Transient Cold-Climate Building Foundation Hygrothermal Experimental Data
The data consist of two years of continuous transient experimental measurements on the hygrothermal performance of concrete masonry block walls in a full basement in a cold climate (US DOE climate zone 7). The walls were insulated in compliance with the thermal requirements of the...
Merket, N. and Laboratory, N. National Renewable Energy Laboratory
Jun 30, 2015
4 Resources
0 Stars
In curation
4 Resources
0 Stars
In curation
Field Testing Unvented Roofs with Asphalt Shingles in Cold and Hot-humid Climates
BSC TO5 Task 7.1 Field Testing Unvented Roofs with Asphalt Shingles in Cold Climates Bolingbrook, IL 60440
BSC TO5 Task 7.1 Field Testing Unvented Roofs with Asphalt Shingles in Hot-Humid Climates Friendswood, TX 77546
To understand the long-term moisture performance of unvented ...
Ueno, K. and Lstiburek, J. Building Science Corporation
Apr 27, 2016
3 Resources
0 Stars
Publicly accessible
3 Resources
0 Stars
Publicly accessible
The Performance House: A Cold Climate Challenge Home Old Greenwich
Working with builder partners on test homes allows for vetting of whole-house building strategies to eliminate any potential unintended consequences prior to implementing these solution packages on a production scale. To support this research, the Consortium for Advanced Residenti...
Williamson, J. et al Steven Winter Associates of the Consortium for Advanced Residential Buildings
Apr 27, 2016
4 Resources
0 Stars
Publicly accessible
4 Resources
0 Stars
Publicly accessible
Ocean Thermal Energy Conversion (OTEC) Cold Water Depth (Annual Average)
This shapefile represents annual average cold water depth recordings.
The cold water is defined by locating the depth that leads to the greatest average annual net power at each location when depth and its corresponding ?T are input into the power equation. This optimization ba...
Langle, N. and Laboratory, N. National Renewable Energy Laboratory
Nov 25, 2014
2 Resources
0 Stars
In curation
2 Resources
0 Stars
In curation
Ocean Thermal Energy Conversion (OTEC) Cold Water Depth (Summer Average)
This shapefile represents seasonal summer average cold water depth recordings.
The cold water is defined by locating the depth that leads to the greatest average annual net power at each location when depth and its corresponding ΔT are input into the power equation. This optim...
Langle, N. and Laboratory, N. National Renewable Energy Laboratory
Nov 25, 2014
2 Resources
0 Stars
In curation
2 Resources
0 Stars
In curation
Ocean Thermal Energy Conversion (OTEC) Cold Water Depth (Winter Average)
This shapefile represents seasonal winter average cold water depth recordings.
The cold water is defined by locating the depth that leads to the greatest average annual net power at each location when depth and its corresponding ΔT are input into the power equation. This optim...
Langle, N. and Laboratory, N. National Renewable Energy Laboratory
Nov 25, 2014
2 Resources
0 Stars
In curation
2 Resources
0 Stars
In curation
Retrofitting a 1960s Split-Level Cold-Climate Home
The U.S. Department of Energy Building America research team Consortium for Advanced Residential Buildings (CARB) partnered with Preferred Builders, a previous CARB partner and builder of the Performance House (DOE 2013) and the owners of a 1960s split-level home in Westport, Conn...
Puttagunta, S. Steven Winter Associates of the Consortium for Advanced Residential Buildings
Apr 27, 2016
3 Resources
0 Stars
Publicly accessible
3 Resources
0 Stars
Publicly accessible
NorthernSTAR Project Overcoat: Exterior Insulation Strategies for 1.5-Story Roof Applications in Cold Climates
This is a repository for all NorthernSTAR Overcoat insulation retrofit projects. Both houses received Overcoat insulation retrofit on roof only, performed by Cocoon Insulation.
1 St. Louis Park house St. Louis Park, MN
2 Edina house Edina, MN
In this second study, the team wishe...
Jacobson, R. et al University of Minnesota NorthernSTAR Building America Partnership
Apr 27, 2016
10 Resources
0 Stars
Publicly accessible
10 Resources
0 Stars
Publicly accessible
NorthernSTAR 1.5-Story Demonstration House of Cold Climate Solutions for Affordable Housing
This is a NorthernSTAR renovation project for Urban Homeworks incorporating installation of a combination space and water heater, Overcoat insulation retrofit on the roof, and Excavationless foundation insulation retrofit.
