Search OEDI Data
Showing results 1 - 25 of 290.
Show
results per page.
Order by:
Available Now:
Research Areas
Accessibility
Data Type
Organization
Source
DCIF (Directional Cooling-Induced Fracturing) Westerly Granite AE Borehole Damage Effect Test (Task 3-0)
Directional Cooling-Induced Fracturing (DCIF) experiments were conducted on three rectangular Westerly granite blocks (width=depth=4.0", height=2.0") which were preheated to 200, 400, and 600 degree C to induce damage (microcracks) with varying degrees. Liquid nitrogen was poured...
Nakagawa, S. Lawrence Berkeley National Laboratory
Jan 27, 2022
13 Resources
0 Stars
Publicly accessible
13 Resources
0 Stars
Publicly accessible
TidGen MHK Generator Composite Fatigue Analysis Procedure
A procedure was described for performing a fatigue analysis of composite foils for an MHK generator. The steps included generating load data, S-N (Stress versus Number of cycles to failure) diagrams through fatigue testing, cycle counts, damage versus load, and cumulative damage. ...
Krumpe, A. ORPC Inc.
Apr 14, 2020
2 Resources
0 Stars
Publicly accessible
2 Resources
0 Stars
Publicly accessible
Advanced TidGen Power System Composites Structural Testing
Seawater aging response was investigated in marine-grade glass/epoxy, glass/vinyl ester, carbon/epoxy and carbon/vinyl ester composites with respect to water uptake, interlaminar shear strength, flexural strength, tensile strength, and tensile fracture surface observations. The re...
Krumpe, A. ORPC Inc.
Jan 06, 2020
2 Resources
0 Stars
Publicly accessible
2 Resources
0 Stars
Publicly accessible
Analysis of Joist Masonry Moisture Content Monitoring
BSC TO5 Task 7.2 Analysis of Joist Masonry Moisture Content Monitoring
House Lawrence, MA 01840
This work involved the field monitoring of embedded wood joist ends in a solid brick building in zone 5A that was retrofitted with interior insulation. Eleven joists throughout the bui...
Ueno, K. Building Science Corporation
Apr 27, 2016
3 Resources
0 Stars
Publicly accessible
3 Resources
0 Stars
Publicly accessible
2014 Wind Turbine Gearbox Damage Distribution based on the NREL Gearbox Reliability Database
Despite the improvements in wind turbine gearbox design and manufacturing practices, the wind industry is still challenged by premature wind turbine gearbox failures. To help address this industry-wide challenge, a consortium called the Gearbox Reliability Collaborative (GRC) was ...
Sheng, S. National Renewable Energy Laboratory
Feb 09, 2015
1 Resources
0 Stars
In curation
1 Resources
0 Stars
In curation
Wind Turbine Gearbox Condition Monitoring Vibration Analysis Benchmarking Datasets
Wind turbine condition monitoring (CM) can potentially help the wind industry reduce turbine downtime and operation and maintenance (O&M) cost. NREL CM research has investigated various condition-monitoring techniques such as acoustic emission (AE specifically stress wave), vibrat...
Sheng, S. National Renewable Energy Laboratory
Mar 28, 2014
5 Resources
2 Stars
Publicly accessible
5 Resources
2 Stars
Publicly accessible
Moisture Risk in Unvented Attics Due to Air Leakage Paths Minneapolis Minnesota
IBACOS completed an initial analysis of moisture damage potential in an unvented attic insulated with closed-cell spray polyurethane foam. To complete this analysis, the research team collected field data, used computational fluid dynamics to quantify the airflow rates through ind...
Rapport, A. et al Ibacos Innovation
Apr 27, 2016
6 Resources
0 Stars
Publicly accessible
6 Resources
0 Stars
Publicly accessible
Foam Fracturing Study for Stimulation Development of Enhanced Geothermal Systems
This is a final technical report for the project: Foam Fracturing Study for Stimulation Development of Enhanced Geothermal Systems (EGS). The goal is to demonstrate the feasibility of foam fracturing in EGS applications. The project, led by Oak Ridge National Laboratory (ORNL), wa...
Wang, H. et al Oak Ridge National Laboratory
May 17, 2022
3 Resources
0 Stars
Publicly accessible
3 Resources
0 Stars
Publicly accessible
Ground Source Heat Pump Parameter Survey
The purpose of this report is to investigate the effects of various parameters in a horizontal loop geothermal heat pump system. The obtained values include the temperature distribution over the entire system as well as the exiting temperature and bulk heat rate of the fluid. The ...
