Search OEDI Data
Showing results 51 - 75 of 118.
Show
results per page.
Order by:
Available Now:
Research Areas
Accessibility
Data Type
Organization
Source
University of Illinois Campus Deep Direct-Use Feasibility Study Subsurface Temperature Profile
High resolution fiber-optic distributed temperature sensing logs from the Illinois Basin Decatur Project (IBDP) in Decatur, IL were used to model the thermal profile in the Illinois Basin.
Lin, Y. et al University of Illinois
Jun 13, 2018
5 Resources
0 Stars
Publicly accessible
5 Resources
0 Stars
Publicly accessible
Ocean Thermal Energy Conversion (OTEC) Cold Water Depth (Annual Average)
This shapefile represents annual average cold water depth recordings.
The cold water is defined by locating the depth that leads to the greatest average annual net power at each location when depth and its corresponding ?T are input into the power equation. This optimization ba...
Langle, N. and Laboratory, N. National Renewable Energy Laboratory
Nov 25, 2014
2 Resources
0 Stars
In curation
2 Resources
0 Stars
In curation
Ocean Thermal Energy Conversion (OTEC) Cold Water Depth (Summer Average)
This shapefile represents seasonal summer average cold water depth recordings.
The cold water is defined by locating the depth that leads to the greatest average annual net power at each location when depth and its corresponding ΔT are input into the power equation. This optim...
Langle, N. and Laboratory, N. National Renewable Energy Laboratory
Nov 25, 2014
2 Resources
0 Stars
In curation
2 Resources
0 Stars
In curation
Ocean Thermal Energy Conversion (OTEC) Cold Water Depth (Winter Average)
This shapefile represents seasonal winter average cold water depth recordings.
The cold water is defined by locating the depth that leads to the greatest average annual net power at each location when depth and its corresponding ΔT are input into the power equation. This optim...
Langle, N. and Laboratory, N. National Renewable Energy Laboratory
Nov 25, 2014
2 Resources
0 Stars
In curation
2 Resources
0 Stars
In curation
Ocean Thermal Energy Conversion (OTEC) delta T (Annual Average)
This shapefile represents annual average delta T estimates.
ΔT represents the difference in temperature (°C) between the warm and cold water sources used by an OTEC plant at a specific location. Warm water is defined uniformly as water at a depth of 20 m, while cold water is ...
Langle, N. and Laboratory, N. National Renewable Energy Laboratory
Nov 25, 2014
2 Resources
0 Stars
In curation
2 Resources
0 Stars
In curation
Ocean Thermal Energy Conversion (OTEC) delta T (Summer Average)
This shapefile represents seasonal summer average delta T estimates.
ΔT represents the difference in temperature (°C) between the warm and cold water sources used by an OTEC plant at a specific location. Warm water is defined uniformly as water at a depth of 20 m, while cold ...
Langle, N. and Laboratory, N. National Renewable Energy Laboratory
Nov 25, 2014
2 Resources
0 Stars
In curation
2 Resources
0 Stars
In curation
Ocean Thermal Energy Conversion (OTEC) Net Power (Summer Average)
This shapefile represents seasonal summer average net power estimates.
The OTEC Plant model predicts the net power production at a specific location, given three inputs: surface temperature (°C), depth (m), and difference between warm surface water temperature and cold deep se...
Langle, N. and Laboratory, N. National Renewable Energy Laboratory
Nov 25, 2014
2 Resources
0 Stars
In curation
2 Resources
0 Stars
In curation
Ocean Thermal Energy Conversion (OTEC) Net Power (Winter Average)
This shapefile represents seasonal winter average net power estimates.
The OTEC Plant model predicts the net power production at a specific location, given three inputs: surface temperature (°C), depth (m), and difference between warm surface water temperature and cold deep se...
Langle, N. and Laboratory, N. National Renewable Energy Laboratory
Nov 25, 2014
2 Resources
0 Stars
In curation
2 Resources
0 Stars
In curation
Ocean Thermal Energy Conversion (OTEC) | Seawater Cooling Depth Profile 14ºC (Annual Average)
This shapefile represents the annual average depth profile to reach water at a temperature of 14ºC.
