Search OEDI Data
Showing results 26 - 50 of 451.
Show
results per page.
Order by:
Available Now:
Research Areas
Accessibility
Data Type
Organization
Source
Structural Inventory of Great Basin Geothermal Systems and Definition of Favorable Structural Settings
Structural controls of 426 geothermal systems in the Great Basin region including western Nevada, central Nevada, northwestern Nevada, northeastern Nevada, east-central Nevada, eastern California, southern Oregon, and western Utah were analyzed with literature research, air photos...
Faulds, J. University of Nevada
Dec 31, 2013
1 Resources
0 Stars
Publicly accessible
1 Resources
0 Stars
Publicly accessible
Slip and Dilation Tendency Analysis of McGinness Hills Geothermal Area
Slip and Dilation Tendency in focus areas
Critically stressed fault segments have a relatively high likelihood of acting as fluid flow conduits (Sibson, 1994). As such, the tendency of a fault segment to slip (slip tendency; Ts; Morris et al., 1996) or to dilate (dilation tendency...
E., J. University of Nevada
Dec 31, 2013
1 Resources
0 Stars
Publicly accessible
1 Resources
0 Stars
Publicly accessible
Utah FORGE: Mineral Mountains West Fault System Report
This archive contains a report on the Mineral Mountains West fault system as part of phase 2C and the evidence for the northern terminus of this structure. Geologic field mapping, reprocessing of 3D seismic reflection data, and soil gas surveys contributed to this effort.
Simmons, S. and Miller, J. Energy and Geoscience Institute at the University of Utah
Jul 01, 2019
1 Resources
0 Stars
Publicly accessible
1 Resources
0 Stars
Publicly accessible
3D Model of the Tuscarora Geothermal Area
The Tuscarora geothermal system sits within a ~15 km wide left-step in a major west-dipping range-bounding normal fault system. The step over is defined by the Independence Mountains fault zone and the Bull Runs Mountains fault zone which overlap along strike. Strain is transferre...
E., J. University of Nevada
Dec 31, 2013
1 Resources
0 Stars
Publicly accessible
1 Resources
0 Stars
Publicly accessible
Oregon Cascades Play Fairway Analysis: Faults and Heat Flow Maps
This submission includes a fault map of the Oregon Cascades and backarc, a probability map of heat flow, and a fault density probability layer. More extensive metadata can be found within each zip file.
For information about "Oregon Faults," contact John David Trimble, Oregon Sta...
Trimble, J. University of Utah
Nov 15, 2015
4 Resources
0 Stars
Publicly accessible
4 Resources
0 Stars
Publicly accessible
Slip and Dilation Tendency Analysis of the Salt Wells Geothermal Area
Critically stressed fault segments have a relatively high likelihood of acting as fluid flow conduits (Sibson, 1994). As such, the tendency of a fault segment to slip (slip tendency; Ts; Morris et al., 1996) or to dilate (dilation tendency; Td; Ferrill et al., 1999) provides an in...
E., J. University of Nevada
Dec 31, 2013
1 Resources
0 Stars
Publicly accessible
1 Resources
0 Stars
Publicly accessible
Gearbox Fault Diagnosis Data
Gearbox Fault Diagnosis Data set include the vibration dataset recorded by using SpectraQuest’s Gearbox Fault Diagnostics Simulator.
Dataset has been recorded with the help of 4 vibration sensors placed in four different direction.
Data set has been recorded under variation of...
Pandya, Y. National Renewable Energy Laboratory
Jun 02, 2018
1 Resources
0 Stars
In curation
1 Resources
0 Stars
In curation
Structural Controls of the Neal Hot Springs Geothermal System, Eastern Oregon
Detailed geologic mapping (1:24,000 scale), structural and geochemical analyses, and integration of available geophysical and well-field data were utilized to assess the structural controls of the Neal Hot Springs geothermal field in eastern Oregon. The geothermal field lies withi...
