Search OEDI Data
Showing results 126 - 131 of 131.
Show
results per page.
Order by:
Available Now:
Research Areas
Accessibility
Data Type
Organization
Source
Geogenic Helium Release from Rock Fracture
In this project 38 uniaxial compaction tests were conducted at Sandia National Laboratories with 7 different rock types. During these tests, we created a vacuum system and evacuated and measured all the helium that was released by the samples during crushing. The experimental file...
Kibikas, W. Sandia National Laboratories
Jan 24, 2025
3 Resources
0 Stars
Publicly accessible
3 Resources
0 Stars
Publicly accessible
High-Pressure Combustion and Deflagration-to-Detonation Transition in Ethylene/Nitrous Oxide Mixtures
In this paper, the combustion of nitrous oxide with a simple hydrocarbon, ethylene, at high initial pressures is investigated. A series of experiments were conducted using a stoichiometric C2H4-N2O mixture in a round, smooth-walled tube with initial pressures of 125 to 337 psi. ...
Grubelich, M. Sandia National Laboratories
Nov 01, 2013
1 Resources
0 Stars
Publicly accessible
1 Resources
0 Stars
Publicly accessible
Microhole Test Data
Drilling results from the microhole project at the Sandia High Operating Temperature test facility. The project is seeking to help reduce the cost of exploration and monitoring of geothermal wells and formations by drilling smaller holes. The tests were part of a control algorith...
Su, J. Sandia National Laboratories
May 23, 2016
5 Resources
0 Stars
Publicly accessible
5 Resources
0 Stars
Publicly accessible
Stability of Elastomers Subjected to Geothermal Well-Like Conditions
The aim of this study is to understand how commercially available elastomers perform under geothermal well-like conditions and make recommendations to the community based on these results. This poster highlights the mechanical performance of several elastomers (including EPDM, Vit...
Redline, E. et al Sandia National Laboratories
Aug 10, 2014
1 Resources
0 Stars
Publicly accessible
1 Resources
0 Stars
Publicly accessible
Preliminary performance of HT Datalink
Preliminary performance of high-temperature (HT) high-speed (HS) data link at room temperature over 5000 ft of wireline. The data shows ability of the data link to adapt by decreasing speed.
Cieslewski, G. Sandia National Laboratories
Feb 11, 2014
1 Resources
0 Stars
Publicly accessible
1 Resources
0 Stars
Publicly accessible
SiC Diode High Temperature Test Data
Fabricated SiC diodes are tested in the temperature range of 300 degrees C to 600 degrees C.
Gilbert, G. Sandia National Laboratories
Aug 01, 2014
1 Resources
0 Stars
Publicly accessible
1 Resources
0 Stars
Publicly accessible