook, IL 60440
BSC TO5 Task 7.1 Field Testing Unvented Roofs with Asphalt Shingles in Hot-Humid Climates Friendswood, TX 77546
To understand the long-term moisture performance of unvented ...
Ueno, K. and Lstiburek, J. Building Science Corporation
Apr 27, 2016
3 Resources
0 Stars
Publicly accessible
3 Resources
0 Stars
Publicly accessible
Comfort in High-Performance Homes in a Hot-Humid Climate
TO5 2.3.2: Large-Scale Temperature Study
Although space-conditioning systems are required to meet standards such as those in the Air Conditioning Contractors of America (ACCA) Manual RS (Rutkowski 1997) and the ASHRAE Standard 55 (ASHRAE 2013) comfort criteria, little is known ab...
Poerschke, A. and Beach, R. Ibacos Innovation
Apr 27, 2016
3 Resources
0 Stars
Publicly accessible
3 Resources
0 Stars
Publicly accessible
Monitoring of Double-Stud Wall Moisture Conditions in the Northeast
BSC TO5 Task 2.2 Monitoring of Double Stud Wall Moisture Conditions in the Northeast
Field test data available for wood moisture contents, temperature, and relative humidity.
STRUCTURE House Devens, MA 01432
Three double-stud assemblies were compared: 12-in. ocSPF, 12-in. cellulo...
Ueno, K. Building Science Corporation
Apr 27, 2016
2 Resources
0 Stars
Publicly accessible
2 Resources
0 Stars
Publicly accessible
Commercial and Residential Hourly Load Profiles for all TMY3 Locations in the United States
Note: This dataset has been superseded by the dataset found at "End-Use Load Profiles for the U.S. Building Stock" (submission 4520; linked in the submission resources), which is a comprehensive and validated representation of hourly load profiles in the U.S. commercial and reside...
Ong, S. and Clark, N. National Renewable Energy Laboratory
Nov 25, 2014
22 Resources
1 Stars
Publicly accessible
22 Resources
1 Stars
Publicly accessible
Moisture Risk in Unvented Attics Due to Air Leakage Paths Minneapolis Minnesota
IBACOS completed an initial analysis of moisture damage potential in an unvented attic insulated with closed-cell spray polyurethane foam. To complete this analysis, the research team collected field data, used computational fluid dynamics to quantify the airflow rates through ind...
Rapport, A. et al Ibacos Innovation
Apr 27, 2016
6 Resources
0 Stars
Publicly accessible
6 Resources
0 Stars
Publicly accessible
Achieving Challenge Home in Affordable Housing in the Hot Humid Climate
The Building America Partnership for Improved Residential Construction (BA-PIRC), one of the Building America research team leads, has partnered with two builders as they work through the Challenge Home certification process in one test home each. The builder partners participatin...
Beal, D. et al University of Central Florida Florida Solar Energy Center
Apr 27, 2016
9 Resources
0 Stars
Publicly accessible
9 Resources
0 Stars
Publicly accessible
Community-Scale Attic Retrofit and Home Energy Upgrade Data Mining Hot Dry Climate
Retrofitting is an essential element of any comprehensive strategy for improving residential energy efficiency. The residential retrofit market is still developing, and program managers must develop innovative strategies to increase uptake and promote economies of scale. Residenti...
Jackson, J. et al Davis Energy
Apr 27, 2016
46 Resources
0 Stars
Publicly accessible
46 Resources
0 Stars
Publicly accessible
Retrofitting a 1960s Split-Level Cold-Climate Home
The U.S. Department of Energy Building America research team Consortium for Advanced Residential Buildings (CARB) partnered with Preferred Builders, a previous CARB partner and builder of the Performance House (DOE 2013) and the owners of a 1960s split-level home in Westport, Conn...
Puttagunta, S. Steven Winter Associates of the Consortium for Advanced Residential Buildings
Apr 27, 2016
3 Resources
0 Stars
Publicly accessible
3 Resources
0 Stars
Publicly accessible
Solar Row Zero Energy Townhomes Boulder, CO
Wonderland Development has constructed a new "near zero energy" row home design in North Boulder consisting of 9 units: one 5-plex and two duplexes. NREL has performed short-term tests and installed long-term monitoring equipment in three of these units. Two of these units used a ...
Norton, P. et al National Renewable Energy Laboratory
Sep 27, 2016
11 Resources
0 Stars
Publicly accessible
11 Resources
0 Stars
Publicly accessible
Greenbuilt Construction Energy Efficiency Retrofit House Demonstration Sacramento
One of the homes that was part of Sacramento Municipal Utility District's (SMUD) Energy Efficiency Retrofit Demonstration (EERD) project was a 1980's era home in Fair Oaks, California, referred to as the Greenbuilt house, as Greenbuilt Construction completed the retrofit of the h...