Gray, E. Wright State University
Jul 31, 2013
1 Resources
0 Stars
Publicly accessible
1 Resources
0 Stars
Publicly accessible
High-Pressure and High-Temperature (HPHT) Lost Circulation Material (LCM) Testing
High-pressure and high-temperature (HPHT) lost circulation material (LCM) rheology test results, LCM particle size distributions (PSD) analysis, and HPHT LCM fluid loss test results. Three academic papers / reports derived from this research are also presented.
Salehi, S. and Vivas, C. University of Oklahoma
Nov 30, 2021
6 Resources
0 Stars
Publicly accessible
6 Resources
0 Stars
Publicly accessible
Advanced TidGen Power System Material Characterization Program
The TidGen Power System generates emission-free electricity from tidal currents and connects directly into existing grids using smart grid technology. The power system consists of three major subsystems: shore-side power electronics, mooring system, and turbine generator unit (TGU...
Marnagh, C. and McEntee, J. Ocean Renewable Power Company
Jun 14, 2018
2 Resources
0 Stars
Publicly accessible
2 Resources
0 Stars
Publicly accessible
Simulations of Brady's-Type Fault Undergoing CO2 Push-Pull: Pressure-Transient and Sensitivity Analysis
Input and output files used for fault characterization through numerical simulation using iTOUGH2. The synthetic data for the push period are generated by running a forward simulation (input parameters are provided in iTOUGH2 Brady GF6 Input Parameters.txt [InvExt6i.txt]). In gene...
Jung, Y. and Doughty, C. Lawrence Berkeley National Laboratory
Mar 09, 2018
11 Resources
0 Stars
Publicly accessible
11 Resources
0 Stars
Publicly accessible
Utah FORGE: Laboratory Experiments Examining the Effect of Thermal and Mechanical Processes on Hydraulic Transmissivity Evolution
Using laboratory slide-hold-slide experiments, at temperatures from 22 to 200 degrees C, to examine effects of fracture reactivation and quasi-static loading on the evolution of fluid transport properties of simulated fractures in Westerly granite. At all temperatures, the in-plan...
Lockner, D. et al United States Geological Survey
Apr 03, 2023
2 Resources
0 Stars
Publicly accessible
2 Resources
0 Stars
Publicly accessible
Measure Guideline: Deep Energy Enclosure Retrofit for Interior Insulation of Masonry Walls and Flat Roofs
Measure Guideline: Deep Energy Enclosure Retrofit for Zero Energy Ready House Flat Roofs
BSC TO5 Task 7.4 Deep Energy Enclosure Retrofit (DEER) for Interior Insulation of Masonry Walls
Lawrence, MA 01840
This Measure Guideline describes a deep energy enclosure retrofit solution ...
Musunuru, S. et al Building Science Corporation
Apr 27, 2016
5 Resources
0 Stars
Publicly accessible
5 Resources
0 Stars
Publicly accessible
Data of High-Temperature Dynamic LCM Testing Setup
Data from high temperature dynamic sealing tests for various fracture widths, at various temperatures (degrees F), with 5 wt.% bentonite-based mud containing various material fiber contents, at 100 to 400 psi differential pressure.
Data from pressure test and evaluation of the dy...
Magzoub, M. et al University of Oklahoma
May 31, 2021
11 Resources
0 Stars
Publicly accessible
11 Resources
0 Stars
Publicly accessible
TEAMER: Electrically Engaged Undulation System for Unmanned Underwater Vehicles
This TEAMER RFTS 1 (Request for Technical Support) project supported the flume tank testing of a long range, high endurance unmanned underwater vehicle (UUV) to monitor maritime space. Today, battery-powered remotely operated vehicles (ROVs) lack the duration to make persistent, w...
Lu, K. and Datla, R. Pyro-E
Oct 01, 2021
4 Resources
0 Stars
Publicly accessible
4 Resources
0 Stars
Publicly accessible
HydroAir Power Take Off Combined Design Report
The submission is the combined design report for the HydroAir Power Take Off (PTO). CAD drawings, circuit diagrams, design report, test plan, technical specifications and data sheets are included for the Main and auxiliary control cabinets and three-phase-synchronous-motor with a ...