Sea water cooling can be used for industrial or residential cooling needs where heat must be rejected. A typical resource for direct air-conditioning applications is no warmer t...
Langle, N. and Laboratory, N. National Renewable Energy Laboratory
Nov 25, 2014
2 Resources
0 Stars
In curation
2 Resources
0 Stars
In curation
Ocean Thermal Energy Conversion (OTEC) | Seawater Cooling Depth Profile 14ºC (Summer Average)
This shapefile represents the seasonal summer depth profile to reach water at a temperature of 14ºC.
Sea water cooling can be used for industrial or residential cooling needs where heat must be rejected. A typical resource for direct air-conditioning applications is no warmer ...
Langle, N. and Laboratory, N. National Renewable Energy Laboratory
Nov 25, 2014
2 Resources
0 Stars
In curation
2 Resources
0 Stars
In curation
Ocean Thermal Energy Conversion (OTEC) | Seawater Cooling Depth Profile 14ºC (Winter Average)
This shapefile represents the seasonal winter depth profile to reach water at a temperature of 14ºC.
Sea water cooling can be used for industrial or residential cooling needs where heat must be rejected. A typical resource for direct air-conditioning applications is no warmer ...
Langle, N. and Laboratory, N. National Renewable Energy Laboratory
Nov 25, 2014
2 Resources
0 Stars
In curation
2 Resources
0 Stars
In curation
Ocean Thermal Energy Conversion (OTEC) | Seawater Cooling Depth Profile 20ºC (Annual Average)
This shapefile represents the annual average depth profile to reach water at a temperature of 20ºC.
Sea water cooling can be used for industrial or residential cooling needs where heat must be rejected. A typical resource for direct air-conditioning applications is no warmer t...
Langle, N. and Laboratory, N. National Renewable Energy Laboratory
Nov 25, 2014
2 Resources
0 Stars
In curation
2 Resources
0 Stars
In curation
Ocean Thermal Energy Conversion (OTEC) | Seawater Cooling Depth Profile 20ºC (Summer Average)
This shapefile represents the seasonal summer depth profile to reach water at a temperature of 20ºC.
Sea water cooling can be used for industrial or residential cooling needs where heat must be rejected. A typical resource for direct air-conditioning applications is no warmer ...
Langle, N. and Laboratory, N. National Renewable Energy Laboratory
Nov 25, 2014
2 Resources
0 Stars
In curation
2 Resources
0 Stars
In curation
Ocean Thermal Energy Conversion (OTEC) | Seawater Cooling Depth Profile 20ºC (Winter Average)
This shapefile represents the seasonal winter depth profile to reach water at a temperature of 20ºC.
Sea water cooling can be used for industrial or residential cooling needs where heat must be rejected. A typical resource for direct air-conditioning applications is no warmer ...
Langle, N. and Laboratory, N. National Renewable Energy Laboratory
Nov 25, 2014
2 Resources
0 Stars
In curation
2 Resources
0 Stars
In curation
Ocean Thermal Energy Conversion (OTEC) | Seawater Cooling Depth Profile 8ºC (Annual Average)
This shapefile represents the annual average depth profile to reach water at a temperature of 8ºC.
Sea water cooling can be used for industrial or residential cooling needs where heat must be rejected. A typical resource for direct air-conditioning applications is no warmer th...
Langle, N. and Laboratory, N. National Renewable Energy Laboratory
Nov 25, 2014
2 Resources
0 Stars
In curation
2 Resources
0 Stars
In curation
Ocean Thermal Energy Conversion (OTEC) | Seawater Cooling Depth Profile 8ºC (Summer Average)
This shapefile represents the seasonal summer depth profile to reach water at a temperature of 8ºC.
Sea water cooling can be used for industrial or residential cooling needs where heat must be rejected. A typical resource for direct air-conditioning applications is no warmer t...
Langle, N. and Laboratory, N. National Renewable Energy Laboratory
Nov 25, 2014
2 Resources
0 Stars
In curation
2 Resources
0 Stars
In curation
Ocean Thermal Energy Conversion (OTEC) | Seawater Cooling Depth Profile 8ºC (Winter Average)
This shapefile represents the seasonal winter depth profile to reach water at a temperature of 8ºC.