Sparn, B. et al Mountain Energy Partnership
Aug 27, 2018
8 Resources
0 Stars
Publicly accessible
8 Resources
0 Stars
Publicly accessible
Phased Retrofits in Existing Homes in Florida Phase I: Shallow and Deep Retrofits
The U.S. Department of Energy's Building America research team Building America Partnership for Improved Residential Construction is collaborating with Florida Power & Light (FPL) to conduct a phased residential energy-efficiency retrofit program. This research seeks to establish ...
Beal, D. et al University of Central Florida Florida Solar Energy Center
Apr 27, 2016
10 Resources
0 Stars
Publicly accessible
10 Resources
0 Stars
Publicly accessible
Measured Performance of a Varied Airflow Small-Diameter Duct System
In this study, researchers with the U.S. Department of Energy's Building America team IBACOS built on research previously done in two new-construction unoccupied test houses-one in Pittsburgh, Pennsylvania (Poerschke and Stecher 2014) and one in Fresno, California (Stecher and Poe...
Poerschke, A. Ibacos Innovation
Apr 27, 2016
5 Resources
0 Stars
Publicly accessible
5 Resources
0 Stars
Publicly accessible
TP84227_FS83049_OPData
The data set represents the data used for the analysis of operational carbon emissions for a carbon case study of a typical production builder's home in two common climate zones, Climate Zone 2 (Warm) and CZ 5 (Cold). A data set for embodied carbon emissions analysis for the sam...
RapportBuilding Technologies and Science Center
Jan 17, 2023
1 Resources
0 Stars
Publicly accessible
1 Resources
0 Stars
Publicly accessible
TP84227_FS83049_ECData
The data set represents the data used for the analysis of embodied carbon emissions for a carbon case study of a typical production builder's home in two common climate zones, Climate Zone 2 (Warm) and CZ 5 (Cold). A data set for operational carbon emissions analysis for the same...
RapportBuilding Technologies and Science Center
Jan 17, 2023
1 Resources
0 Stars
Publicly accessible
1 Resources
0 Stars
Publicly accessible
Approaches to 30% Energy Savings at the Community Scale in the Hot-Humid Climate
The Building America Partnership for Improved Residential Construction, formerly the Building America Industrialized Housing Partnership, has worked with several community-scale builders within the hot-humid climate zone to improve performance of production-, or community-scale, h...
Beal, D. et al University of Central Florida Florida Solar Energy Center
Apr 27, 2016
9 Resources
0 Stars
Publicly accessible
9 Resources
0 Stars
Publicly accessible
Sacramento Deep Energy Retrofit (DER) Home Study
This project was part of the Sacramento Municipal Utility District (SMUD) Deep Energy Retrofit (DER) Project which included several other homes in addition to the the subject of this study. Some of the reports and presentations included in this dataset cover the whole DER project....
Keesee, M. Sacramento Municipal Utility District
Aug 10, 2016
8 Resources
0 Stars
Publicly accessible
8 Resources
0 Stars
Publicly accessible
Mechanical Ventilation and Indoor Air Quality in Recently Constructed U.S. Homes in Marine and Cold-Dry Climates Data from Building America Project
Data were collected to characterize whole-house mechanical ventilation (WHMV) and indoor air quality (IAQ) in 55 homes in the Marine climate of Oregon and Cold-Dry climate of Colorado in the U.S. Sixteen homes were monitored for two weeks, with and without WHMV operating. Ventilat...
Zhao, H. et al Lawrence Berkeley National Laboratory
Mar 22, 2023
2 Resources
0 Stars
Publicly accessible
2 Resources
0 Stars
Publicly accessible
Long-term occupancy data for residential and commercial building
Includes information about occupancy status (1 occupied; 0 unoccupied) of three rooms in a residential home and six commercial offices. The residential and commercial occupancy data files cover one month with at least a fifteen minute measurement time interval. Raw data are in C...
Dong, B. Lawrence Berkeley National Laboratory
Jul 24, 2015
2 Resources
0 Stars
In curation
2 Resources
0 Stars
In curation
Field Testing of Compartmentalization Methods for Multifamily Construction Washington DC
BSC TO5 Task 2.1 Field Testing of Compartmentalization Methods for Multifamily Construction Capitol Heights, MD 20743
A building comprising five vertical townhome units was built in the Washington, D.C., area; the townhomes were three-story slab-on-grade units (1700-2000 ft2) wit...
Ueno, K. and Lstiburek, J. Building Science Corporation
Apr 27, 2016
22 Resources
0 Stars
Publicly accessible
22 Resources
0 Stars
Publicly accessible