Pearson, G. et al Dresser-Rand Company
Jun 26, 2015
15 Resources
0 Stars
Publicly accessible
15 Resources
0 Stars
Publicly accessible
Kinetics of Chlorite Dissolution at Elevated Temperatures and CO2 Conditions
Chlorite dissolution kinetics were measured under far from equilibrium conditions using a mixed-flow reactor over temperatures of 100-275 degrees C at pH values of 3.0-5.7 in a background solution matrix of 0.05 m NaCl. Over this temperature range, magnesium was released congruent...
Carroll, S. et al Lawrence Livermore National Laboratory
Jul 01, 2013
1 Resources
0 Stars
Publicly accessible
1 Resources
0 Stars
Publicly accessible
Monitoring of Double-Stud Wall Moisture Conditions in the Northeast
BSC TO5 Task 2.2 Monitoring of Double Stud Wall Moisture Conditions in the Northeast
Field test data available for wood moisture contents, temperature, and relative humidity.
STRUCTURE House Devens, MA 01432
Three double-stud assemblies were compared: 12-in. ocSPF, 12-in. cellulo...
Ueno, K. Building Science Corporation
Apr 27, 2016
2 Resources
0 Stars
Publicly accessible
2 Resources
0 Stars
Publicly accessible
Utah FORGE 2-2439v2: Report on Predicting Far-Field Stresses Using Finite Element Modeling and Near-Wellbore Machine Learning for Well 16A(78)-32
This report presents the far-field stress predictions at two locations along the vertical section of Utah FORGE Well 16A (78)-32 using a physics-based thermo-poro-mechanical model. Three principal stresses in far-field were obtained by solving an inverse problem based on the near-...
Lu, G. et al University of Pittsburgh
Aug 30, 2024
2 Resources
0 Stars
Publicly accessible
2 Resources
0 Stars
Publicly accessible
High-Pressure Combustion and Deflagration-to-Detonation Transition in Ethylene/Nitrous Oxide Mixtures
In this paper, the combustion of nitrous oxide with a simple hydrocarbon, ethylene, at high initial pressures is investigated. A series of experiments were conducted using a stoichiometric C2H4-N2O mixture in a round, smooth-walled tube with initial pressures of 125 to 337 psi. ...
Grubelich, M. Sandia National Laboratories
Nov 01, 2013
1 Resources
0 Stars
Publicly accessible
1 Resources
0 Stars
Publicly accessible
Improved Rare Earth Element Sorption from Simulated Geothermal Brines: Effect of Gassed versus Degassed Brines
A study exploring sorption and stripping characteristics of sorption media when simulated geothermal brines are degassed or not degassed. Experiments were done at 70degC. The brines used in this study were formulated by Tusaar. The two brines used/simulated are labeled 1M and 1C...
Stull, D. Tusaar Corp.
May 24, 2016
2 Resources
0 Stars
Publicly accessible
2 Resources
0 Stars
Publicly accessible
DCIF Westerly Granite AE Stress Effect Test (Task 3-1)
Directional Cooling-Induced Fracturing (DCIF) experiments were conducted on rectangular Westerly granite blocks (width=depth=4.0", height=2.0"). Liquid nitrogen was poured in a small, 1"-diameter copper cup attached to the top of the sample, and the resulting acoustic emissions (A...
Nakagawa, S. and Trzeciak, M. Lawrence Berkeley National Laboratory
Jul 08, 2021
15 Resources
0 Stars
Publicly accessible
15 Resources
0 Stars
Publicly accessible
REE Adsorption Performance with Immobilized Caulobacter Biofilms
This submission includes data collected from experiments on the performance of rare earth adsorption by immobilized bacteria that accompany the FY18 Q2 and Q3 quarter reports. Relevant information from these reports is included in a resource below. The spreadsheet below includes d...
Jiao, Y. and Park, D. Lawrence Livermore National Laboratory
Apr 01, 2018
2 Resources
0 Stars
Publicly accessible
2 Resources
0 Stars
Publicly accessible
CO2 Push-Pull Single Fault Injection Simulations
ASCII text files containing grid-block name, X-Y-Z location, and multiple parameters from TOUGH2 simulation output of CO2 injection into an idealized single fault representing a dipping normal fault at the Desert Peak geothermal field (readable by GMS). The fault is composed of a ...
Borgia, A. et al Lawrence Berkeley National Laboratory
Sep 21, 2017
5 Resources
0 Stars
Publicly accessible
5 Resources
0 Stars
Publicly accessible