Search OEDI Data
Showing results 1 - 25 of 52.
Show
results per page.
Order by:
Available Now:
Research Areas
Accessibility
Data Type
Organization
Source
Excavationless Exterior Foundation Insulation Field Study Minnesota
Building science research supports installing exterior (soil side) foundation insulation as the optimal method to enhance the hygrothermal performance of new homes. With exterior foundation insulation, water management strategies are maximized while insulating the basement space a...
Jacobson, R. et al University of Minnesota NorthernSTAR Building America Partnership
Apr 27, 2016
11 Resources
0 Stars
In curation
11 Resources
0 Stars
In curation
NorthernSTAR 1.5-Story Demonstration House of Cold Climate Solutions for Affordable Housing
This is a NorthernSTAR renovation project for Urban Homeworks incorporating installation of a combination space and water heater, Overcoat insulation retrofit on the roof, and Excavationless foundation insulation retrofit.
STRUCTURE 1401 North 16th Ave Minneapolis, MN 55411
Var...
Jacobson, R. et al University of Minnesota NorthernSTAR Building America Partnership
Apr 27, 2016
12 Resources
0 Stars
In curation
12 Resources
0 Stars
In curation
Spray Foam Exterior Insulation with Stand-Off Furring New York
IBACOS and Green Homes America 1 (GHA) collaborated with the New York State Energy Research and Development Authority (NYSERDA) Advanced Buildings Program to research a variation of a commercial curtain wall assembly for residential construction as part of a comprehensive whole-ho...
Rapport, A. et al Ibacos Innovation
Apr 27, 2016
2 Resources
0 Stars
In curation
2 Resources
0 Stars
In curation
New York State Energy Research and Development Authority Exterior Building Solutions To Insulation
TO4 8.2.2: Space Cond. for Deep Energy Retrofits
The purpose of this project for the New York State Energy Research and Development Authority (NYSERDA) is to find new or improved strategies for exterior building solutions in regard to insulation that will provide extensive energy...
Beach, R. et al Ibacos Innovation
Apr 27, 2016
14 Resources
0 Stars
In curation
14 Resources
0 Stars
In curation
Evaluating an Exterior Insulation and Finish System for Deep Energy Retrofits
This report provides a case study of a deep energy retrofit using a site-applied exterior insulation and finish system (EIFS). Prefabricated EIFS panels are also discussed as a potential wall insulation retrofit solution. EIFSs are common in new and retrofit commercial constructio...
Dentz, J. and Podorson, D. The Levy Partnership, Inc Systems Building Research Alliance
Apr 27, 2016
2 Resources
0 Stars
In curation
2 Resources
0 Stars
In curation
Measure Guideline: Deep Energy Enclosure Retrofit for Interior Insulation of Masonry Walls and Flat Roofs
Measure Guideline: Deep Energy Enclosure Retrofit for Zero Energy Ready House Flat Roofs
BSC TO5 Task 7.4 Deep Energy Enclosure Retrofit (DEER) for Interior Insulation of Masonry Walls
Lawrence, MA 01840
This Measure Guideline describes a deep energy enclosure retrofit solution ...
Musunuru, S. et al Building Science Corporation
Apr 27, 2016
5 Resources
0 Stars
In curation
5 Resources
0 Stars
In curation
Nstar Project Overcoat: Exterior Insulation Strategies for 1.5-Story Roof Applications in Cold Climates
This is a repository for all NorthernSTAR Overcoat insulation retrofit projects. Both houses received Overcoat insulation retrofit on roof only, performed by Cocoon Insulation.
1 St. Louis Park house St. Louis Park, MN
2 Edina house Edina, MN
Many approaches to ice dam mitigatio...
Jacobson, R. et al University of Minnesota NorthernSTAR Building America Partnership
Apr 27, 2016
10 Resources
0 Stars
In curation
10 Resources
0 Stars
In curation
Transient Cold-Climate Building Foundation Hygrothermal Experimental Data
The data consist of two years of continuous transient experimental measurements on the hygrothermal performance of concrete masonry block walls in a full basement in a cold climate (US DOE climate zone 7). The walls were insulated in compliance with the thermal requirements of the...
