Search OEDI Data
Showing results 1 - 25 of 165.
Show
results per page.
Order by:
Available Now:
Research Areas
Accessibility
Data Type
Organization
Source
Curated Modeled Fault Data Set
The curated fault model simulation data set consists of tagged and fully-described time series representing simulated faults for the AFDD test building (ORNLs Flexible Research Platform (FRP)), including baseline performance, faulty performance, and corresponding energy impact. A ...
Kim, J. and Leach, M. National Renewable Energy Laboratory
Jun 24, 2019
7 Resources
0 Stars
Publicly accessible
7 Resources
0 Stars
Publicly accessible
Occupant Behavior in Commercial Buildings: Synthetic Population, Co-Simulation with EnergyPlus and Agent Based Modeling
This technical manual serves as an outline of three separate research projects related to building energy performance modeling of occupant behavior, conducted at the Rutgers Center for Green Building (RCGB): a Synthetic Population project, a Co-Simulation of Synthetic Population w...
Andrews, C. National Renewable Energy Laboratory
Apr 27, 2016
1 Resources
0 Stars
In curation
1 Resources
0 Stars
In curation
NREL Residential Buildings Group Partners
This spreadsheet contains a list of all the companies with which NREL's Residential Buildings Group has formed a partnership. The two types of partnership included in this spreadsheet are: Incubator and Test & Evaluation. This list was generated in April 7th, 2011.
### License...
Hallett, K. and Laboratory, N. National Renewable Energy Laboratory
Nov 25, 2014
2 Resources
0 Stars
In curation
2 Resources
0 Stars
In curation
Advancing Replicable Solutions for High-Performance Homes in the Southeast JMC Patrick Square
The work presented in this report advances the goals of the U.S. Department of Energy Building America program by improving the energy peformance of affordable and market-rate housing. Southface Energy Institute (Southface), part of the U.S. Department of Energy Building America r...
Sweet, M. et al Southface
Apr 27, 2016
3 Resources
0 Stars
Publicly accessible
3 Resources
0 Stars
Publicly accessible
EcoVillage: A Net Zero Energy Ready Community Ithaca Crawlspace
The U.S. Department of Energy's (DOE) Building America team, Consortium for Residential Buildings (CARB), is working with the EcoVillage cohousing community in Ithaca, New York, on the Third Residential EcoVillage Experience neighborhood. This community-scale project consists of 4...
Arena, L. et al Steven Winter Associates of the Consortium for Advanced Residential Buildings
Apr 27, 2016
3 Resources
0 Stars
Publicly accessible
3 Resources
0 Stars
Publicly accessible
Buildings Performance Database
The Buildings Performance Database (BPD) unlocks the power of building energy performance data. The platform enables users to perform statistical analysis on an anonymous dataset of tens of thousands of commercial and residential buildings from across the country. Users can compar...
Contact, B. and (EERE), O. Office of Energy Efficiency & Renewable Energy
Nov 25, 2014
2 Resources
0 Stars
In curation
2 Resources
0 Stars
In curation
ResStock: Annual Baseline Results with Component Loads
The ResStock Analysis Tool was developed by NREL with support from the U.S. Department of Energy to provide a new approach to large-scale residential analysis by combining large public and private data sources, statistical sampling, detailed sub hourly building simulations, and hi...
Speake, A. et al National Renewable Energy Lab
Mar 03, 2023
6 Resources
0 Stars
Publicly accessible
6 Resources
0 Stars
Publicly accessible
Simulated Load Profiles for DOE Commercial Reference Buildings (17 Years Using NSRDB Data)
This data set consists of simulated load profiles (1998-2014, 30 minute profile) for commercial customers using the Pacific Northwest National Laboratory residential prototype building models and the US Department of Energy's (DOE) commercial reference building models made for Ene...
