Confined Brazilian Tests for Rock Failure Envelope and Behavior
Includes test data from Confined Brazilian Tests. The tests were aim at investigating the rock failure envelope of four different lithologies including Indiana limestone, Scioto sandstone, Grey Berea sandstone, and Tennessee sandstone. Tables include the strength data obtained usi...
Ghassemi, A. and Li, Y. University of Oklahoma
Aug 31, 2021
2 Resources
0 Stars
Publicly accessible
2 Resources
0 Stars
Publicly accessible
TidGen MHK Generator Composite Fatigue Analysis Procedure
A procedure was described for performing a fatigue analysis of composite foils for an MHK generator. The steps included generating load data, S-N (Stress versus Number of cycles to failure) diagrams through fatigue testing, cycle counts, damage versus load, and cumulative damage. ...
Krumpe, A. ORPC Inc.
Apr 14, 2020
2 Resources
0 Stars
Publicly accessible
2 Resources
0 Stars
Publicly accessible
DCIF (Directional Cooling-Induced Fracturing) Westerly Granite AE Borehole Damage Effect Test (Task 3-0)
Directional Cooling-Induced Fracturing (DCIF) experiments were conducted on three rectangular Westerly granite blocks (width=depth=4.0", height=2.0") which were preheated to 200, 400, and 600 degree C to induce damage (microcracks) with varying degrees. Liquid nitrogen was poured...
Nakagawa, S. Lawrence Berkeley National Laboratory
Jan 27, 2022
13 Resources
0 Stars
Publicly accessible
13 Resources
0 Stars
Publicly accessible
2014 Wind Turbine Gearbox Damage Distribution based on the NREL Gearbox Reliability Database
Despite the improvements in wind turbine gearbox design and manufacturing practices, the wind industry is still challenged by premature wind turbine gearbox failures. To help address this industry-wide challenge, a consortium called the Gearbox Reliability Collaborative (GRC) was ...
Sheng, S. National Renewable Energy Laboratory
Feb 09, 2015
1 Resources
0 Stars
In curation
1 Resources
0 Stars
In curation
Moisture Risk in Unvented Attics Due to Air Leakage Paths Minneapolis Minnesota
IBACOS completed an initial analysis of moisture damage potential in an unvented attic insulated with closed-cell spray polyurethane foam. To complete this analysis, the research team collected field data, used computational fluid dynamics to quantify the airflow rates through ind...
Rapport, A. et al Ibacos Innovation
Apr 27, 2016
6 Resources
0 Stars
Publicly accessible
6 Resources
0 Stars
Publicly accessible
Gas Propagated Borehole Fracture Model And Simulation
We developed a model for fracture production produced during detonation of an explosive mixture in a 10m packed off section of a shallow borehole. The model is based upon an actual field and lab experiments on low-damage borehole fracturing performed at Sandia National Labs by Mar...
Carrigan, C. Lawrence Livermore National Laboratory
Nov 15, 2015
1 Resources
0 Stars
Publicly accessible
1 Resources
0 Stars
Publicly accessible
High-Temperature Inorganic Self-Healing Inorganic Cement Composites
The data files below summarize the results from various experiments testing properties of high-temperature self-healing inorganic cement composites. These properties include cement-carbon steel bond strength, Young's modulus recovery, matrix recovery strength, and compressive stre...
Pyatina, T. and Sugama, T. Brookhaven National Laboratory
Sep 13, 2017
5 Resources
0 Stars
Publicly accessible
5 Resources
0 Stars
Publicly accessible
Advanced TidGen Power System Composites Structural Testing
Seawater aging response was investigated in marine-grade glass/epoxy, glass/vinyl ester, carbon/epoxy and carbon/vinyl ester composites with respect to water uptake, interlaminar shear strength, flexural strength, tensile strength, and tensile fracture surface observations. The re...
Krumpe, A. ORPC Inc.
Jan 06, 2020
2 Resources
0 Stars
Publicly accessible
2 Resources
0 Stars
Publicly accessible
Simulations of Brady's-Type Fault Undergoing CO2 Push-Pull: Pressure-Transient and Sensitivity Analysis
Input and output files used for fault characterization through numerical simulation using iTOUGH2. The synthetic data for the push period are generated by running a forward simulation (input parameters are provided in iTOUGH2 Brady GF6 Input Parameters.txt [InvExt6i.txt]). In gene...
Jung, Y. and Doughty, C. Lawrence Berkeley National Laboratory
Mar 09, 2018
11 Resources
0 Stars
Publicly accessible
11 Resources
0 Stars
Publicly accessible
Wind Turbine Gearbox Condition Monitoring Vibration Analysis Benchmarking Datasets
Wind turbine condition monitoring (CM) can potentially help the wind industry reduce turbine downtime and operation and maintenance (O&M) cost. NREL CM research has investigated various condition-monitoring techniques such as acoustic emission (AE specifically stress wave), vibrat...