STRUCTURE 1401 North 16th Ave Minneapolis, MN 55411
Var...
Jacobson, R. et al University of Minnesota NorthernSTAR Building America Partnership
Apr 27, 2016
12 Resources
0 Stars
Publicly accessible
12 Resources
0 Stars
Publicly accessible
Ocean Thermal Energy Conversion (OTEC) delta T (Winter Average)
This shapefile represents seasonal winter average delta T estimates.
ΔT represents the difference in temperature (°C) between the warm and cold water sources used by an OTEC plant at a specific location. Warm water is defined uniformly as water at a depth of 20 m, whi...
ΔT represents the difference in temperature (°C) between the warm and cold water sources used by an OTEC plant at a specific location. Warm water is defined uniformly as water at a depth of 20 m, whi...
Langle, N. and Laboratory, N. National Renewable Energy Laboratory
Nov 25, 2014
2 Resources
0 Stars
In curation
2 Resources
0 Stars
In curation
1D Heat Loss Models Validation Experiment
Contains data from the model validation in the 1D Heat Loss Models to Predict the Aquifer Temperature Profile during Hot/Cold Water Injection Project. The data include two COMSOL models (2D axisymmetric benchmark model and 2D Vinsome model), one python code (1D Vinsome based FEM n...
Chen, K. et al UC Berkeley
Jan 18, 2022
8 Resources
0 Stars
Publicly accessible
8 Resources
0 Stars
Publicly accessible
NorthernStar Zero Energy Ready Homes
This is a repository for all NorthernSTAR Zero Energy Ready certified homes.
Amaris Homes Model Home St. Paul, MN 55110
Description: Model home completed September 2013
The DOE Zero Energy Ready Home Case Study looks to study and eventually design zero net energy homes in cold we...
Huelman, P. University of Minnesota NorthernSTAR Building America Partnership
Apr 27, 2016
20 Resources
0 Stars
Publicly accessible
20 Resources
0 Stars
Publicly accessible
Lancaster County Career and Technology Center (LCCTC) Green Homes
With the support of the U.S. Department of Energy (DOE) Building America Program, Home Innovation Research Labs partnered with Lancaster County Career and Technology Center (LCCTC) to build a third new construction test house (NCTH) in Apprentice Green, a community next to the sch...
Kochkin, V. et al Home Innovation Research Labs National Association of Home Builders
Apr 27, 2016
3 Resources
0 Stars
Publicly accessible
3 Resources
0 Stars
Publicly accessible
Excavationless Exterior Foundation Insulation Field Study Minnesota
The NorthernSTAR Building America Partnership team implemented an innovative, minimally invasive foundation insulation upgrade technique on an existing home. The approach consisted of using hydrovac excavation technology combined with a liquid insulating foam. Two houses were orig...
Jacobson, R. et al University of Minnesota NorthernSTAR Building America Partnership
Apr 27, 2016
11 Resources
0 Stars
Publicly accessible
11 Resources
0 Stars
Publicly accessible
Measured Performance of a Varied Airflow Small-Diameter Duct System
In this study, researchers with the U.S. Department of Energy's Building America team IBACOS built on research previously done in two new-construction unoccupied test houses-one in Pittsburgh, Pennsylvania (Poerschke and Stecher 2014) and one in Fresno, California (Stecher and Poe...
Poerschke, A. Ibacos Innovation
Apr 27, 2016
5 Resources
0 Stars
Publicly accessible
5 Resources
0 Stars
Publicly accessible
National Renewable Energy Laboratory/Habitat for Humanity Zero Energy Home: A Cold Climate Case Study for Affordable Zero Energy Homes
The design of this 1,280-square-foot, three-bedroom Habitat for Humanity of Metro Denver zero energy home carefully combines envelope efficiency, efficient equipment, appliances and lighting, and passive and active solar features to reach the zero energy goal. The home was designe...
Norton, P. et al National Renewable Energy Laboratory
Jul 21, 2016
4 Resources
0 Stars
Publicly accessible
4 Resources
0 Stars
Publicly accessible
New York State Energy Research and Development Authority Exterior Building Solutions To Insulation
TO4 8.2.2: Space Cond. for Deep Energy Retrofits
The purpose of this project for the New York State Energy Research and Development Authority (NYSERDA) is to find new or improved strategies for exterior building solutions in regard to insulation that will provide extensive energy...
