Search OEDI Data
Showing results 1 - 25 of 451.
Show
results per page.
Order by:
Available Now:
Research Areas
Accessibility
Data Type
Organization
Source
Preliminary performance of HT Datalink
Preliminary performance of high-temperature (HT) high-speed (HS) data link at room temperature over 5000 ft of wireline. The data shows ability of the data link to adapt by decreasing speed.
Cieslewski, G. Sandia National Laboratories
Feb 11, 2014
1 Resources
0 Stars
Publicly accessible
1 Resources
0 Stars
Publicly accessible
Auto Indexer Auto-Indexer for Percussive Hammers: Vane Motor Dynamometer Testing
Objectives
Options associated with geothermal drilling operations are generally limited by factors such as formation temperature and rock strength. The objective of the research is to expand the "tool box" available to the geothermal driller by furthering the development of a hig...
Su, J. Sandia National Laboratories
Jan 01, 2012
1 Resources
0 Stars
Publicly accessible
1 Resources
0 Stars
Publicly accessible
Adsorption Heat Pump Coatings Investigation
In this study, a theoretical investigation was made to predict the performances of zeolite Y and SAPO-34 coatings for an adsorption cooling system operated by waste heat, under various conditions. A mathematical model developed and tested previously for coatings of A and X type ze...
Tatlier, M. Istanbul Technical University
May 22, 2020
2 Resources
0 Stars
Publicly accessible
2 Resources
0 Stars
Publicly accessible
Performance and Costs of Ductless Heat Pumps in Marine-Climate High-Performance Homes Habitat for Humanity The Woods
The Washington State University (WSU) Energy Program's Building America (BA) team conducted a case study of a high-performance affordable housing community: The Woods (Figure 1). This BA effort is part of a larger-scale study of 30 homes funded from 2013-2016 by Tacoma Public Util...
Lubliner, M. et al Washington State University
Apr 27, 2016
8 Resources
0 Stars
Publicly accessible
8 Resources
0 Stars
Publicly accessible
Comfort in High-Performance Homes in a Hot-Humid Climate
TO5 2.3.2: Large-Scale Temperature Study
Although space-conditioning systems are required to meet standards such as those in the Air Conditioning Contractors of America (ACCA) Manual RS (Rutkowski 1997) and the ASHRAE Standard 55 (ASHRAE 2013) comfort criteria, little is known ab...
Poerschke, A. and Beach, R. Ibacos Innovation
Apr 27, 2016
3 Resources
0 Stars
Publicly accessible
3 Resources
0 Stars
Publicly accessible
Measured Performance of a Varied Airflow Small-Diameter Duct System
In this study, researchers with the U.S. Department of Energy's Building America team IBACOS built on research previously done in two new-construction unoccupied test houses-one in Pittsburgh, Pennsylvania (Poerschke and Stecher 2014) and one in Fresno, California (Stecher and Poe...
Poerschke, A. Ibacos Innovation
Apr 27, 2016
5 Resources
0 Stars
Publicly accessible
5 Resources
0 Stars
Publicly accessible
Testing LCM on a Large Scale for Geothermal Drilling Applications Using a Novel Experimental Setup
Rheology data obtained from flow loop tests, performed using different lost circulation materials (LCM) to study their effect on fluid rheology and wellbore hydraulics. The sealing performance of different LCM was tested using different fracture sizes. Five academic papers / repor...
Mohamed, A. et al University of Oklahoma
Apr 22, 2022
10 Resources
0 Stars
Publicly accessible
10 Resources
0 Stars
Publicly accessible
Evaluation of the Performance of Houses With and Without Supplemental Dehumidification in a Hot-Humid Climate
Understanding indoor humidity conditions in low energy homes in hot-humid climates is critical to promoting long term occupant comfort, indoor air quality and building durability. The results of this study were expected to inform the residential building community on whether suppl...
Kerrigan, P. and Norton, P. National Renewable Energy Laboratory
Apr 27, 2016
7 Resources
0 Stars
Publicly accessible
7 Resources
0 Stars
Publicly accessible
Lost Circulation Materials in Geothermal Drilling: Thermal Degradation, Viscosity, Compression, and Flow Loop Tests
This dataset provides a set of experimental data on the performance of lost circulation materials (LCMs) used in geothermal drilling operations. It includes results from four distinct tests: thermal degradation, viscosity measurements, compression tests, and high-temperature flow ...
