Search OEDI Data
Showing results 101 - 125 of 164.
Show
results per page.
Order by:
Available Now:
Research Areas
Accessibility
Data Type
Organization
Source
Snake River Plain Geothermal Play Fairway Analysis Volcanic Vents, Lacustrine Sediments, and post-Miocene Faults KMZ files
This dataset contain raw data files in kmz files (Google Earth georeference format). These files include volcanic vent locations and age, the distribution of fine-grained lacustrine sediments (which act as both a seal and an insulating layer for hydrothermal fluids), and post-Mioc...
Shervais, J. Utah State University
Oct 10, 2015
10 Resources
0 Stars
Publicly accessible
10 Resources
0 Stars
Publicly accessible
Fallon FORGE: Gravity and Magnetics Data
This package contains principal facts for new gravity data collected September November 2017 in support of the Fallon FORGE project. Also included are rock core density and magnetic susceptibility data for key core intervals, used in modeling 2D and 3D gravity inversions.
Indivi...
Blankenship, D. et al Sandia National Laboratories
Mar 09, 2018
4 Resources
0 Stars
Publicly accessible
4 Resources
0 Stars
Publicly accessible
Cornell Ithaca Campus heat use data for a model year
Hourly steam use data for all significant buildings from the fiscal year (FY) 2017 (1 July 2016 30 June 2017) are provided. The total annual campus heating load in FY 2017 was about 0.81 trillion Btu (283,000 MWth-hrs).
The data are presented as a spreadsheet, detailing on an ho...
Beyers, S. and Gustafson, J. Cornell University
Nov 13, 2019
2 Resources
0 Stars
Publicly accessible
2 Resources
0 Stars
Publicly accessible
The Performance House: A Cold Climate Challenge Home Old Greenwich
Working with builder partners on test homes allows for vetting of whole-house building strategies to eliminate any potential unintended consequences prior to implementing these solution packages on a production scale. To support this research, the Consortium for Advanced Residenti...
Williamson, J. et al Steven Winter Associates of the Consortium for Advanced Residential Buildings
Apr 27, 2016
4 Resources
0 Stars
Publicly accessible
4 Resources
0 Stars
Publicly accessible
Effectiveness of Shallow Temperature Surveys to Target a Geothermal Reservoir at Previously Explored Site at McGee Mountain, Nevada: Final Report for U.S. Department Of Energy Grant EE-0002830
The McGee Mountain geothermal area was selected to test early-stage shallow temperature survey techniques and drill two slim holes to test the resource. Geothermal Technical Partners, Inc. was able to complete only a small portion of the project before lack of funding prevented f...
Zehner, R. Geothermal Technical Partners, Inc.
Mar 07, 2014
1 Resources
0 Stars
Publicly accessible
1 Resources
0 Stars
Publicly accessible
Final Report Earth Source Heat: A Cascaded Systems Approach to DDU of Geothermal Energy on the Cornell Campus
The purpose of this document is to describe the contents contained within Geothermal Data Repository (GDR) node of the National Geothermal Data System (NGDS) that serves as the final report for the project "Earth Source Heat: A Cascaded Systems Approach to DDU of Geothermal Energy...
Tester, J. et al Cornell University
Oct 27, 2019
6 Resources
0 Stars
Publicly accessible
6 Resources
0 Stars
Publicly accessible
Model results and data for Nontechnical Barriers to Geothermal Development
Data included in this submission support the analysis conducted for the report "Nontechnical Barriers to Geothermal Development" which is linked bellow. These data include information about the power purchase agreements (PPAs) analyzed for the report, inputs and model results for ...
Rabinowitz, H. et al Pacific Northwest National Laboratory
Jul 25, 2022
4 Resources
0 Stars
Publicly accessible
4 Resources
0 Stars
Publicly accessible
Elevation Grid for top Columbia River Basalt (CRBG) in the Portland Basin used in DDU Feasibility Study
The Portland Basin is a prime location to assess the feasibility of DDU-TES because natural geologic conditions provide thermal and hydraulic separation from overlying aquifers that would otherwise sweep away stored heat. Under the Portland Basin, the lower Columbia River Basalt G...
Bershaw, J. and Scanlon, D. Portland State University
Dec 01, 2018
5 Resources
0 Stars
Publicly accessible
5 Resources
0 Stars
Publicly accessible
EGS Collab: Hydraulic Fracturing Test Measurements on the 4100L of SURF
This package includes data from two days of testing at the Sanford Underground Research Facility (SURF) on the 4100 level. The tests were performed in borehole TV4100 in the battery charging alcove south of the Yates shaft. TV4100 is a vertical borehole ~50 meters deep. A series o...