Merket, N. and Laboratory, N. National Renewable Energy Laboratory
Jun 30, 2015
4 Resources
0 Stars
In curation
4 Resources
0 Stars
In curation
Monitoring of Double-Stud Wall Moisture Conditions in the Northeast
BSC TO5 Task 2.2 Monitoring of Double Stud Wall Moisture Conditions in the Northeast
Field test data available for wood moisture contents, temperature, and relative humidity.
STRUCTURE House Devens, MA 01432
Three double-stud assemblies were compared: 12-in. ocSPF, 12-in. cellulo...
Ueno, K. Building Science Corporation
Apr 27, 2016
2 Resources
0 Stars
In curation
2 Resources
0 Stars
In curation
Mass Customization of Prefabricated Panel Blocks for Deep Wall Insulation Retrofits
The project this data comes from looks to make building wall retrofits less expensive and easier to install by using exterior insulating panels. This is done to make buildings more energy efficient without expensive wall retrofits or reconstruction. The "Measurement and Verificati...
Sharon, A. et al Fraunhofer Center for Manufacturing Innovation CMI
Dec 14, 2021
2 Resources
0 Stars
Publicly accessible
2 Resources
0 Stars
Publicly accessible
Innovative Technologies to Overcome Interface Challenges for Wall Retrofit Systems
In this project, we will develop a system of computer-assisted, automated workflows to specify, manufacture, and install panelized retrofit systems, focusing particularly on panel joints and interface detailing between the panels and facade openings. The proposed system will subst...
Harris, C. et al National Renewable Energy Laboratory (NREL)
Dec 13, 2021
3 Resources
0 Stars
Publicly accessible
3 Resources
0 Stars
Publicly accessible
Modular Zero Energy Ready Homes: Bright Built Maine
Kaplan Thompson Architects (KTA) has specialized in sustainable, energy-efficient buildings, and they have designed several custom, zero-energy homes in New England. These zero-energy projects have generally been high-end, custom homes with budgets that could accommodate advanced ...
Aldrich, R. and Butterfield, K. Steven Winter Associates of the Consortium for Advanced Residential Buildings
Apr 27, 2016
2 Resources
0 Stars
In curation
2 Resources
0 Stars
In curation
Field Testing Unvented Roofs with Asphalt Shingles in Cold and Hot-humid Climates
BSC TO5 Task 7.1 Field Testing Unvented Roofs with Asphalt Shingles in Cold Climates Bolingbrook, IL 60440
BSC TO5 Task 7.1 Field Testing Unvented Roofs with Asphalt Shingles in Hot-Humid Climates Friendswood, TX 77546
To understand the long-term moisture performance of unvented ...
Ueno, K. and Lstiburek, J. Building Science Corporation
Apr 27, 2016
3 Resources
0 Stars
In curation
3 Resources
0 Stars
In curation
Verdant Power Gen5 KHPS and TriFrame System Content Models
This submission includes the Component Content Model for Verdant Power TriFrame and the System Content Model for Verdant Power TriFrame + 3 Gen5 KHPS Turbines. The TriFrame is the foundation component of the system, which consists of a TriFrame + 3 Gen5 KHPS Turbines (TF+3T).
Corren, D. et al Verdant Power Inc.
Jul 05, 2018
2 Resources
0 Stars
Publicly accessible
2 Resources
0 Stars
Publicly accessible
Evaluation of Crawlspace Retrofits in Multifamily Buildings
The existing condition was a vented crawlspace with an uninsulated floor between the crawlspace and the dwelling units above. The crawlspace was therefore a critically weak link in the building enclosure and was ripe for improvement. Saving energy was the primary interest and goal...
Rudd, A. Advanced Building Systems
Apr 27, 2016
41 Resources
0 Stars
In curation
41 Resources
0 Stars
In curation
Estimates of Home Insulation Levels in Great Britain
The UK Department of Energy and Climate Change (DECC) publishes quarterly estimates of the number of homes in Great Britain with loft and cavity wall insulation. The estimates are released as an indication of the adoption of energy efficiency measures in Great Britain. Quarterly d...
Hallett, K. and (DECC), U. National Renewable Energy Laboratory
Dec 14, 2010
2 Resources
0 Stars
In curation
2 Resources
0 Stars
In curation
M3 Wave DMP/APEX WEC Projected LCOE
Projected LCOE model for the Delos-Reyes Morrow Pressure Device (DMP), commercialized by M3 Wave LLC as "APEX," based on information gained during project performance.