Sea water cooling can be used for industrial or residential cooling needs where heat must be rejected. A typical resource for direct air-conditioning applications is no warmer t...
Langle, N. and Laboratory, N. National Renewable Energy Laboratory
Nov 25, 2014
2 Resources
0 Stars
In curation
2 Resources
0 Stars
In curation
ResStock: Annual Baseline Results with Component Loads
The ResStock Analysis Tool was developed by NREL with support from the U.S. Department of Energy to provide a new approach to large-scale residential analysis by combining large public and private data sources, statistical sampling, detailed sub hourly building simulations, and hi...
Speake, A. et al National Renewable Energy Lab
Mar 03, 2023
6 Resources
0 Stars
Curated
6 Resources
0 Stars
Curated
University of Illinois Campus Deep Direct-Use Feasibility Study Chemistry of Formation Waters
Studies of chemical composition of natural brines from rock formations in the Illinois Basin as part of the University of Illinois deep direct-use feasibility study.
Lin, Y. et al University of Illinois
Apr 23, 2018
6 Resources
0 Stars
Publicly accessible
6 Resources
0 Stars
Publicly accessible
Transient Cold-Climate Building Foundation Hygrothermal Experimental Data
The data consist of two years of continuous transient experimental measurements on the hygrothermal performance of concrete masonry block walls in a full basement in a cold climate (US DOE climate zone 7). The walls were insulated in compliance with the thermal requirements of the...
Merket, N. and Laboratory, N. National Renewable Energy Laboratory
Jun 30, 2015
4 Resources
0 Stars
In curation
4 Resources
0 Stars
In curation
Ocean Thermal Energy Conversion (OTEC) Net Power (Annual Average)
This shapefile represents annual average net power estimates.
The OTEC Plant model predicts the net power production at a specific location, given three inputs: surface temperature (°C), depth (m), and difference between warm surface water temperature and cold deep sea water t...
Langle, N. and Laboratory, N. National Renewable Energy Laboratory
Nov 25, 2014
2 Resources
0 Stars
In curation
2 Resources
0 Stars
In curation
McGee Mountain Shallow (2m) Temperature Survey, Humboldt County, Nevada 2009
This shapefile contains location and attribute data for a shallow (2 meter) temperature survey conducted by Geothermal Technical Partners, Inc. during late 2008 and early 2009. Temperatures at 2m depth were measured at 192 separate points as outlined by Coolbaugh et al., 2007. The...
Zehner, R. Geothermal Technical Partners, Inc.
Jan 01, 2009
2 Resources
0 Stars
Publicly accessible
2 Resources
0 Stars
Publicly accessible
Electricity Net Generation From Renewable Energy by Energy Use Sector and Energy Source, 2004 2008
Provides annual net electricity generation (thousand kilowatt-hours) from renewable energy in the United States by energy use sector (commercial, industrial, electric power) and by energy source (e.g. biomas, solar thermal/pv).
Hallett, K. and Laboratory, N. National Renewable Energy Laboratory
Nov 25, 2014
2 Resources
0 Stars
In curation
2 Resources
0 Stars
In curation
Analysis of Geothermal Resources in Three Texas Counties
This project updates the geothermal resources beneath our oil and gas fields, as part of the research for the Texas GEO project. This report "Analysis of Geothermal Resources in Three Texas Counties" (October 2020) improves on previous mapping of the Texas resources for the counti...
Richards, M. and Batir, J. Southern Methodist University Huffington Department of Earth Sciences
Oct 30, 2020
3 Resources
0 Stars
Publicly accessible
3 Resources
0 Stars
Publicly accessible
Cornell Ithaca Campus heat use data for a model year
Hourly steam use data for all significant buildings from the fiscal year (FY) 2017 (1 July 2016 30 June 2017) are provided. The total annual campus heating load in FY 2017 was about 0.81 trillion Btu (283,000 MWth-hrs).
The data are presented as a spreadsheet, detailing on an ho...
Beyers, S. and Gustafson, J. Cornell University
Nov 13, 2019
2 Resources
0 Stars
Publicly accessible
2 Resources
0 Stars
Publicly accessible