Search OEDI Data
Showing results 26 - 50 of 57.
Show
results per page.
Order by:
Available Now:
Research Areas
Accessibility
Data Type
Organization
Source
Thermostatic Radiator Valve Evaluation and Demonstration
A large stock of multifamily buildings in the Northeast and Midwest uses hot water or steam for space heating. Typically, residents do not pay for heat directly (i.e., heating fuel serves a central plant and use is not submetered). Losses from these systems are typically high, and...
Dentz, J. and Ansanelli, E. The Levy Partnership, Inc Systems Building Research Alliance
Apr 27, 2016
2 Resources
0 Stars
Publicly accessible
2 Resources
0 Stars
Publicly accessible
Comparative Performance of Four Prototype Mechanical Building Cooling Systems in a Desert Climate
Data and result of approximately fifteen months of monitoring of four houses located in the desert climate of Borrego Springs, California. Four houses were constructed using identical floor plans but differing wall materials, and different cooling systems that were designed to red...
Springer, D. et al Davis Energy
Jul 20, 2016
9 Resources
0 Stars
Curated
9 Resources
0 Stars
Curated
Solar Row Zero Energy Townhomes Boulder, CO
Wonderland Development has constructed a new "near zero energy" row home design in North Boulder consisting of 9 units: one 5-plex and two duplexes. NREL has performed short-term tests and installed long-term monitoring equipment in three of these units. Two of these units used a ...
Norton, P. et al National Renewable Energy Laboratory
Sep 27, 2016
11 Resources
0 Stars
Publicly accessible
11 Resources
0 Stars
Publicly accessible
Mass Customization of Prefabricated Panel Blocks for Deep Wall Insulation Retrofits
The project this data comes from looks to make building wall retrofits less expensive and easier to install by using exterior insulating panels. This is done to make buildings more energy efficient without expensive wall retrofits or reconstruction. The "Measurement and Verificati...
Sharon, A. et al Fraunhofer Center for Manufacturing Innovation CMI
Dec 14, 2021
2 Resources
0 Stars
Publicly accessible
2 Resources
0 Stars
Publicly accessible
Multifamily Programmable Thermostat Data
This data set, compiled by the Fraunhofer Center for Sustainable Energy Systems, includes long-term 10-minute temperature and relative humidity data, and HVAC system state data for 79 apartments in a low-income housing complex in Revere, MA. The monitoring period spans two winters...
Urban, B. et al Fraunhofer USA
Jul 27, 2015
2 Resources
0 Stars
Publicly accessible
2 Resources
0 Stars
Publicly accessible
Phased Retrofits in Existing Homes in Florida Phase I: Shallow and Deep Retrofits
The U.S. Department of Energy's Building America research team Building America Partnership for Improved Residential Construction is collaborating with Florida Power & Light (FPL) to conduct a phased residential energy-efficiency retrofit program. This research seeks to establish ...
Beal, D. et al University of Central Florida Florida Solar Energy Center
Apr 27, 2016
10 Resources
0 Stars
Publicly accessible
10 Resources
0 Stars
Publicly accessible
Simplified Space Conditioning in Low-Load Homes
TO3 2.1.6: Simplified Space Conditioning
IBACOS anticipates that houses achieving 50% whole-house source energy savings with respect to the Building America 2010 Benchmark (Hendron and Engebrecht 2010a) will be considered "low load." Low load is defined by IBACOS as a house with ...
Poerschke, A. and Stecher, D. Ibacos Innovation
Apr 27, 2016
2 Resources
0 Stars
Publicly accessible
2 Resources
0 Stars
Publicly accessible
Mechanical Ventilation and Indoor Air Quality in Recently Constructed U.S. Homes in Marine and Cold-Dry Climates Data from Building America Project
Data were collected to characterize whole-house mechanical ventilation (WHMV) and indoor air quality (IAQ) in 55 homes in the Marine climate of Oregon and Cold-Dry climate of Colorado in the U.S. Sixteen homes were monitored for two weeks, with and without WHMV operating. Ventilat...