Kibikas, W. et al Sandia National Laboratories
Feb 01, 2022
9 Resources
0 Stars
Publicly accessible
9 Resources
0 Stars
Publicly accessible
The Performance House: A Cold Climate Challenge Home Old Greenwich
Working with builder partners on test homes allows for vetting of whole-house building strategies to eliminate any potential unintended consequences prior to implementing these solution packages on a production scale. To support this research, the Consortium for Advanced Residenti...
Williamson, J. et al Steven Winter Associates of the Consortium for Advanced Residential Buildings
Apr 27, 2016
4 Resources
0 Stars
Publicly accessible
4 Resources
0 Stars
Publicly accessible
Comparative Analysis of Alternative Means for Removing Noncondensable Gases from Flashed-Steam Geothermal Power Plants:April 1999 March 2000
This dataset corresponds to the final report on a screening study to compare six methods of removing noncondensable gases from direct-use geo-thermal steam power plants. This report defines the study methodologies and compares the performance and economics of selected gas-removal ...
Hallett, K. and Laboratory, N. National Renewable Energy Laboratory
Nov 25, 2014
3 Resources
0 Stars
In curation
3 Resources
0 Stars
In curation
Comparative Performance of Four Prototype Mechanical Building Cooling Systems in a Desert Climate
Data and result of approximately fifteen months of monitoring of four houses located in the desert climate of Borrego Springs, California. Four houses were constructed using identical floor plans but differing wall materials, and different cooling systems that were designed to red...
Springer, D. et al Davis Energy
Jul 20, 2016
9 Resources
0 Stars
Publicly accessible
9 Resources
0 Stars
Publicly accessible
Advancing Replicable Solutions for High-Performance Homes in the Southeast JMC Patrick Square
The work presented in this report advances the goals of the U.S. Department of Energy Building America program by improving the energy peformance of affordable and market-rate housing. Southface Energy Institute (Southface), part of the U.S. Department of Energy Building America r...
Sweet, M. et al Southface
Apr 27, 2016
3 Resources
0 Stars
Publicly accessible
3 Resources
0 Stars
Publicly accessible
TEAMER: MADWEC Techno-Economic Analysis
The objective of this project was for the facility to conduct a techno-economic assessment (TEA) of the Maximal Asymmetric Drag Wave Energy Converter (MADWEC), developed by the University of Massachusetts Dartmouth (UMass Dartmouth). MADWEC is used for powering remote monitoring a...
Ortega, T. and Baca, E. National Renewable Energy Laboratory
Mar 08, 2024
2 Resources
0 Stars
Publicly accessible
2 Resources
0 Stars
Publicly accessible
Analysis of Pre-Retrofit Building and Utility Data Southeast United States
TO4 9.1.2: Comm. Scale Military Housing Upgrades
This project delves into the workflow and results of regression models on monthly and daily utility data (meter readings of electricity consumption), outlining a process for screening and gathering useful results from inverse model...
Beach, R. and Prahl, D. Ibacos Innovation
Apr 27, 2016
12 Resources
0 Stars
In curation
12 Resources
0 Stars
In curation
PV_window_building_study
Data associated with the paper “Photovoltaic Windows to Offset the Intensive Energy and Carbon Footprints of Highly Glazed Buildings” by Vincent M. Wheeler, Janghyun Kim, Tom Daligault, Bryan Rosales, Chaiwat Engtrakul, Robert C. Tenent, and Lance M. Wheeler
WheelerNational Renewable Energy Laboratory
Oct 23, 2022
1 Resources
0 Stars
Publicly accessible
1 Resources
0 Stars
Publicly accessible
High Temperature Chemical Sensing Tool: Preliminary pH and reference electrode test results
Project: High Temperature Chemical Sensing Tool for Distributed Mapping of Fracture Flow in EGS. Preliminary pH and reference electrode test results.