Sheng, S. National Renewable Energy Laboratory
Mar 28, 2014
5 Resources
2 Stars
Publicly accessible
5 Resources
2 Stars
Publicly accessible
Analysis of Joist Masonry Moisture Content Monitoring
BSC TO5 Task 7.2 Analysis of Joist Masonry Moisture Content Monitoring
House Lawrence, MA 01840
This work involved the field monitoring of embedded wood joist ends in a solid brick building in zone 5A that was retrofitted with interior insulation. Eleven joists throughout the bui...
Ueno, K. Building Science Corporation
Apr 27, 2016
3 Resources
0 Stars
Publicly accessible
3 Resources
0 Stars
Publicly accessible
Measure Guideline: Deep Energy Enclosure Retrofit for Interior Insulation of Masonry Walls and Flat Roofs
Measure Guideline: Deep Energy Enclosure Retrofit for Zero Energy Ready House Flat Roofs
BSC TO5 Task 7.4 Deep Energy Enclosure Retrofit (DEER) for Interior Insulation of Masonry Walls
Lawrence, MA 01840
This Measure Guideline describes a deep energy enclosure retrofit solution ...
Musunuru, S. et al Building Science Corporation
Apr 27, 2016
5 Resources
0 Stars
Publicly accessible
5 Resources
0 Stars
Publicly accessible
Chemical, Calcium Phosphate Cements for Geothermal Wells Corrosion Protection, Bond Strength and Matrix Self-Healing
The data set shows performance of economical calcium phosphate cement (Fondu) blended with fly ash, class F (FAF) in carbon steel corrosion protection tests (corrosion rate, corrosion current and potential), bond and matrix strength, as well as matrix strength recovery after impos...
Sugama, T. Brookhaven National Laboratory
Sep 26, 2017
2 Resources
0 Stars
Publicly accessible
2 Resources
0 Stars
Publicly accessible
Washington State Play Fairway Analysis Passive Monitoring of St. Helens Shear Zone for Tomography and Precision Microseismic Event Detection
Data resources were derived from a passive seismic survey of the northern St. Helens Shear Zone on geothermal leases 12-24 km north of Mount St. Helens for phase 2 of the Geothermal Play-Fairway Analysis of Washington State Prospects. A 20 seismic station array of broadband seismo...
Swyer, M. et al AltaRock Energy Inc
Oct 03, 2017
7 Resources
0 Stars
Publicly accessible
7 Resources
0 Stars
Publicly accessible
CO2 Push-Pull Single Fault Injection Simulations
ASCII text files containing grid-block name, X-Y-Z location, and multiple parameters from TOUGH2 simulation output of CO2 injection into an idealized single fault representing a dipping normal fault at the Desert Peak geothermal field (readable by GMS). The fault is composed of a ...
Borgia, A. et al Lawrence Berkeley National Laboratory
Sep 21, 2017
5 Resources
0 Stars
Publicly accessible
5 Resources
0 Stars
Publicly accessible
Material Properties for Brady Hot Springs Nevada USA from PoroTomo Project
The PoroTomo team has completed inverse modeling of the three data sets (seismology, geodesy, and hydrology) individually, as described previously. The estimated values of the material properties are registered on a three-dimensional grid with a spacing of 25 meters between nodes....
Feigl, K. and PoroTomo Team, . University of Wisconsin
Mar 06, 2019
10 Resources
0 Stars
Publicly accessible
10 Resources
0 Stars
Publicly accessible
Spray Foam Exterior Insulation with Stand-Off Furring New York
IBACOS and Green Homes America 1 (GHA) collaborated with the New York State Energy Research and Development Authority (NYSERDA) Advanced Buildings Program to research a variation of a commercial curtain wall assembly for residential construction as part of a comprehensive whole-ho...
Rapport, A. et al Ibacos Innovation
Apr 27, 2016
2 Resources
0 Stars
Publicly accessible
2 Resources
0 Stars
Publicly accessible
Evaluation of Crawlspace Retrofits in Multifamily Buildings
In 2011 and early 2012, Building Science Corporation (BSC) collaborated with Innova Services Corporation on a multifamily community un-vented crawlspace retrofit project at Oakwood Gardens in Lansdale, Pennsylvania. BSC provided design consulting services and pre and post-retrofit...
Rudd, A. Advanced Building Systems
Apr 27, 2016
41 Resources
0 Stars
Publicly accessible
41 Resources
0 Stars
Publicly accessible