Zhao, H. et al Lawrence Berkeley National Laboratory
Mar 22, 2023
2 Resources
0 Stars
Publicly accessible
2 Resources
0 Stars
Publicly accessible
Evaluation of the Performance of Houses With and Without Supplemental Dehumidification in a Hot-Humid Climate
Understanding indoor humidity conditions in low energy homes in hot-humid climates is critical to promoting long term occupant comfort, indoor air quality and building durability. The results of this study were expected to inform the residential building community on whether suppl...
Kerrigan, P. and Norton, P. National Renewable Energy Laboratory
Apr 27, 2016
7 Resources
0 Stars
Publicly accessible
7 Resources
0 Stars
Publicly accessible
LBNL Fault Detection and Diagnostics Datasets
These datasets can be used to evaluate and benchmark the performance accuracy of Fault Detection and Diagnostics (FDD) algorithms or tools. It contains operational data from simulation, laboratory experiments, and field measurements from real buildings for seven HVAC systems/equip...
Granderson, J. et al Lawrence Berkeley National Laboratory
Aug 01, 2022
5 Resources
0 Stars
Publicly accessible
5 Resources
0 Stars
Publicly accessible
Advancing Replicable Solutions for High-Performance Homes in the Southeast JMC Patrick Square
The work presented in this report advances the goals of the U.S. Department of Energy Building America program by improving the energy peformance of affordable and market-rate housing. Southface Energy Institute (Southface), part of the U.S. Department of Energy Building America r...
Sweet, M. et al Southface
Apr 27, 2016
3 Resources
0 Stars
Publicly accessible
3 Resources
0 Stars
Publicly accessible
Commercial Reference Building: Midrise Apartment
Commercial reference buildings provide complete descriptions for whole building energy analysis using EnergyPlus (see "About EnergyPlus" resource link) simulation software. Included here is data pertaining to the reference building type "Midrise Apartment" for each of the 16 clima...
Deru, M. et al National Renewable Energy Laboratory
Nov 25, 2014
7 Resources
0 Stars
In curation
7 Resources
0 Stars
In curation
Commercial Reference Building: Primary School
Commercial reference buildings provide complete descriptions for whole building energy analysis using EnergyPlus (see "About EnergyPlus" resource link) simulation software. Included here is data pertaining to the reference building type "Primary School" for each of the 16 climate ...
Deru, M. et al National Renewable Energy Laboratory
Nov 25, 2014
7 Resources
0 Stars
In curation
7 Resources
0 Stars
In curation
Commercial Reference Building: Quick Service Restaurant
Commercial reference buildings provide complete descriptions for whole building energy analysis using EnergyPlus (see "About EnergyPlus" resource link) simulation software. Included here is data pertaining to the reference building type "Quick Service Restaurant" for each of the 1...
Deru, M. et al National Renewable Energy Laboratory
Nov 25, 2014
7 Resources
0 Stars
In curation
7 Resources
0 Stars
In curation
Commercial Reference Building: Secondary School
Commercial reference buildings provide complete descriptions for whole building energy analysis using EnergyPlus (see "About EnergyPlus" resource link) simulation software. Included here is data pertaining to the reference building type "Secondary School" for each of the 16 climat...
Deru, M. et al National Renewable Energy Laboratory
Nov 25, 2014
7 Resources
0 Stars
In curation
7 Resources
0 Stars
In curation
Commercial Reference Building: Small Hotel
Commercial reference buildings provide complete descriptions for whole building energy analysis using EnergyPlus (see "About EnergyPlus" resource link) simulation software. Included here is data pertaining to the reference building type "Small Hotel" for each of the 16 climate zon...
Deru, M. et al National Renewable Energy Laboratory
Nov 25, 2014
7 Resources
0 Stars
In curation
7 Resources
0 Stars
In curation
Commercial Reference Building: Small Office
Commercial reference buildings provide complete descriptions for whole building energy analysis using EnergyPlus (see "About EnergyPlus" resource link) simulation software. Included here is data pertaining to the reference building type "Small Office" for each of the 16 climate zo...