Darghouth, N. Lawrence Berkeley National Laboratory
Sep 16, 2016
23 Resources
1 Stars
In curation
23 Resources
1 Stars
In curation
1D Heat Loss Models Validation Experiment
Contains data from the model validation in the 1D Heat Loss Models to Predict the Aquifer Temperature Profile during Hot/Cold Water Injection Project. The data include two COMSOL models (2D axisymmetric benchmark model and 2D Vinsome model), one python code (1D Vinsome based FEM n...
Chen, K. et al UC Berkeley
Jan 18, 2022
8 Resources
0 Stars
Publicly accessible
8 Resources
0 Stars
Publicly accessible
Commercial Reference Building: Supermarket
Commercial reference buildings provide complete descriptions for whole building energy analysis using EnergyPlus (see "About EnergyPlus" resource link) simulation software. Included here is data pertaining to the reference building type "Supermarket" for each of the 16 climate zon...
Deru, M. et al National Renewable Energy Laboratory
Nov 25, 2014
8 Resources
0 Stars
Publicly accessible
8 Resources
0 Stars
Publicly accessible
Commercial Reference Building: Warehouse
Commercial reference buildings provide complete descriptions for whole building energy analysis using EnergyPlus (see "About EnergyPlus" resource link) simulation software. Included here is data pertaining to the reference building type "Warehouse" for each of the 16 climate zones...
Deru, M. et al National Renewable Energy Laboratory
Nov 25, 2014
8 Resources
0 Stars
Publicly accessible
8 Resources
0 Stars
Publicly accessible
Commercial Reference Building: Midrise Apartment
Commercial reference buildings provide complete descriptions for whole building energy analysis using EnergyPlus (see "About EnergyPlus" resource link) simulation software. Included here is data pertaining to the reference building type "Midrise Apartment" for each of the 16 clima...
Deru, M. et al National Renewable Energy Laboratory
Nov 25, 2014
8 Resources
0 Stars
Publicly accessible
8 Resources
0 Stars
Publicly accessible
Commercial Reference Building: Secondary School
Commercial reference buildings provide complete descriptions for whole building energy analysis using EnergyPlus (see "About EnergyPlus" resource link) simulation software. Included here is data pertaining to the reference building type "Secondary School" for each of the 16 climat...
Deru, M. et al National Renewable Energy Laboratory
Nov 25, 2014
8 Resources
0 Stars
Publicly accessible
8 Resources
0 Stars
Publicly accessible
Commercial Reference Building: Primary School
Commercial reference buildings provide complete descriptions for whole building energy analysis using EnergyPlus (see "About EnergyPlus" resource link) simulation software. Included here is data pertaining to the reference building type "Primary School" for each of the 16 climate ...
Deru, M. et al National Renewable Energy Laboratory
Nov 25, 2014
8 Resources
0 Stars
Publicly accessible
8 Resources
0 Stars
Publicly accessible
Commercial Reference Building: Strip Mall
Commercial reference buildings provide complete descriptions for whole building energy analysis using EnergyPlus (see "About EnergyPlus" resource link) simulation software. Included here is data pertaining to the reference building type "Strip Mall" for each of the 16 climate zone...
Deru, M. et al National Renewable Energy Laboratory
Nov 25, 2014
8 Resources
0 Stars
Publicly accessible
8 Resources
0 Stars
Publicly accessible
Commercial Reference Building: Hospital
Commercial reference buildings provide complete descriptions for whole building energy analysis using EnergyPlus (see "About EnergyPlus" resource link) simulation software. Included here is data pertaining to the reference building type "Hospital" for each of the 16 climate zones ...
Deru, M. et al National Renewable Energy Laboratory
Nov 25, 2014
8 Resources
0 Stars
Publicly accessible
8 Resources
0 Stars
Publicly accessible
Commercial Reference Building: Outpatient Health Care
Commercial reference buildings provide complete descriptions for whole building energy analysis using EnergyPlus (see "About EnergyPlus" resource link) simulation software. Included here is data pertaining to the reference building type "Outpatient Health Care" for each of the 16 ...