Ingraham, M. et al Sandia National Laboratories
Aug 15, 2019
3 Resources
0 Stars
Publicly accessible
3 Resources
0 Stars
Publicly accessible
National Brackish Groundwater Assessment 2017
Brackish groundwater (BGW), defined for this assessment as having a dissolved-solids concentration between 1,000 and 10,000 milligrams per liter, is an unconventional source of water that may offer a partial solution to current (2016) and future water challenges. In support of the...
Qi, S. and Harris, A. United States Geological Survey
Apr 05, 2017
3 Resources
0 Stars
Publicly accessible
3 Resources
0 Stars
Publicly accessible
Geothermal Resource at the McGee Mountain Prospect, Humboldt County, Nevada
This report describes the geothermal resource at McGee Mountain, including:
1. Local geology
2. Thermal features
3. Known boreholes and temperature gradients
4. Geophysical surveys
5. Fluid geochemistry and geothermometry
6. Estimate of the heat-in-place
Description of the heat-i...
Zehner, R. Geothermal Technical Partners, Inc.
Jul 01, 2010
1 Resources
0 Stars
Publicly accessible
1 Resources
0 Stars
Publicly accessible
Utah FORGE: Phase 1a Tensor Strainmeter Data for the April, 2022 Stimulation of Well 16A(78)-32
Data from two Tensor Optical Fiber Strainmeters that were operational during Stages 1, 2, and 3 of the April, 2022 stimulation of well 16A(78)-32. Each csv file contains data from each stimulation stage (stage1, stage2, stage3) for both Phase 1a strainmeter installations (FS01, f...
DeWolf, S. and Murdoch, L. Clemson University
Sep 15, 2022
8 Resources
0 Stars
Publicly accessible
8 Resources
0 Stars
Publicly accessible
G-Function Library for Modeling Vertical Bore Ground Heat Exchanger
This library contains g-functions (thermal response functions) for standard, regularly spaced vertical borehole ground heat exchangers. In total, it contains 34, 321 configurations. To permit interpolation, each configuration has g-functions for heights of 24, 48, 96, 192, and 384...
Spitler, J. et al Oak Ridge National Laboratory
Jun 30, 2021
10 Resources
0 Stars
Publicly accessible
10 Resources
0 Stars
Publicly accessible
Dixie Valley Engineered Geothermal System Exploration Methodology Project, Baseline Conceptual Model Report
The Engineered Geothermal System (EGS) Exploration Methodology Project is developing an exploration approach for EGS through the integration of geoscientific data. The overall project area is 2500km2 with the Calibration Area (Dixie Valley Geothermal Wellfield) being about 170km2....
Iovenitti, J. AltaRock Energy Inc
Jan 02, 2014
11 Resources
0 Stars
Publicly accessible
11 Resources
0 Stars
Publicly accessible
Slip and Dilation Tendency Analysis of McGinness Hills Geothermal Area
Slip and Dilation Tendency in focus areas
Critically stressed fault segments have a relatively high likelihood of acting as fluid flow conduits (Sibson, 1994). As such, the tendency of a fault segment to slip (slip tendency; Ts; Morris et al., 1996) or to dilate (dilation tendency...
E., J. University of Nevada
Dec 31, 2013
1 Resources
0 Stars
Publicly accessible
1 Resources
0 Stars
Publicly accessible
Greenbelt Homes Pilot Program: Summary of Building Envelope Retrofits, Planned HVAC Equipment Upgrades, and Energy Savings
In fall 2010, Greenbelt Homes, Inc. (GHI) a 1,566-home cooperative of circa 1930-1940 homes in Greenbelt, Maryland, undertook a multiyear pilot energy efficiency retrofit project. GHI established this pilot project as a basis for decision making for the rollout of a decade-long co...
Mallay, D. et al Home Innovation Research Labs National Association of Home Builders
Jul 21, 2016
4 Resources
0 Stars
Publicly accessible
4 Resources
0 Stars
Publicly accessible
Ocean Thermal Energy Conversion (OTEC) Net Power (Summer Average)
This shapefile represents seasonal summer average net power estimates.