Deru, M. et al National Renewable Energy Laboratory
Nov 25, 2014
7 Resources
0 Stars
In curation
7 Resources
0 Stars
In curation
Commercial Reference Building: Strip Mall
Commercial reference buildings provide complete descriptions for whole building energy analysis using EnergyPlus (see "About EnergyPlus" resource link) simulation software. Included here is data pertaining to the reference building type "Strip Mall" for each of the 16 climate zone...
Deru, M. et al National Renewable Energy Laboratory
Nov 25, 2014
7 Resources
0 Stars
In curation
7 Resources
0 Stars
In curation
Commercial Reference Building: Supermarket
Commercial reference buildings provide complete descriptions for whole building energy analysis using EnergyPlus (see "About EnergyPlus" resource link) simulation software. Included here is data pertaining to the reference building type "Supermarket" for each of the 16 climate zon...
Deru, M. et al National Renewable Energy Laboratory
Nov 25, 2014
7 Resources
0 Stars
In curation
7 Resources
0 Stars
In curation
Commercial Reference Building: Warehouse
Commercial reference buildings provide complete descriptions for whole building energy analysis using EnergyPlus (see "About EnergyPlus" resource link) simulation software. Included here is data pertaining to the reference building type "Warehouse" for each of the 16 climate zones...
Deru, M. et al National Renewable Energy Laboratory
Nov 25, 2014
7 Resources
0 Stars
In curation
7 Resources
0 Stars
In curation
Monitoring of Double-Stud Wall Moisture Conditions in the Northeast
BSC TO5 Task 2.2 Monitoring of Double Stud Wall Moisture Conditions in the Northeast
Field test data available for wood moisture contents, temperature, and relative humidity.
STRUCTURE House Devens, MA 01432
Three double-stud assemblies were compared: 12-in. ocSPF, 12-in. cellulo...
Ueno, K. Building Science Corporation
Apr 27, 2016
2 Resources
0 Stars
Publicly accessible
2 Resources
0 Stars
Publicly accessible
Analysis of Joist Masonry Moisture Content Monitoring
BSC TO5 Task 7.2 Analysis of Joist Masonry Moisture Content Monitoring
House Lawrence, MA 01840
This work involved the field monitoring of embedded wood joist ends in a solid brick building in zone 5A that was retrofitted with interior insulation. Eleven joists throughout the bui...
Ueno, K. Building Science Corporation
Apr 27, 2016
3 Resources
0 Stars
Publicly accessible
3 Resources
0 Stars
Publicly accessible
Commercial Reference Building: Full Service Restaurant
Commercial reference buildings provide complete descriptions for whole building energy analysis using EnergyPlus (see "About EnergyPlus" resource link) simulation software. Included here is data pertaining to the reference building type "Full Service Restaurant" for each of the 16...
Deru, M. et al National Renewable Energy Laboratory
Nov 25, 2014
7 Resources
0 Stars
In curation
7 Resources
0 Stars
In curation
Commercial Reference Building: Hospital
Commercial reference buildings provide complete descriptions for whole building energy analysis using EnergyPlus (see "About EnergyPlus" resource link) simulation software. Included here is data pertaining to the reference building type "Hospital" for each of the 16 climate zones ...
Deru, M. et al National Renewable Energy Laboratory
Nov 25, 2014
7 Resources
0 Stars
In curation
7 Resources
0 Stars
In curation
Commercial Reference Building: Large Hotel
Commercial reference buildings provide complete descriptions for whole building energy analysis using EnergyPlus (see "About EnergyPlus" resource link) simulation software. Included here is data pertaining to the reference building type "Large Hotel" for each of the 16 climate zon...
Deru, M. et al National Renewable Energy Laboratory
Nov 25, 2014
7 Resources
0 Stars
In curation
7 Resources
0 Stars
In curation