Cieslewski, G. Sandia National Laboratories
Sep 30, 2014
6 Resources
0 Stars
Publicly accessible
6 Resources
0 Stars
Publicly accessible
Conway St Apartments Olive Street Development
In Greenfield, Massachusetts, Olive Street Development transformed an old elementary school building into 12 high-end rental apartments. The developer aimed to get as close to net-zero performance as practical, installing: (1) R-30 high-density spray foam against the brick walls (...
Aldrich, R. and Williamson, J. Steven Winter Associates of the Consortium for Advanced Residential Buildings
Apr 27, 2016
2 Resources
0 Stars
In curation
2 Resources
0 Stars
In curation
New Mexico Play Fairway Analysis: Wells and Springs with Discharge Temperature Higher than 30 deg C
This submission includes three files from two sources. One file is derived from USGS data and includes a series of manipulations to evaluate only shallow wells with high estimated geothermal gradients. Two other files are springs and wells with discharge temperatures above 30 deg...
Kelley, S. New Mexico Bureau of Geology and Mineral Resources
Jun 16, 2015
3 Resources
0 Stars
Publicly accessible
3 Resources
0 Stars
Publicly accessible
Dataset for Evaluation of Extreme Weather Impacts on Utility-Scale Photovoltaic Plant Performance in the United States
This dataset is a fusion of three data types (operations and maintenance tickets, weather data, and production data) that was used to support machine learning analysis and evaluation of drivers for low performance at photovoltaic (PV) sites during compound, extreme weather events....
Gunda, T. and Jackson, N. Sandia National Laboratories
Apr 01, 2021
2 Resources
0 Stars
Publicly accessible
2 Resources
0 Stars
Publicly accessible
Measure Guideline: Deep Energy Enclosure Retrofit for Interior Insulation of Masonry Walls and Flat Roofs
Measure Guideline: Deep Energy Enclosure Retrofit for Zero Energy Ready House Flat Roofs
BSC TO5 Task 7.4 Deep Energy Enclosure Retrofit (DEER) for Interior Insulation of Masonry Walls
Lawrence, MA 01840
This Measure Guideline describes a deep energy enclosure retrofit solution ...
Musunuru, S. et al Building Science Corporation
Apr 27, 2016
5 Resources
0 Stars
Publicly accessible
5 Resources
0 Stars
Publicly accessible
High-Pressure and High-Temperature (HPHT) Lost Circulation Material (LCM) Testing
High-pressure and high-temperature (HPHT) lost circulation material (LCM) rheology test results, LCM particle size distributions (PSD) analysis, and HPHT LCM fluid loss test results. Three academic papers / reports derived from this research are also presented.
Salehi, S. and Vivas, C. University of Oklahoma
Nov 30, 2021
6 Resources
0 Stars
Publicly accessible
6 Resources
0 Stars
Publicly accessible
Brookfield Homes Passive House Performance Evaluation
TO4 3.1.3: Brookfield Homes Short-Term Results
TO5 3.1.3: Brookfield Passive House Monitoring
To further define its market position on high performance homebuilding, Brookfield worked with IBACOS and the Building America program to design and construct a Passive House (PH) certif...
Beach, R. et al Ibacos Innovation
Apr 27, 2016
4 Resources
0 Stars
Publicly accessible
4 Resources
0 Stars
Publicly accessible
Recovery of Rare Earths, Precious Metals and Other Critical Materials from Geothermal Waters with Advanced Sorbent Structures
The work evaluates, develops and demonstrates flexible, scalable mineral extraction technology for geothermal brines based upon solid phase sorbent materials with a specific focus upon rare earth elements (REEs). The selected organic and inorganic sorbent materials demonstrated h...
Addleman, R. et al Pacific Northwest National Laboratory
Sep 30, 2015
2 Resources
0 Stars
Publicly accessible
2 Resources
0 Stars
Publicly accessible
Data of High-Temperature Dynamic LCM Testing Setup
Data from high temperature dynamic sealing tests for various fracture widths, at various temperatures (degrees F), with 5 wt.% bentonite-based mud containing various material fiber contents, at 100 to 400 psi differential pressure.
Data from pressure test and evaluation of the dy...
Magzoub, M. et al University of Oklahoma
May 31, 2021
11 Resources
0 Stars
Publicly accessible
11 Resources
0 Stars
Publicly accessible