The OTEC Plant model predicts the net power production at a specific location, given three inputs: surface temperature (°C), depth (m), and difference between warm surface water temperature and cold deep se...
Langle, N. and Laboratory, N. National Renewable Energy Laboratory
Nov 25, 2014
2 Resources
0 Stars
In curation
2 Resources
0 Stars
In curation
Ocean Thermal Energy Conversion (OTEC) Net Power (Winter Average)
This shapefile represents seasonal winter average net power estimates.
The OTEC Plant model predicts the net power production at a specific location, given three inputs: surface temperature (°C), depth (m), and difference between warm surface water temperature and cold deep se...
Langle, N. and Laboratory, N. National Renewable Energy Laboratory
Nov 25, 2014
2 Resources
0 Stars
In curation
2 Resources
0 Stars
In curation
Ocean Thermal Energy Conversion (OTEC) | Seawater Cooling Depth Profile 14ºC (Annual Average)
This shapefile represents the annual average depth profile to reach water at a temperature of 14ºC.
Sea water cooling can be used for industrial or residential cooling needs where heat must be rejected. A typical resource for direct air-conditioning applications is no warmer t...
Langle, N. and Laboratory, N. National Renewable Energy Laboratory
Nov 25, 2014
2 Resources
0 Stars
In curation
2 Resources
0 Stars
In curation
Ocean Thermal Energy Conversion (OTEC) | Seawater Cooling Depth Profile 14ºC (Summer Average)
This shapefile represents the seasonal summer depth profile to reach water at a temperature of 14ºC.
Sea water cooling can be used for industrial or residential cooling needs where heat must be rejected. A typical resource for direct air-conditioning applications is no warmer ...
Langle, N. and Laboratory, N. National Renewable Energy Laboratory
Nov 25, 2014
2 Resources
0 Stars
In curation
2 Resources
0 Stars
In curation
Ocean Thermal Energy Conversion (OTEC) | Seawater Cooling Depth Profile 14ºC (Winter Average)
This shapefile represents the seasonal winter depth profile to reach water at a temperature of 14ºC.
Sea water cooling can be used for industrial or residential cooling needs where heat must be rejected. A typical resource for direct air-conditioning applications is no warmer ...
Langle, N. and Laboratory, N. National Renewable Energy Laboratory
Nov 25, 2014
2 Resources
0 Stars
In curation
2 Resources
0 Stars
In curation
Ocean Thermal Energy Conversion (OTEC) | Seawater Cooling Depth Profile 20ºC (Annual Average)
This shapefile represents the annual average depth profile to reach water at a temperature of 20ºC.
Sea water cooling can be used for industrial or residential cooling needs where heat must be rejected. A typical resource for direct air-conditioning applications is no warmer t...
Langle, N. and Laboratory, N. National Renewable Energy Laboratory
Nov 25, 2014
2 Resources
0 Stars
In curation
2 Resources
0 Stars
In curation
Ocean Thermal Energy Conversion (OTEC) | Seawater Cooling Depth Profile 20ºC (Summer Average)
This shapefile represents the seasonal summer depth profile to reach water at a temperature of 20ºC.
Sea water cooling can be used for industrial or residential cooling needs where heat must be rejected. A typical resource for direct air-conditioning applications is no warmer ...
Langle, N. and Laboratory, N. National Renewable Energy Laboratory
Nov 25, 2014
2 Resources
0 Stars
In curation
2 Resources
0 Stars
In curation
Ocean Thermal Energy Conversion (OTEC) | Seawater Cooling Depth Profile 20ºC (Winter Average)
This shapefile represents the seasonal winter depth profile to reach water at a temperature of 20ºC.
Sea water cooling can be used for industrial or residential cooling needs where heat must be rejected. A typical resource for direct air-conditioning applications is no warmer ...
Langle, N. and Laboratory, N. National Renewable Energy Laboratory
Nov 25, 2014
2 Resources
0 Stars
In curation
2 Resources
0 Stars
In curation
Ocean Thermal Energy Conversion (OTEC) | Seawater Cooling Depth Profile 8ºC (Annual Average)
This shapefile represents the annual average depth profile to reach water at a temperature of 8ºC.
Sea water cooling can be used for industrial or residential cooling needs where heat must be rejected. A typical resource for direct air-conditioning applications is no warmer th...
Langle, N. and Laboratory, N. National Renewable Energy Laboratory
Nov 25, 2014
2 Resources
0 Stars
In curation
2 Resources
0 Stars
In curation