Beach, R. et al Ibacos Innovation
Apr 27, 2016
14 Resources
0 Stars
Publicly accessible
14 Resources
0 Stars
Publicly accessible
Ocean Thermal Energy Conversion (OTEC) delta T (Annual Average)
This shapefile represents annual average delta T estimates.
ΔT represents the difference in temperature (°C) between the warm and cold water sources used by an OTEC plant at a specific location. Warm water is defined uniformly as water at a depth of 20 m, while cold water is ...
Langle, N. and Laboratory, N. National Renewable Energy Laboratory
Nov 25, 2014
2 Resources
0 Stars
In curation
2 Resources
0 Stars
In curation
Ocean Thermal Energy Conversion (OTEC) delta T (Summer Average)
This shapefile represents seasonal summer average delta T estimates.
ΔT represents the difference in temperature (°C) between the warm and cold water sources used by an OTEC plant at a specific location. Warm water is defined uniformly as water at a depth of 20 m, while cold ...
Langle, N. and Laboratory, N. National Renewable Energy Laboratory
Nov 25, 2014
2 Resources
0 Stars
In curation
2 Resources
0 Stars
In curation
Mechanical Ventilation and Indoor Air Quality in Recently Constructed U.S. Homes in Marine and Cold-Dry Climates Data from Building America Project
Data were collected to characterize whole-house mechanical ventilation (WHMV) and indoor air quality (IAQ) in 55 homes in the Marine climate of Oregon and Cold-Dry climate of Colorado in the U.S. Sixteen homes were monitored for two weeks, with and without WHMV operating. Ventilat...
Zhao, H. et al Lawrence Berkeley National Laboratory
Mar 22, 2023
2 Resources
0 Stars
Publicly accessible
2 Resources
0 Stars
Publicly accessible
Commercial and Residential Hourly Load Profiles for all TMY3 Locations in the United States
Note: This dataset has been superseded by the dataset found at "End-Use Load Profiles for the U.S. Building Stock" (submission 4520; linked in the submission resources), which is a comprehensive and validated representation of hourly load profiles in the U.S. commercial and reside...
Ong, S. and Clark, N. National Renewable Energy Laboratory
Nov 25, 2014
22 Resources
1 Stars
Publicly accessible
22 Resources
1 Stars
Publicly accessible
Control Strategies to Reduce the Energy Consumption of Central Domestic Hot Water Systems
Domestic hot water (DHW) is the second-largest energy end use in U.S. buildings; it is exceeded only by space conditioning. In this study, the U.S. Department of Energy's Building America research team Advanced Research Integrated Energy Solutions installed and tested two types o...
Dentz, J. et al The Levy Partnership, Inc Systems Building Research Alliance
Apr 27, 2016
3 Resources
0 Stars
Publicly accessible
3 Resources
0 Stars
Publicly accessible
Monitoring of Double-Stud Wall Moisture Conditions in the Northeast
BSC TO5 Task 2.2 Monitoring of Double Stud Wall Moisture Conditions in the Northeast
Field test data available for wood moisture contents, temperature, and relative humidity.
STRUCTURE House Devens, MA 01432
Three double-stud assemblies were compared: 12-in. ocSPF, 12-in. cellulo...
Ueno, K. Building Science Corporation
Apr 27, 2016
2 Resources
0 Stars
Publicly accessible
2 Resources
0 Stars
Publicly accessible
Analysis of Joist Masonry Moisture Content Monitoring
BSC TO5 Task 7.2 Analysis of Joist Masonry Moisture Content Monitoring
House Lawrence, MA 01840
This work involved the field monitoring of embedded wood joist ends in a solid brick building in zone 5A that was retrofitted with interior insulation. Eleven joists throughout the bui...
Ueno, K. Building Science Corporation
Apr 27, 2016
3 Resources
0 Stars
Publicly accessible
3 Resources
0 Stars
Publicly accessible
Thermostatic Radiator Valve Evaluation and Demonstration
A large stock of multifamily buildings in the Northeast and Midwest uses hot water or steam for space heating. Typically, residents do not pay for heat directly (i.e., heating fuel serves a central plant and use is not submetered). Losses from these systems are typically high, and...
Dentz, J. and Ansanelli, E. The Levy Partnership, Inc Systems Building Research Alliance
Apr 27, 2016
2 Resources
0 Stars
Publicly accessible
2 Resources
0 Stars
Publicly accessible