Edwards, J. and Faulds, J. University of Nevada
May 31, 2013
1 Resources
0 Stars
Publicly accessible
1 Resources
0 Stars
Publicly accessible
Data Sets for Evaluation of Building Fault Detection and Diagnostics Algorithms
This documentation and dataset can be used to test the performance of automated fault detection and diagnostics algorithms for buildings. The dataset was created by LBNL, PNNL, NREL, ORNL and ASHRAE RP-1312 (Drexel University). It includes data for air-handling units and rooftop u...
Lin, G. and Mitchell, R. Lawrence Berkeley National Laboratory
Feb 26, 2019
2 Resources
0 Stars
Publicly accessible
2 Resources
0 Stars
Publicly accessible
Hawaii Play Fairway Analysis: USGS Quaternary Fault and Fold Database
This database contains information on faults and associated folds in the United States that are believed to be sources of M>6 earthquakes during the Quaternary (the past 1,600,000 years). Maps of these geologic structures are linked to detailed descriptions and references. Used t...
Lautze, N. University of Hawaii
Jan 01, 2015
1 Resources
0 Stars
Publicly accessible
1 Resources
0 Stars
Publicly accessible
Slip and Dilation Tendency Analysis of the Patua Geothermal Area
Critically stressed fault segments have a relatively high likelihood of acting as fluid flow conduits (Sibson, 1994). As such, the tendency of a fault segment to slip or to dilate provides an indication of which faults or fault segments within a geothermal system are critically st...
E., J. University of Nevada
Dec 31, 2013
1 Resources
0 Stars
Publicly accessible
1 Resources
0 Stars
Publicly accessible
LBNL Fault Detection and Diagnostics Datasets
These datasets can be used to evaluate and benchmark the performance accuracy of Fault Detection and Diagnostics (FDD) algorithms or tools. It contains operational data from simulation, laboratory experiments, and field measurements from real buildings for seven HVAC systems/equip...
Granderson, J. et al Lawrence Berkeley National Laboratory
Aug 01, 2022
5 Resources
0 Stars
Publicly accessible
5 Resources
0 Stars
Publicly accessible
Oregon Cascades Play Fairway Analysis: Maps
The maps in this submission include: heat flow, alkalinity, Cl, Mg, SiO2, Quaternary volcanic rocks, faults, and land ownership. All of the Oregon Cascade region. The work was done by John Trimble, in 2015, at Oregon State University.
Trimble, J. University of Utah
Dec 15, 2015
9 Resources
0 Stars
Publicly accessible
9 Resources
0 Stars
Publicly accessible
Processed Lab Data for Neural Network-Based Shear Stress Level Prediction
Machine learning can be used to predict fault properties such as shear stress, friction, and time to failure using continuous records of fault zone acoustic emissions. The files are extracted features and labels from lab data (experiment p4679). The features are extracted with a n...
Marone, C. et al Pennsylvania State University
May 14, 2021
3 Resources
0 Stars
Publicly accessible
3 Resources
0 Stars
Publicly accessible
Hot Pot Fault Summary
Compilation of faults interpreted from seismic reflection survey and from field observations.
Lane, M. Oski Energy LLC
Jun 28, 2013
2 Resources
0 Stars
Publicly accessible
2 Resources
0 Stars
Publicly accessible
Geothermal Exploration Raster Files for Utah Play Fairway Analysis
This submission contains raster files associated with several datasets that include earthquake density, Na/K geothermometers, fault density, heat flow, and gravity. Integrated together using spatial modeler tools in ArcGIS, these files can be used for play fairway analysis in rega...
Wannamaker, P. Energy and Geoscience Institute at the University of Utah
Jun 16, 2017
5 Resources
0 Stars
Publicly accessible
5 Resources
0 Stars
Publicly accessible
A Conceptual Geologic Model for the Newberry Volcano EGS Site in Central Oregon: Constraining Heat Capacity and Permeability through Interpretation of Multicomponent Geosystems Data
Newberry Volcano, a voluminous (500 km3) basaltic/andesitic/rhyolitic shield volcano located near the intersection of the Cascade volcanic arc, the Oregon High Lava Plains and Brothers Fault Zone, and the northern Basin and Range Province, has been the site of geothermal explorati...
