Search OEDI Data
Showing results 1 - 9 of 9.
Show
results per page.
Order by:
Available Now:
Research Areas
Accessibility
Data Type
Organization
Source
Shaker Test Results Comparing Rare Earth Element Sorption Between Natural and Doped Simulated Geothermal Brine
Shaker test data comparing rare earth element (REE) sorption onto Tusaar media between one natural geothermal brine and two simulated brines doped with known mineral concentrations.
Stull, D. Tusaar Corp.
May 24, 2016
1 Resources
0 Stars
Publicly accessible
1 Resources
0 Stars
Publicly accessible
Microcosm Shaker Test for Determining the Amount of Ligand Bleed from Media #1 at Various Temperatures and pH's
This PDF outlines the experiments for determining the amount of ligand bleed from our Media #1 at various temperatures and pH's.
Garland, G. Tusaar Corp.
Sep 18, 2015
1 Resources
0 Stars
Publicly accessible
1 Resources
0 Stars
Publicly accessible
Rare Earth Element Sorption Study on sieved 50 +100 mesh fraction of Media 1 in Brine 1 with Different Starting pHs at 70C
This is a continuation of the rare earth element sorption study for shaker bath tests on 2g media #1 in 150mL brine #1 with different starting pH's at 70C. In a previous submission we reported data for shaker bath tests for brine #1 with starting pH's of 3.5, 4.5 and 5.5. In this ...
Garland, G. Tusaar Corp.
Sep 29, 2015
5 Resources
0 Stars
Publicly accessible
5 Resources
0 Stars
Publicly accessible
Shaker Table Experiments with Rare Earth Elements Sorption from Geothermal Brine
This dataset described shaker table experiments ran with sieved 50 +100 mesh media #1 in brine #1 that have 2ppm each of the 7 REE metals at different starting pH's of 3.5, 4.5, and 5.5. The experimental conditions are 2g media to 150mL of REE solution, at 70C.
Garland, G. Tusaar Corp.
Jul 21, 2015
4 Resources
0 Stars
Publicly accessible
4 Resources
0 Stars
Publicly accessible
REE Sorption Study of Seived 50 +100 Mesh Fraction of Media 1 in Brine 1 at Different Concentrations of REE at 70C
This dataset shows the sorption capacities of smaller grain size (-50 +100 mesh) of media #1 in brine #1 at different starting concentrations of REE's at elevated temperature of 70C. The experimental conditions are 2g of 50 +100 mesh media #1 to 150mL of REE solution at concentrat...
Garland, G. Tusaar Corp.
Jun 29, 2015
4 Resources
0 Stars
Publicly accessible
4 Resources
0 Stars
Publicly accessible
Dynamic Column Extraction for Europium on Media 1 at Ambient Temperature
This is a dataset for a 200ppm europium solution sent through a column with 12g of media #1 at pH of 3.2. This column experiment was run at ambient temperature at a flow rate of 2mL/min.
Garland, G. Tusaar Corp.
Apr 07, 2015
2 Resources
0 Stars
Publicly accessible
2 Resources
0 Stars
Publicly accessible
Sorption Capacity of Europium for Media 1 and Media 2 from Solution at Ambient Temperature
This dataset shows the capacity for Europium of media #1 and media #2 in a shakertable experiment. The experimental conditions were 150mL of 500ppm Eu solution, 2g of media, pH of 3.2, at ambient temperature.
Garland, G. Tusaar Corp.
Mar 16, 2015
2 Resources
0 Stars
Publicly accessible
2 Resources
0 Stars
Publicly accessible
Repetitive Regeneration of Media 1 after REE Sorption from Brine 1 at 70C
This dataset shows the ability of media #1 to be loaded with REE's, stripped of the REE's sequestered, regenerated, and reused over many cycles.
Garland, G. Tusaar Corp.
Jul 23, 2015
3 Resources
0 Stars
Publicly accessible
3 Resources
0 Stars
Publicly accessible
REE Sorption Study for Media #1 and Media #2 in Brine #1 and #2 at different Liquid to Solid Ratio's at Ambient Temperature
This data set shows the different loading capacities of Media #1 and Media #2 in a high and low salt content brine matrix at different liquid to solid ratio's. These data sets are shaker bath tests on media #1 and media #2 in brine's #1 and #2 at 500mL-.5g(1000-1 ratio), 150mL-.75...
Garland, G. Tusaar Corp.
Mar 27, 2015
9 Resources
0 Stars
Publicly accessible
9 Resources
0 Stars
Publicly accessible