Deru, M. et al National Renewable Energy Laboratory
Nov 25, 2014
8 Resources
0 Stars
Publicly accessible
8 Resources
0 Stars
Publicly accessible
Commercial Reference Building: Quick Service Restaurant
Commercial reference buildings provide complete descriptions for whole building energy analysis using EnergyPlus (see "About EnergyPlus" resource link) simulation software. Included here is data pertaining to the reference building type "Quick Service Restaurant" for each of the 1...
Deru, M. et al National Renewable Energy Laboratory
Nov 25, 2014
8 Resources
0 Stars
Publicly accessible
8 Resources
0 Stars
Publicly accessible
Commercial Reference Building: Large Hotel
Commercial reference buildings provide complete descriptions for whole building energy analysis using EnergyPlus (see "About EnergyPlus" resource link) simulation software. Included here is data pertaining to the reference building type "Large Hotel" for each of the 16 climate zon...
Deru, M. et al National Renewable Energy Laboratory
Nov 25, 2014
8 Resources
0 Stars
Publicly accessible
8 Resources
0 Stars
Publicly accessible
Commercial Reference Building: Large Office
Commercial reference buildings provide complete descriptions for whole building energy analysis using EnergyPlus (see "About EnergyPlus" resource link) simulation software. Included here is data pertaining to the reference building type "Large Office" for each of the 16 climate zo...
Deru, M. et al National Renewable Energy Laboratory
Nov 25, 2014
8 Resources
0 Stars
Publicly accessible
8 Resources
0 Stars
Publicly accessible
Commercial Reference Building: Stand-alone Retail
Commercial reference buildings provide complete descriptions for whole building energy analysis using EnergyPlus (see "About EnergyPlus" resource link) simulation software. Included here is data pertaining to the reference building type "Stand-alone Retail" for each of the 16 clim...
Deru, M. et al National Renewable Energy Laboratory
Nov 25, 2014
8 Resources
0 Stars
Publicly accessible
8 Resources
0 Stars
Publicly accessible
Commercial Reference Building: Full Service Restaurant
Commercial reference buildings provide complete descriptions for whole building energy analysis using EnergyPlus (see "About EnergyPlus" resource link) simulation software. Included here is data pertaining to the reference building type "Full Service Restaurant" for each of the 16...
Deru, M. et al National Renewable Energy Laboratory
Nov 25, 2014
8 Resources
0 Stars
Publicly accessible
8 Resources
0 Stars
Publicly accessible
Commercial Reference Building: Medium Office
Commercial reference buildings provide complete descriptions for whole building energy analysis using EnergyPlus (see "About EnergyPlus" resource link) simulation software. Included here is data pertaining to the reference building type "Medium Office" for each of the 16 climate z...
Deru, M. et al National Renewable Energy Laboratory
Nov 25, 2014
8 Resources
0 Stars
Publicly accessible
8 Resources
0 Stars
Publicly accessible
Commercial Reference Building: Small Hotel
Commercial reference buildings provide complete descriptions for whole building energy analysis using EnergyPlus (see "About EnergyPlus" resource link) simulation software. Included here is data pertaining to the reference building type "Small Hotel" for each of the 16 climate zon...
Deru, M. et al National Renewable Energy Laboratory
Nov 25, 2014
8 Resources
0 Stars
Publicly accessible
8 Resources
0 Stars
Publicly accessible
The Performance House: A Cold Climate Challenge Home Old Greenwich
Working with builder partners on test homes allows for vetting of whole-house building strategies to eliminate any potential unintended consequences prior to implementing these solution packages on a production scale. To support this research, the Consortium for Advanced Residenti...
Williamson, J. et al Steven Winter Associates of the Consortium for Advanced Residential Buildings
Apr 27, 2016
4 Resources
0 Stars
Publicly accessible
4 Resources
0 Stars
Publicly accessible