Morrow, M. and Delos-Reyes, M. M3 Wave
Aug 01, 2018
1 Resources
0 Stars
Publicly accessible
1 Resources
0 Stars
Publicly accessible
Field Testing of Compartmentalization Methods for Multifamily Construction Washington DC
BSC TO5 Task 2.1 Field Testing of Compartmentalization Methods for Multifamily Construction Capitol Heights, MD 20743
A building comprising five vertical townhome units was built in the Washington, D.C., area; the townhomes were three-story slab-on-grade units (1700-2000 ft2) wit...
Ueno, K. and Lstiburek, J. Building Science Corporation
Apr 27, 2016
22 Resources
0 Stars
In curation
22 Resources
0 Stars
In curation
The Performance House: A Cold Climate Challenge Home Old Greenwich
Working with builder partners on test homes allows for vetting of whole-house building strategies to eliminate any potential unintended consequences prior to implementing these solution packages on a production scale. To support this research, the Consortium for Advanced Residenti...
Williamson, J. et al Steven Winter Associates of the Consortium for Advanced Residential Buildings
Apr 27, 2016
4 Resources
0 Stars
In curation
4 Resources
0 Stars
In curation
Field Testing of an Unvented Roof with Fibrous Insulation, Tiles, and Vapor Diffusion Venting
BSC TO5 Task 2.5 Field Testing of an Unvented Roof with Fibrous Insulation and Tiles Winter Park, FL 32789
Field test data available for wood moisture contents, temperature, and relative humidity.
Unvented roofs (aka cathedralized attics) are an established presence in Florida re...
Ueno, K. and Lstiburek, J. Building Science Corporation
Apr 27, 2016
2 Resources
0 Stars
In curation
2 Resources
0 Stars
In curation
Utah FORGE Well 16A(78)-32 Core Photos
Images of core samples collected from Utah FORGE well 16A(78)-32. These images were created by stitching together multiple photographs resulting in a circumferential view of the cores exterior in two dimensions. Core footages (measured depths) are indicated in the file names, and ...
Jones, C. Energy and Geoscience Institute at the University of Utah
Aug 11, 2021
1 Resources
0 Stars
Publicly accessible
1 Resources
0 Stars
Publicly accessible
Commercial and Residential Hourly Load Profiles for all TMY3 Locations in the United States
Note: This dataset has been superseded by the dataset found at "End-Use Load Profiles for the U.S. Building Stock" (submission 4520; linked in the submission resources), which is a comprehensive and validated representation of hourly load profiles in the U.S. commercial and reside...
Ong, S. and Clark, N. National Renewable Energy Laboratory
Nov 25, 2014
22 Resources
0 Stars
Publicly accessible
22 Resources
0 Stars
Publicly accessible
Greenbelt Homes Pilot Program: Summary of Building Envelope Retrofits, Planned HVAC Equipment Upgrades, and Energy Savings
In fall 2010, Greenbelt Homes, Inc. (GHI) a 1,566-home cooperative of circa 1930-1940 homes in Greenbelt, Maryland, undertook a multiyear pilot energy efficiency retrofit project. GHI established this pilot project as a basis for decision making for the rollout of a decade-long co...
Mallay, D. et al Home Innovation Research Labs National Association of Home Builders
Jul 21, 2016
4 Resources
0 Stars
In curation
4 Resources
0 Stars
In curation
Analysis of Joist Masonry Moisture Content Monitoring
BSC TO5 Task 7.2 Analysis of Joist Masonry Moisture Content Monitoring
House Lawrence, MA 01840
This work involved the field monitoring of embedded wood joist ends in a solid brick building in zone 5A that was retrofitted with interior insulation. Eleven joists throughout the bui...
Ueno, K. Building Science Corporation
Apr 27, 2016
3 Resources
0 Stars
In curation
3 Resources
0 Stars
In curation
Evaluation of Early Performance Results for Massachusetts Homes in the National Grid Pilot Deep Energy Retrofit Program
In 2009, National Grid started a DER pilot program that offered technical support and financial incentives to qualified Massachusetts homeowners who planned and successfully completed a retrofit that incorporated the performance requirements and goals of the National Grid DER meas...
Neuhauser, K. and Gates, C. Building Science Corporation
Apr 27, 2016
29 Resources
0 Stars
In curation
29 Resources
0 Stars
In curation