Mark-Moser, M. et al National Energy Technology Laboratory
Feb 22, 2016
1 Resources
0 Stars
Publicly accessible
1 Resources
0 Stars
Publicly accessible
Nevada Great Basin Play Fairway Analysis Regional Data
This project focused on defining geothermal play fairways and development of a detailed geothermal potential map of a large transect across the Great Basin region (96,000 km2), with the primary objective of facilitating discovery of commercial-grade, blind geothermal fields (i.e. ...
Faulds, J. Nevada Bureau of Mines and Geology
Oct 28, 2015
47 Resources
0 Stars
Publicly accessible
47 Resources
0 Stars
Publicly accessible
Shallow (2-meter) Temperature Surveys in Colorado
Shallow temperature surveys are useful in early-stage geothermal exploration to delineate surface outflow zones, with the intent to identify the source of upwelling, usually a fault. Detailed descriptions of the 2-meter survey method and equipment design can be found in Coolbaugh ...
E., R. Flint Geothermal, LLC
Feb 01, 2012
1 Resources
0 Stars
Publicly accessible
1 Resources
0 Stars
Publicly accessible
Washington Play Fairway Analysis Geothermal Heat and Permeability Potential Geodatabases
This file contains file geodatabases of the Mount St. Helens seismic zone (MSHSZ), Wind River valley (WRV) and Mount Baker (MB) geothermal play-fairway sites in the Washington Cascades. The geodatabases include input data (feature classes) and output rasters (generated from modeli...
Norman, D. et al Washington Division of Geology and Earth Resources
Dec 15, 2015
5 Resources
0 Stars
Publicly accessible
5 Resources
0 Stars
Publicly accessible
3D Model of the Neal Hot Springs Geothermal Area
The Neal Hot Springs geothermal system lies in a left-step in a north-striking, west-dipping normal fault system, consisting of the Neal Fault to the south and the Sugarloaf Butte Fault to the north (Edwards, 2013). The Neal Hot Springs 3D geologic model consists of 104 faults and...
E., J. University of Nevada
Dec 31, 2013
1 Resources
0 Stars
Publicly accessible
1 Resources
0 Stars
Publicly accessible
Utah FORGE: Nevada Crustal Strain
An estimate of the total magnitude of crustal strain in Nevada (2nd invariant of the strain rate), independent of fault orientation. Crustal strain based on GPS station measurements. Nevada Bureau of Mines and Geology.
Blewitt, G. et al Energy and Geoscience Institute at the University of Utah
Oct 01, 2004
2 Resources
0 Stars
Publicly accessible
2 Resources
0 Stars
Publicly accessible
West Flank Coso FORGE: ArcGIS Data for Geologic Model
Archive of ArcGIS data from the West Flank FORGE site located in Coso, California. Archive contains the following eight shapefiles:
Polygon of the 3D geologic model (WestFlank3DGeologicModelExtent)
Polylines of the traces 3D modeled faults (WestFlank3DModeledFaultTraces)
Polyline...
Sandia National Laboratories
Mar 01, 2016
2 Resources
0 Stars
Publicly accessible
2 Resources
0 Stars
Publicly accessible
ORNL Air Handling Fault Test Data Yarnell Station Research House
ORNL test data for air handling faults. Data contains electrical measurements and power consumption measurements.
Fugate, D. and Laboratory, O. Oak Ridge National Laboratory
Mar 22, 2017
5 Resources
0 Stars
In curation
5 Resources
0 Stars
In curation
Hawthorne Nevada Deep Direct-Use Feasibility Study Geology
The objective of this project is to use a multi-disciplinary, three-tiered approach to assess the geothermal resource and determine the feasibility of implementing a large-scale, direct-use facility for the Hawthorne Army Depot (HAD) and the various town and county facilities in H...
Lowry, T. and Oldow, J. Nevada Bureau of Mines and Geology
Mar 29, 2018
5 Resources
0 Stars
Publicly accessible
5 Resources
0 Stars
Publicly accessible